![Panasonic CS-MKS12NKU Скачать руководство пользователя страница 100](http://html.mh-extra.com/html/panasonic/cs-mks12nku/cs-mks12nku_technical-and-service-manual_1507810100.webp)
4
1. General
This booklet briefly outlines where and how to install the
air conditioning system. Please read over the entire set
of instructions for the indoor and outdoor units and make
sure all accessory parts listed are with the system before
beginning.
1-1. Tools Required for Installation (not supplied)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Carpenter’s level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits
9. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for deburring)
1-2. Accessories Supplied with Unit
Table 1
1-3. Optional Copper Tubing Kit
Copper tubing for connecting the outdoor unit to the
indoor unit is available in kits which contain the narrow
and wide tubing, fittings and insulation. Consult your
nearest sales outlet or air conditioning workshop.
1-4. Type of Copper Tube and Insulation Material
If you wish to purchase these materials separately from
a local source, you will need:
1.
Deoxidized annealed copper tube for refrigerant tub-
ing as detailed in Table 2.
Cut each tube to the appropriate lengths 1' to 1'4"
(30 cm to 40 cm) to dampen vibration between units.
Table 2
2.
Foamed polyethylene insulation for the specified
copper tubes as required to precise length of tubing.
Wall thickness of the insulation should be not less
than 5/16" (8 mm).
3.
Use insulated copper wire for field wiring. Wire size
varies with the total length of wiring. Refer to 3-6.
Wiring Instructions for details.
Part s Fi
gure
Q’ty
Parts Fi
gure
Q’ty
1
1
1
Rawl pl ug
Tappi ng s crew
Tr uss-head
Phillips
5
/
32
5
/
8
" (4 16 mm)
2
AAA alkali ne
battery
10
8
Part s Fi
gure
Q’ty
Remote
controller
Remote co ntrol
holder
Drain hose
adapter
Packed in the indoor unit.
1
Clamp
CAUTION
Check local electrical codes
and regulations before
obtaining wire. Also, check
any specified instructions or
limitations.
Model
Narrow Tube
Wide Tube
Outer Dia.
Thickness
Outer Dia.
Thickness
CS-MKS7NKU
1/4" (6.35 mm)
0.0314" (0.8 mm)
3/8" (9.52 mm)
0.0314" (0.8 mm)
CS-MKS9NKU
1/4" (6.35 mm)
0.0314" (0.8 mm)
3/8" (9.52 mm)
0.0314" (0.8 mm)
CS-MKS12NKU
1/4" (6.35 mm)
0.0314" (0.8 mm)
3/8" (9.52 mm)
0.0314" (0.8 mm)
CS-MKS18NKU
1/4" (6.35 mm)
0.0314" (0.8 mm)
1/2" (12.70 mm)
0.0314" (0.8 mm)
CS-MKS24NKU
1/4" (6.35 mm)
0.0314" (0.8 mm)
5/8" (15.88 mm)
0.0393" (1.0 mm)
Содержание CS-MKS12NKU
Страница 23: ...3 DIMENSIONAL DATA Indoor Unit CS MKS7NKU CS MKS9NKU CS MKS12NKU Unit inch mm 852 0 0010 215 00 0 23 ...
Страница 24: ...Unit inch mm Indoor Unit CS MKS18NKU CS MKS24NKU CS MKS18NKU CS MKS24NKU 852 0 0010 216 00 0 24 ...
Страница 43: ......
Страница 44: ...Operating Instructions CS MKS7NKU CS MKS9NKU CS MKS12NKU APPENDIX A 852 6 4181 214 00 2 A 1 ...
Страница 70: ...Operating Instructions CS MKS18NKU CS MKS24NKU 852 6 4181 215 00 1 APPENDIX B A 2 ...
Страница 117: ......
Страница 118: ...DC1111 0 ...