8
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.70 (1/2)
6.35 (1/4) / 15.88 (5/8)
Standard length
m (ft)
5.0 (16.4)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 20 (65.6)
3 (9.8) ~ 20 (65.6)
I/D & O/D Height different
m (ft)
15 (49.2)
15 (49.2)
Additional Gas Amount
g/m (oz/ft)
15 (0.2)
20 (0.2)
Piping
Length for Additional Gas
m (ft)
10 (32.8)
10 (32.8)
Inner Diameter
mm
16
16
Drain Hose
Length mm
550
550
Fin Material
Aluminium (Pre coated)
Aluminium (Pre coated)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 15 x 17
2 x 15 x 17
Indoor Heat
Exchanger
Size (W x H x L)
mm
810 x 315 x 25.4
810 x 315 x 25.4
Fin Material
Aluminium (Blue coated)
Aluminium (Blue coated)
Fin Type
Slit Fin
Slit Fin
Row x Stage x FPI
2 x 24 x 17
1 x 31 x 19
Outdoor
Heat
Exchanger
Size (W x H x L)
mm
25.4 x 504 x 693.4:713.4
12.7 x 651.0 x 868.0
Material
Polypropelene
Polypropelene
Air Filter
Type
One-touch
One-touch
Power Supply
Indoor
Indoor
Power Supply Cord
A
15
20
Thermostat
-
-
Protection Device
-
-
DRY BULB
WET BULB
DRY BULB
WET BULB
Maximum
32 23 32 23
Indoor Operation Range
Minimum
16 11 16 11
Maximum
43 26 43 26
Outdoor Operation Range
Minimum
16 11 16 11
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)
Содержание CS-PS9NKV
Страница 9: ...9 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 10: ...10 4 Dimensions 4 1 Indoor Unit 4 1 1 CS PS9NKV CS PS12NKV...
Страница 11: ...11 4 1 2 CS PS18NKV CS PS24NKV...
Страница 12: ...12 4 2 Outdoor Unit 4 2 1 CU PS9NKV 4 2 2 CU PS12NKV CU PS18NKV...
Страница 13: ...13 4 2 3 CU PS24NKV...
Страница 14: ...14 5 Refrigeration Cycle Diagram 5 1 CS PS9NKV CU PS9NKV CS PS12NKV CU PS12NKV...
Страница 15: ...15 5 2 CS PS18NKV CU PS18NKV CS PS24NKV CU PS24NKV...
Страница 16: ...16 6 Block Diagram 6 1 CS PS9NKV CU PS9NKV...
Страница 17: ...17 6 2 CS PS12NKV CU PS12NKV...
Страница 18: ...18 6 3 CS PS18NKV CU PS18NKV...
Страница 19: ...19 6 4 CS PS24NKV CU PS24NKV...
Страница 20: ...20 7 Wiring Connection Diagram 7 1 Indoor Unit 7 1 1 CS PS9NKV CS PS12NKV...
Страница 21: ...21 7 1 2 CS PS18NKV CS PS24NKV...
Страница 26: ...26 8 Electronic Circuit Diagram 8 1 Indoor Unit 8 1 1 CS PS9NKV CS PS12NKV...
Страница 27: ...27 8 1 2 CS PS18NKV CS PS24NKV...
Страница 28: ...28 8 2 Outdoor Unit 8 2 1 CU PS9NKV...
Страница 29: ...29 8 2 2 CU PS12NKV...
Страница 30: ...30 8 2 3 CU PS18NKV...
Страница 31: ...31 8 2 4 CU PS24NKV...
Страница 32: ...32 9 Printed Circuit Board 9 1 Indoor Unit 9 1 1 Main Printed Circuit Board 9 1 1 1 CS PS9NKV CS PS12NKV...
Страница 33: ...33 9 1 1 2 CS PS18NKV CS PS24NKV 9 1 2 Indicator and Receiver Printed Circuit Board...
Страница 34: ...34 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU PS9NKV...
Страница 35: ...35 9 2 1 2 CU PS12NKV...
Страница 36: ...36 9 2 1 3 CU PS18NKV...
Страница 37: ...37 9 2 1 4 CU PS24NKV...
Страница 38: ...38 9 2 2 Noise Filter Printed Circuit Board 9 2 2 1 CU PS9NKV...
Страница 86: ...86 Figure 13 Figure 14 15 2 3 To remove discharge grille Figure 15...
Страница 88: ...88 Figure 19 Figure 20...