45
10.2.4 Connect the Cable to the Indoor Unit
The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.
1 Install the indoor unit on the installing holder that mounted on the wall,
2 Open the front panel and grille door by loosening the screw.
3 Cable connection to the power supply through Isolating Devices (Disconnecting means).
o
Connect the approved polychloroprene sheathed
power supply cord
3 x 1.5 mm
2
(1.0~1.5HP) or 3 x
2.5 mm
2
(2.0~2.5HP), type designation 245 IEC 57 or heavier cord to the terminal board, and connect
the other end of the cable to Isolating Devices (Disconnecting means).
o
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or
otherwise) is too short.
o
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air
conditioner shall be done by using approved socket and plug rated 15/16A (1.0~1.5HP) or 16A (2.0HP)
or 20A (2.5HP). Wiring work to both socket and plug must follow to national wiring standard.
4 Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.
5
Connection cable
between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 x
1.5 mm
2
(1.0 ~ 1.5HP) or 4 x 2.5 mm
2
(2.0 ~ 2.5HP) flexible cord, type designation 245 IEC 57 or heavier
cord. Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or
otherwise) is too short.
6 Bind all the indoor and outdoor connection cable with tape and route the connecting cable via the right
escapement.
Содержание CS-PS9NKH
Страница 13: ...13 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Страница 14: ...14 4 Dimensions 4 1 Indoor Unit 4 1 1 CS PS9NKH CS PS12NKH CS PS18NKH...
Страница 15: ...15 4 1 2 CS PS24NKH...
Страница 16: ...16 4 2 Outdoor Unit 4 2 1 CU PS9NKH CU PS12NKH 4 2 2 CU PS18NKH...
Страница 17: ...17 4 2 3 CU PS24NKH...
Страница 18: ...18 5 Refrigeration Cycle Diagram 5 1 CS PS9NKH CU PS9NKH CS PS12NKH CU PS12NKH...
Страница 19: ...19 5 2 CS PS18NKH CU PS18NKH CS PS24NKH CU PS24NKH...
Страница 20: ...20 6 Block Diagram 6 1 CS PS9NKH CU PS9NKH...
Страница 21: ...21 6 2 CS PS12NKH CU PS12NKH...
Страница 22: ...22 6 3 CS PS18NKH CU PS18NKH...
Страница 23: ...23 6 4 CS PS24NKH CU PS24NKH...
Страница 24: ...24 7 Wiring Connection Diagram 7 1 Indoor Unit 7 1 1 CS PS9NKH CS PS18NKH CS PS24NKH...
Страница 25: ...25 7 1 2 CS PS12NKH...
Страница 30: ...30 8 Electronic Circuit Diagram 8 1 Indoor Unit 8 1 1 CS PS9NKH CS PS18NKH CS PS24NKH...
Страница 31: ...31 8 1 2 CS PS12NKH...
Страница 32: ...32 8 2 Outdoor Unit 8 2 1 CU PS9NKH...
Страница 33: ...33 8 2 2 CU PS12NKH...
Страница 34: ...34 8 2 3 CU PS18NKH...
Страница 35: ...35 8 2 4 CU PS24NKH...
Страница 37: ...37 9 1 1 2 CS PS12NKH 9 1 2 Indicator Printed Circuit Board...
Страница 38: ...38 9 2 Outdoor Unit 9 2 1 Main Printed Circuit Board 9 2 1 1 CU PS9 12NKH...
Страница 39: ...39 9 2 1 2 CU PS18NKH...
Страница 40: ...40 9 2 1 3 CU PS24NKH...
Страница 41: ...41 9 2 2 Noise Filter Printed Circuit Board 9 2 2 1 CU PS9NKH CU PS12NKH...
Страница 47: ...47 10 2 5 Wire Stripping And Connecting Requirement...
Страница 90: ...90 15 2 3 To remove power electronic controller Figure 13 Figure 14 15 2 4 To remove discharge grille Figure 15...
Страница 92: ...92 Figure 19 Figure 20...