![Panasonic CS-HZ25TKE Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/panasonic/cs-hz25tke/cs-hz25tke_service-manual_256966065.webp)
65
14.4.1 Vertical
Airflow
Operation Mode
Airflow Direction
Upper Vane Angle (°)
Lower Vane Angle (°)
1 2 3 4 5 1 2 3 4 5
Heating
Auto with Heat
Exchanger
Temperature
A 25
17
B 55
37
C 25
17
Summer House
55
37
Manual
20 45 55 65 70 17 27 37 47 56
Cooling and Fan
Auto
45 ~ 70
2 ~ 39
Manual
20 25 50 55 70 2 7 17 27 39
Soft Dry
Auto
45 ~ 70
2 ~ 39
Manual
20 25 50 55 70 2 7 17 27 39
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the
angles as stated above. For heating mode operation, the angle of the vane depands on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop. When the air conditioner is
stopped using remote control, the vane will shift to close position.
2. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and
the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the
vane will shift to close position.
58°C
50°C
Indoor Heat
Exchanger Temperature
36°C
30°C
C
A
Figure 1
B
Figure 2
Upper vane: 60°
Lower vane: 58°
Reference point
Closed Position
Step 1
Step 2
Step 3
Step 4
Step 5
14.4.2 Horizontal
Airflow
1. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the
angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat
exchanger temperature as Figure 1 below. It does not swing during fan motor stop.
Operation Mode
Vane Angle (°)
Heating, with heat exchanger temperature
A
65 ~ 115
B 90
Cooling, Fan and Soft Dry
65 ~ 115
Figure 2
Figure 1
Indoor Heat Exchanger
Temperature
A: swing
B: fix front
40°C
43°C
Top View
0°
1
5
2
3
4