Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical
shock or fire.
Use the specified cable (1.5mm ) and connect tightly for indoor/outdoor connection.
Power supply connection to a circuit breaker for the permanent connection. Use an approved 10A circuit breaker for the
permanent connection. lt must be a double pole switch with a minimum 3 mm contact gap.
The unit must be earthed, or it will cause fire or electric shock.
2
9
Installation
WARNING
9.1.
Before Installation
INDOOR UNIT
OUTDOOR UNIT
SELECT THE BEST LOCATION
There should not be any heat source or steam near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit shall be at least 2.5m.
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is
not obstructed.
There should not be any animal or plant which could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
Do not place any obstacles which may cause a short circuit of the discharged air.
If piping length is over the common length, additional refrigerant should be added.
4
2
1
1
3
5
1
1
No .
Accessories parts
Qty
2
Installation plate
Installation plate fixing screw
Remote controller
Battery
*
hr
DE
LA
Y
O
FF
ON
AUT
O
AUT
O
FA
N
SPEED
AIR
SWING
MODE
TEMP
OFF/ON
TIMER
ON
SET
AIR
S
WING
OFF
CANCEL
FA
N
S
PEED
AUT
O
COOL
DR
Y
FA
N
OFF
STD
.
Attached accessories
.
5
6
Drain elbow
(Only for models:
PA7DKD,PA9DKD)
CS-PA7DKD / CU-PA7DKD / CS-PC7DKD / CU-PC7DKD