28
b. Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a.Powerful button is pressed.
b.Stop by OFF/ON switch.
c.Timer “off” activates.
d.Quiet button is pressed again.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, except ion only operation.
5. During quiet operation, if timer “on” activates, quiet operation maintains.
6. After off, when on back, quiet operation is not memorised.
C. Control contents
1. Auto fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
2. Manual fan speed for quiet operation is -1 step from setting fan speed.
12.3.1.
Quiet operation (Heating)
A. Purpose
To provide quiet heating operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
• When “quiet” button at remote control is pressed.
Quiet LED illuminates.
b. Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed.
b. Stop by OFF/ON switch.
c. Timer “off” activates.
d. Quiet button is pressed again.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode, expected ion only
operation.
5. During quiet operation, if timer “on” activates, quiet operation maintains.
6. After off, when on back, quiet operation is not memorised.
C. Control contents
a. Fan speed auto
1. Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.
Auto fan speed is changed from normal setting to quiet setting of respective fan speed.
This is to reduce sound of Hi, Me, Lo for 3dB.
b. Fan speed manual
1. Manual fan speed for quiet operation is -1 step from setting fan speed.
12.4. Powerful Mode Operation
A. Purpose
To achieve the setting temperature quickly.
B. Control Condition
a. Powerful operation start condition
When the “powerful” button at remote control is pressed, Powerful LED illuminates
b. Powerful operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a. Powerful button is pressed again
b. Quiet button is pressed
c. Stop by OFF/ON switch
d. Timer OFF is pressed again
Содержание CS-TE12HKE
Страница 8: ...8 5 Dimensions 5 1 Indoor Unit ...
Страница 9: ...9 5 2 Outdoor Unit ...
Страница 10: ...10 6 Refrigeration Cycle Diagram ...
Страница 11: ...11 7 Block Diagram ...
Страница 12: ...12 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Страница 13: ...13 8 2 Outdoor Unit ...
Страница 14: ...14 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Страница 15: ...15 9 2 Outdoor Unit ...
Страница 16: ...16 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Printed Circuit Board ...
Страница 17: ...17 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Страница 20: ...20 3 For the embedded piping This can be used for left rear piping and left bottom piping also ...
Страница 43: ...43 16 1 2 Removal of Electronic Controller ...
Страница 44: ...44 16 1 3 Removal of Control Board ...
Страница 45: ...45 16 1 4 Removal of Fan Motor and Cross Flow Fan ...
Страница 46: ...46 ...
Страница 48: ...48 17 Technical Data 17 1 Operation Characteristics ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 51: ...51 ...