background image

7

TROUBLESHOOTING

The following symptoms do not indicate malfunction.

The following symptoms do not indicate malfunction.

SYMPTOM

SYMPTOM

CAUSE

CAUSE

Mist emerges from indoor unit.

•  Condensation effect due to cooling process.

Water 

fl

 owing sound during operation.

• Refrigerant 

fl

 ow inside the unit.

The room has a peculiar odour.

•  This may be due to damp smell emitted by the wall, 

carpet, furniture or clothing.

Indoor fan stops occasionally during automatic fan speed 

setting.

•  This helps to remove the surrounding odours.

Operation is delayed a few minutes after restart.

•  The delay is a protection to the unit’s compressor.

Outdoor unit emits water/steam.

•  Condensation or evaporation occurs on pipes.

Timer indicator is always on.

•  The timer setting repeats daily once set.

Power indicator blinks before the unit is switched on.

•  This is a preliminary step in preparation for the operation 

when the ON timer has been set.

Cracking sound during operation. 

•  Changes of temperature cause the expansion/contraction 

of the unit.

Check the following before calling for servicing.

Check the following before calling for servicing.

SYMPTOM

SYMPTOM

CHECK

CHECK

Cooling operation is not working ef

fi

 ciently.

•  Set the temperature correctly.

•  Close all doors and windows.

•  Clean or replace the 

fi

 lters.

•  Clear any obstruction at the air inlet and air outlet vents.

Noisy during operation.

•  Check if the unit has been installed at an incline.

•  Close the front panel properly.

Remote control does not work.

(Display is dim or transmission signal is weak.)

•  Insert the batteries correctly.

•  Replace weak batteries.

The unit does not work.

•  Check if the circuit breaker is tripped.

•  Check if timers have been set.

The unit does not receive the signal from the remote 

control.

•  Make sure the receiver not obstructed.

• Certain 

fl

 uorescent lights may interfere with signal 

transmitter. Please consult authorized dealer.

The unit stops and the timer indicator blinks.

Use remote control to retrieve error code.

CANCEL

TIMER

ON

OFF

1

2

SET

3

SET

CHECK

CLOCK

RESET

AC

RC

1

Press for 5 

seconds.

3

Press for 5 

seconds to 

quit checking.

2

Press until you hear 

beep sound, then 

write down the error 

code.

Note:

•  For certain errors, you 

may restart the unit for 

limited operation with 4 

beeps during operation 

starts.

4

  Turn the unit off and reveal the error code to authorized dealer.

Содержание CS-S9LKR

Страница 1: ...on of law F567537 Operating Instructions Air Conditioner Model No Indoor Unit Outdoor Unit CS S9LKR CU S9LKR CS S12LKR CU S12LKR CS S24LKR CU S24LKR CS S28LKR CU S28LKR QUICK GUIDE QUICK GUIDE Before operating the unit read these operating instructions thoroughly and keep them for future reference ...

Страница 2: ... appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Please consult authorized dealer or s...

Страница 3: ...s strongly recommended to be installed with Earth Leakage Circuit Breaker ELCB or Residual Current Device RCD to prevent electric shock or fire This equipment must be earthed to prevent electrical shock or fire Prevent electric shock by switching off the power supply when Before cleaning or servicing Extended non use Abnormally strong lightning activity INFORMATION FOR SEASONAL INSPECTION AFTER EX...

Страница 4: ...ains to screen off sunlight and outdoor heat to reduce power consumption during cool mode DRY mode To dehumidify the environment Unit operates at low fan speed to give a gentle cooling operation 4 TO SELECT FAN SPEED 5 OPTIONS FAN SPEED For AUTO the indoor fan speed is automatically adjusted according to the operation mode Maximum distances 8m S9LKR S12LKR INDICATOR POWER Green TIMER Orange QUIET ...

Страница 5: ... SET Upcoming timer will be displayed and will be activated in sequence When ON Timer is set the unit may start earlier up to 15 minutes before the actual set time in order to achieve the desired temperature on time Timer operation is based on the clock set in the remote control and repeats daily once set For clock setting please refer to Remote Control Preparation at back cover 8 TO SWITCH BETWEE...

Страница 6: ...ter filter It is recommended to clean the filter every 6 months Replace the filter every 3 years or replace any damaged filter Part no CZ SA14P 9 AIR FILTERS Air filter cleaning is required every two weeks Wash rinse the filters gently with water to avoid damage to the filter surface Dry the filters thoroughly under the shade away from fire or direct sunlight Replace any damaged filters CAUTION Sw...

Страница 7: ...cing Check the following before calling for servicing SYMPTOM SYMPTOM CHECK CHECK Cooling operation is not working efficiently Set the temperature correctly Close all doors and windows Clean or replace the filters Clear any obstruction at the air inlet and air outlet vents Noisy during operation Check if the unit has been installed at an incline Close the front panel properly Remote control does n...

Страница 8: ...formation on Disposal in other Countries outside the European Union These symbols are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Note for the battery symbol bottom two symbol examples This symbol might be used in combination with a chemical symbol In this case it complies with the re...

Отзывы: