5
2. Specifications
MODEL
INDOOR CS-E9SD3UAW
OUTDOOR CU-E9SD3UA
Performance Test Condition
ARI
Power Supply
Phase, Hz
Single, 60
V 208
230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW
1.20 2.64 3.00 1.20 2.64 3.00
BTU/h
4100 9000 10200 4100 9000 10200
Running
Current
A
- 3.6 - - 3.2 -
Input
Power
W
250 690 850 250 690 850
EER
W/W 4.80 3.82 3.53 4.80 3.82 3.53
BTU/hW 16.40 13.00 12.00 16.40 13.00 12.00
Power
Factor
%
- 92 - - 94 -
Indoor Noise (H / L / QLo)
dB-A
35 / 28 / 25
35 / 28 / 25
Power Level dB
51 / - / -
51 / - / -
Outdoor Noise (H / L / QLo)
dB-A
48 / - / -
48 / - / -
Power Level dB
63 / - / -
63 / - / -
Heating
Capacity
kW
1.20 3.51 4.14 1.20 3.51 4.14
BTU/h
4100 12000 14100 4100 12000 14100
Running
Current
A
- 5.7 - - 5.1 -
Input
Power
W
200 1.12k 1.50k 200 1.12k 1.50k
COP
W/W 6.00 3.12 2.76 6.00 3.12 2.76
BTU/hW 20.50 10.70 9.40 20.50 10.70 9.40
Power
Factor
%
- 96 - - 97 -
Indoor Noise (H / L / QLo)
dB-A
35 / 28 / 25
35 / 28 / 25
Power Level dB
51 / - / -
51 / - / -
Outdoor Noise (H / L / QLo)
dB-A
50 / - / -
50 / - / -
Power Level dB
65 / - / -
65 / - / -
Min Circuit Ampacity
15.00
Max. Overcurrent Protection
15.00
Max Current (A) / Max Input Power (W)
7.0 / 1.57k
Starting Current (A)
5.70
SEER/HSPF
20.50 / 10.00