8.8. OUTDOOR FAN CONTROL
∙
Outdoor fan motor is controlled with 2 speeds. Fan is in operation when the compressor starts operation and stops 30 seconds
after compressor stops operation.
(During 80 seconds, Fan speed is at low).
Fan Speed
Compressor Operating Frequency
Cooling-Soft Dry
Heating
High
Over 45Hz
Over 73Hz
Low
Below 45Hz
Below 73Hz
8.9. AIRFLOW DIRECTION
∙
Blade angle setting (Upper limit reference)
Operation
Blade angle
1
2
3
4
5
heating
Airflow direction auto
Indoor heat exchanger
temperature
A
14°
B
61°
C
0°
Airflow direction manual
-
-
0°
18°
29.4°
45.1°
61°
Cooling
Airflow direction auto
-
0° - 37°
Anti-dew formation control
3° - 37°
Airflow direction manual
-
0°
8°
18°
28°
37°
Anti-dew formation control
3°
11.5°
20°
28.5°
37°
Dry
Airflow direction auto
-
0° - 37°
Anti-dew formation control
3° - 37°
Airflow direction manual
-
0°
8°
18°
28°
37°
Anti-dew formation control
3°
11.5°
20°
28.5°
37°
Stop
138°
∙
Sitting angle
1. Airflow Direction Manual
By pressing the remote control airflow direction setting switch, the blade will move to the indicated angle (1, 2, 3, 4, 5) as shown
in the table. When the remote control OFF/ON switch is pressed, the blade will move to the Close position.
2. Airflow Direction Auto
By setting the airflow direction to AUTO, the blade swings up and down from 0°-37° during Cooling and Soft Dry operation.
During Heating operation, the blade angle will shift according to the indoor heat exchanger temperature as shown below:
27
CS-VG120KE / CU-VG120KE
Содержание CS-VG120KE
Страница 3: ...2 Functions 2 1 REMOTE CONTROL 3 CS VG120KE CU VG120KE ...
Страница 4: ...2 2 INDOOR UNIT 4 CS VG120KE CU VG120KE ...
Страница 5: ...5 CS VG120KE CU VG120KE ...
Страница 6: ...2 3 OUTDOOR UNIT 6 CS VG120KE CU VG120KE ...
Страница 9: ...4 Dimensions 4 1 CS VG120KE INDOOR UNIT 9 CS VG120KE CU VG120KE ...
Страница 10: ...4 2 CU VG120KE OUTDOOR UNIT 10 CS VG120KE CU VG120KE ...
Страница 12: ...6 Block Diagram CS VG120KE CU VG120KE 12 ...
Страница 49: ...11 3 INDOOR OUTDOOR UNIT INSTALLATION DIAGRAM 49 CS VG120KE CU VG120KE ...
Страница 62: ...13 Technical Data 13 1 OPERATION CHARACTERISTICS 62 CS VG120KE CU VG120KE ...
Страница 68: ...CS VG120KE CU VG120KE 68 ...
Страница 69: ...15 Printed Circuit Board 15 1 CS VG120KE INDOOR UNIT 69 CS VG120KE CU VG120KE ...
Страница 70: ...70 CS VG120KE CU VG120KE ...
Страница 71: ...15 2 CU VG120KE OUTDOOR UNIT POWER SUPPLY 71 CS VG120KE CU VG120KE ...
Страница 72: ...MAIN INDICATOR 72 CS VG120KE CU VG120KE ...
Страница 73: ...16 Exploded View Replacement Parts List 16 1 CS VG120KE 16 1 1 Exploded View 73 CS VG120KE CU VG120KE ...
Страница 75: ...16 2 CU VG120KE 16 2 1 Exploded View 75 CS VG120KE CU VG120KE ...
Страница 78: ...MEMO ...
Страница 79: ...MEMO ...
Страница 80: ...Printed in Japan MS1299SO ...