background image

4

AIR SWI

NG

FAN SPE

ED

MODE

TEMP

OFF/ON

TIMER

SET

CANCEL

ON

OFF

1

2

3

SET

CLOCK

RESET

OFF

TIMER

ON

TIMER

FAN

SPEED

AIR

SWING

AUTO

COOL

DRY

AUTO

COMFORT

ECONAVI

REMOTE CONTROL

3

4

5

8

9

7

10

2

11

Press the remote control’s button

1

TO TURN ON OR OFF THE UNIT

•  Please be aware of the OFF indication on the remote 

control display to prevent the unit from starting/stopping 

improperly.

2

 

TO SET TEMPERATURE

•  For cool and dry modes, the range of temperature for 

selection is 16°C ~ 30°C.

•  Operating the unit within the recommended temperature 

could induce energy saving.

COOL mode : 26

˚

C ~ 28

˚

C.

DRY mode : 1

˚

C ~ 2

˚

C lower than room temperature.

3

TO SELECT OPERATION MODE

AUTO mode - For your convenience

•  Unit selects the operation mode according to the room 

temperature.

•  Once auto mode is selected, the unit will operate at the 

standard setting temperature.

Room 

temperature

Operation mode

Standard setting 

temperature

23

˚

C & above

Cool

25

˚

C

Below 23

˚

C

Dry

22

˚

C

• Press   for “HI” to +2

˚

C or 

 for “LO” to -2

˚

C to the 

standard setting temperature.

COOL mode - To enjoy cool air

•  Use curtains to screen off sunlight and outdoor heat to 

reduce power consumption during cool mode.

DRY mode - To dehumidify the environment

•  Unit operates at low fan speed to give a gentle cooling 

operation.

4

TO SELECT FAN SPEED (3 OPTIONS)

FAN SPEED

•  For AUTO, the indoor fan speed is automatically adjusted 

according to the operation mode.

5

TO ADJUST VERTICAL AIRFLOW DIRECTION 

(5 OPTIONS)

AIR SWING

•  Keeps the room ventilated.

•  In COOL/DRY mode, if AUTO is set, the louver swing 

up/down automatically.

Remote 
Control display

6

1

Maximum 

distance: 8m

Human activity 

sensor

INDICATOR

 

POWER

(Green)

 

TIMER

(Orange)

 

ECONAVI/
AUTO COMFORT

(Green)

Содержание CS-KC9NKH-3

Страница 1: ...CU KC9NKH 3 CS KC12NKH 3 CU KC12NKH 3 QUICK GUIDE QUICK GUIDE ENGLISH Before operating the unit read these operating instructions thoroughly and keep them for future reference Panasonic Appliances Air Conditioning Malaysia Sdn Bhd 2012 Unauthorized copying and distribution is a violation of law ...

Страница 2: ...er or specialist to clean the internal parts repair install remove and reinstall the unit Improper installation and handling will cause leakage electric shock or fire Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product damage burst and injury etc Do not install the unit in a potentially explosive or ...

Страница 3: ...ted following the polarity stated POWER SUPPLY Do not pull the cord to disconnect the plug to prevent electric shock WARNING WARNING REMOTE CONTROL Do not allow infants and small children to play with the remote control to prevent them from accidentally swallowing the batteries POWER SUPPLY Do not use a modified cord joint cord extension cord or unspecified cord to prevent overheating and fire To ...

Страница 4: ...he room temperature Once auto mode is selected the unit will operate at the standard setting temperature Room temperature Operation mode Standard setting temperature 23 C above Cool 25 C Below 23 C Dry 22 C Press for HI to 2 C or for LO to 2 C to the standard setting temperature COOL mode To enjoy cool air Use curtains to screen off sunlight and outdoor heat to reduce power consumption during cool...

Страница 5: ...mal High Low None Set Fan Speed Medium Fan 1 tap 2 C 1 C 1 C 1 tap COOL DRY Mode Set Temperature For first 15 minutes or until set temperature is reached The human activity sensor may not detect moving objects further than 7m away or beyond detection angle The human activity sensor sensitivity is influenced by indoor unit location movement speed temperature range etc The human activity sensor may ...

Страница 6: ...by hand 8 AUTO OFF ON BUTTON Use when remote control is misplaced or a malfunction occurs Action Mode Press once Auto Press and hold until 1 beep is heard then release Cooling Press the button to turn off 9 ANTI BACTERIAL FILTER Anti bacterial filter Clean the filter whenever necessary Wash rinse the filter gently with water to avoid damage to the filter Dry the filter thoroughly under shade away ...

Страница 7: ...icate malfunction SYMPTOM SYMPTOM CAUSE CAUSE Mist emerges from indoor unit Condensation effect due to cooling process Water flowing sound during operation Refrigerant flow inside the unit The room has a peculiar odor This may be due to damp smell emitted by the wall carpet furniture or clothing Indoor fan stops occasionally during automatic fan speed setting This helps to remove the surrounding o...

Страница 8: ... Remote Control Preparation 1 2 3 TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET 4 5 6 1 Pull out 2 Insert AAA or R03 batteries can be used 1 year 3 Close the cover 4 Press CLOCK 5 Set time 6 Confirm QUICK GUIDE AIR SWING FAN SPEED MODE TEMP OFF ON TIMER SET CANCEL ON OFF 1 2 3 SET CLOCK RESET OFF TIMER ON TIMER FAN SPEED AIR SWING AUTO COOL DRY AUTO COMFORT ECONAVI 2 1 3 Printed in Malaysia F56840...

Отзывы: