26
11.2. Indoor Unit
11.2.1.
How to Fix Installation Plate
The mounting wall is strong and solid enough to prevent it from
the vibration.
The centre of installation plate should be at more than at
right and left of the wall.
The distance from installation plate edge to ceiling should more
than .
From installation plate left edge to unit’s left side is .
From installation plate right edge to unit’s right is .
B
: For left side piping, piping connection for liquid should be
about from this line.
: For left side piping, piping connection for gas should be
about from this line.
1. Mount the installation plate on the wall with 5 screws or
more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
• Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
• Line according to the left and right side of the installation
plate. The meeting point of the extended line is the
center of the hole. Another method is by putting
measuring tape at position as shown in the diagram
above. The hole center is obtained by measuring the
distance namely 128 mm for left and right hole
respectively.
• Drill the piping hole at either the right or the left and the
hole should be slightly slanting to the outdoor side.
11.2.2.
To Drill a Hole in the Wall and Install
a Sleeve of Piping
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the
wall.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
11.2.3.
Indoor Unit Installation
Model
Dimension
E7***, XE7***
E9***, XE9***
E12***, XE12***
E15***, XE15***
485 mm 82 mm 165 mm 158 mm 43 mm
95 mm
E18***, XE18***
E21***, XE21***
E24***, E28***
585 mm 82 mm 165 mm 158 mm 169 mm 219 mm
Caution
When the wall is hollow, please be sure to use the sleeve
for tube ass’y to prevent dangers caused by mice biting
the connecting cable.
Содержание CS-E24LKES
Страница 9: ...9 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 10: ...10 5 Dimensions 5 1 Indoor Unit Remote Control ...
Страница 11: ...11 5 2 Outdoor Unit ...
Страница 12: ...12 6 Refrigeration Cycle Diagram ...
Страница 13: ...13 7 Block Diagram ...
Страница 14: ...14 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Страница 15: ...15 8 2 Outdoor Unit 8 2 1 CU E24LKE ...
Страница 16: ...16 8 2 2 CU E28LKE ...
Страница 17: ...17 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Страница 18: ...18 9 2 Outdoor Unit 9 2 1 CU E24LKE ...
Страница 19: ...19 9 2 2 CU E28LKE ...
Страница 20: ...20 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Страница 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Страница 24: ...24 10 2 2 Power Printed Circuit Board ...
Страница 90: ...90 16 1 3 To remove power electronic controller ...
Страница 91: ...91 16 1 4 To remove discharge grille 16 1 5 To remove control board ...
Страница 92: ...92 16 1 6 To remove cross flow fan and indoor fan motor ...
Страница 93: ...93 ...
Страница 107: ...107 18 2 Outdoor Unit 18 2 1 CU E24LKE ...