33
Rear view for left piping installation
Drain cap
Drain hose
•
How to pull the piping and drain hose out, in case
of the embedded piping.
PVC tube
for drain
hose
Indoor unit
100 mm
Piping
Cable
Apply putty or
caulking material
to seal the wall
opening.
Connection
cable
Piping
More
than
470 m
m
Mo
re t
han
950
mm
PVC tube (VP-65)for piping
and connection cable
PVC tubefor drain hose (VP-30)
PVC tube for
drain hose (VP-20)
Mo
re
tha
n
70
0 mm
•
In case of left piping how to insert
the connection cable and drain hose.
Drain hose
from main unit
Cable
45°
Drain
hose
Piping
(For the right piping, follow the
same procedure)
Sleeve for piping hole
Drain hose
Piping
Connection cable
More than 950 mm
Replace the drain hose
12.2.4 Connect the Cable to the Indoor Unit
1. The inside and outside connection cable can be connected without removing the front grille.
2. Decide on the type of power supply connection to be used, indoor power supply or outdoor power supply.
12.2.4.1 In case of indoor power supply
3. Install the indoor unit on the installing holder that mounted on the wall.
4. Open the front panel and grille door by loosening the screw.
5. Cable connection to the power supply through Isolating Devices (Disconnecting means).
Connect approved type polychloroprene sheathed
power supply cord
3 × 1.5mm
2
type designation 60245
IEC 57 or heavier cord to the terminal board, and connect the others end of the cord to Isolating Devices
(Disconnecting means).
Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or otherwise)
is too short.
In unavoidable case, joining of power supply cord between isolating devices and terminal board of air
conditioner shall be done by using approved socket and plug with earth pin rated 16A. Wiring work to both
socket and plug must follow to national wiring standard.
6. Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.