8.4.7. Anti-Dew Formation Control
•
Purpose is to prevent dew formation on indoor unit air discharge area.
•
When room temperature is constant (±1°C) the following conditions occur for 30 minutes continuously, anti-dew formation will
activate:
−
Remote Control setting temperature is less than 25°C.
−
Compressor is on.
−
Cooling operation mode.
−
Indoor Fan motor operate at Low fan speed (CLo, Lo- or QLo).
•
This control is cancelled immediately when above condition is changed, or Powerful button is pressed.
•
Anti-Dew formation is control by:
1. CLo fan is changed to HLo fan.
2. QLo fan is changed to HLo fan.
8.5. Indoor Fan Speed Control
•
Indoor Fan Speed can be set using remote control.
8.5.1. Fan Speed Rotation Chart
Fan Speed (rpm)
CS-V7DKE
CS-V9DKE
CS-V12DKE
S Hi
1140
1250
1310
Hi
1050
1140
1280
Me
900
940
1080
H Lo
850
840
960
C Lo
780
750
870
Lo-
750
750
850
S Lo
710
710
820
SS Lo
-
-
-
Q S Hi
-
-
-
Q Hi
950
1040
1180
Q Me
800
840
980
Q H Lo
-
-
-
Q Lo
680
650
770
22
CS-V7DKE CU-V7DKE / CS-V9DKE CU-V9DKE / CS-V12DKE CU-V12DKE
Содержание CS-V12DKE
Страница 15: ...5 Refrigeration Cycle Diagram 15 CS V7DKE CU V7DKE CS V9DKE CU V9DKE CS V12DKE CU V12DKE ...
Страница 16: ...6 Block Diagram 16 CS V7DKE CU V7DKE CS V9DKE CU V9DKE CS V12DKE CU V12DKE ...
Страница 17: ...7 Wiring Diagram 17 CS V7DKE CU V7DKE CS V9DKE CU V9DKE CS V12DKE CU V12DKE ...
Страница 64: ...14 3 3 CS V12DKE CU V12DKE 64 CS V7DKE CU V7DKE CS V9DKE CU V9DKE CS V12DKE CU V12DKE ...
Страница 75: ...75 CS V7DKE CU V7DKE CS V9DKE CU V9DKE CS V12DKE CU V12DKE ...
Страница 77: ...19 2 Remote Control 77 CS V7DKE CU V7DKE CS V9DKE CU V9DKE CS V12DKE CU V12DKE ...
Страница 79: ...TOP VIEW 79 CS V7DKE CU V7DKE CS V9DKE CU V9DKE CS V12DKE CU V12DKE ...