75
15. Operation Control (For Multi Split Connection)
During multi split connection, indoor unit’s operation controls are same with single split connection unless specified in
this chapter.
15.1 Cooling
operation
15.1.1 Thermostat
control
Capability supply to indoor unit is OFF (Expansion valve closed) when Intake Air Temperature — Internal setting
temperature < -2.0°C.
Capability resume supply to indoor unit after waiting for 3 minutes, if the Intake Air temperature — Internal setting
temperature > Capability supply OFF point.
15.2 Soft Dry Operation
15.2.1 Thermostat
control
Capability supply to indoor unit is OFF (Expansion valve closed) when Intake Air Temperature
—
Internal setting
temperature < -3.0°C.
Capability resume to indoor unit after waiting for 3 minutes, if the Intake Air temperature
—
Internal setting
temperature > Capability supply OFF point.
15.3 Heating
Operation
15.3.1 Thermostat
control
Capability supply to indoor unit is OFF (Expansion valve closed) when Intake Air Temperature
—
Internal setting
temperature > +1.0°C.
During this condition, the indoor fan is stopped if compressor is ON.
Capability resume supply to indoor unit after waiting for 3 minutes, if the Intake Air Temperature
—
Internal
setting temperature < Capability supply OFF point.
15.3.2 Temperature Sampling Control
Temperature sampling is controlled by outdoor unit where room temperature for all power supply ON indoor unit
could be obtained.
When capability supply to the indoor unit is OFF and the compressor is ON, the indoor fan motor is stopped.
During this condition, 15 seconds after sampling signal from outdoor unit is received, the indoor fan start
operation at low fan speed.
However, within first 4 minutes of capability stopped supply to the indoor unit, even sampling signal is received,
the sampling control is cancelled.
Содержание CS-TZ60TKEW
Страница 25: ...25 8 Block Diagram 8 1 Indoor Unit FUSE 301 TEMP FUSE SC U 1 2 3 M INDOOR UNIT ...
Страница 32: ...32 11 1 2 Indicator Printed Circuit Board CN DISP LED206 LED205 LED203 LED201 LED204 LED202 ...
Страница 33: ...33 11 2 Outdoor Unit CN STM1 CN MTR1 CN MTR2 CN TANK CN TH1 CN HOT AC BLK DATA AC WHT POWER TRANSISTOR IPM ...
Страница 122: ...122 19 1 5 To Remove Control Board Figure 6 19 1 6 To Remove Cross Flow Fan and Indoor Fan Motor Figure 7 Figure 8 ...
Страница 123: ...123 Figure 9 Figure 10 ...