background image

8

TIMER

ON

1

2

3

OFF

SET

CANCEL

AC

RC

SET

CLOCK

CHECK

RESET

AUTO 

HEAT 

FAN 
SPEED

AIR

SWING

COOL 

DRY 

TEMP 

AIR SWING 

FAN SPEED 

QUIET 

POWERFUL 

TIMER

ON

1

2

3

OFF

SET 

CANCEL 

MODE

OFF/ON

AC

RC

SET 

CLOCK

CHECK

RESET 

TIMER

  The timer is valid only when the clock is set correctly. 

  You can set your preferred time for ON and OFF timers.

The unit will turn ON or OFF automatically. 

  To cancel ON or OFF timer, press 

/.

 or 

OFF

, then 

press 

#!.#%,

.

C

SET  CH

G

SPEE

1

1

Select ON or 
OFF timer.

CANCEL

Cancel the 
selected timer.

2

2

Set the 
desired time.

2

Con

fi

 rm the 

setting.

3

3

 

Operation Details

•  The timer allows you to turn the air 

conditioner on or off automatically.

•  The unit may start in preliminary 

operation before the actual set time 
when ON timer has been set.

•  The set timer repeats daily once 

set.

•  If there is a power failure, you can 

restore the previous setting (once 
power is resumed) by pressing the     

SET

button.

•  If the timer is cancelled, press 

SET

       

to restore the previous setting.

 

Hints

•  Press and hold the 

CLOCK

 for 

approximately 5 seconds to set 
either 12-hour (am/pm) or 24-hour 
time indication. 

•  To dim the indicator display:

•  To switch the temperature setting 

to °C or °F, press and hold 

 

for approximately 10 seconds.

Press and hold for 
5 seconds.
To cancel, press 
the 

 again for 

5 seconds.

T C

Troubleshooting

  Timer indicator always on.

  The timer setting repeats daily once set.

  Remote control does not work.

  The batteries are inserted incorrectly or need replacing.

  The unit does not work.

  The circuit breaker is tripped or the timer is set incorrectly.

  Power indicator blinks before the unit is switched on.

  This is a preliminary step in preparation for the operation when the ON 

timer has been set.

Содержание CS-E18FKR

Страница 1: ...roughly and keep them for future reference Manufactured by Panasonic HA Air Conditioning M Sdn Bhd Lot 2 Persiaran Tengku Ampuan Section 21 Shah Alam Industrial Site 40300 Shah Alam Selangor Malaysia 2006 Panasonic HA Air Conditioning M Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law QUIET POWERFUL TIMER POWER ...

Страница 2: ...d small children to play with the remote control to prevent them from accidentally swallowing the batteries Do not install remove and reinstall the unit by yourself improper installation will cause leakage electric shock or fire Please consult an authorized dealer or specialist for the installation work This equipment must be earthed and installed with ELCB It may cause electrical shock or fire in...

Страница 3: ...oduct please contact your installer dealer or local authority and ask for the correct method of disposal E Environmental Requirements nvironmental Requirements End of Life Disposal End of Life Disposal The appliance is not intended for use by young children or the infirm person without supervision Young children should be supervised to ensure that they do not play with the appliance Use this air c...

Страница 4: ... beeps then release Heating To turn off press the AUTO OFF ON button again In the event of an error the unit will stop and the timer indicator will blink 2 Press until you hear beep sound then jot down the error code Notes The unit may be operable with 4 beeps on a limited basis depending on the error FF SET 3 Press for 5 seconds to quit checking 4 Turn the unit off and reveal the error code to yo...

Страница 5: ...set correctly Make sure windows and doors are closed Make sure filters are cleaned and replaced Make sure inlet and outlet vents are cleared Water flowing sound during operations Cause by refrigerant flow inside the unit The power indicator blinks during the operation and the indoor fan is stopped The unit is in defrost mode and the melted frost is drained from the outdoor unit Operation Details C...

Страница 6: ...g Indoor fan stops occasionally during automatic fan speed setting This helps to remove the surrounding odours Indoor fan stops occasionally during heating operation To avoid unintended cooling effect If automatic vertical airflow direction has been set the louvers swing up and down automatically For HEATING operation the air blows horizontally for a while then starts to blow downwards Keeps the r...

Страница 7: ...les powerful operation POWERFUL Hint To reduce power consumption during cooling operation close the curtains to prevent the sunlight and heat from coming in Operation Details To reach the desired set temperature quickly POWERFUL To provide a quiet surrounding QUIET Troubleshooting Noisy during operation The unit may have been installed at an incline or the front panel is not closed properly Operat...

Страница 8: ...en set The set timer repeats daily once set If there is a power failure you can restore the previous setting once power is resumed by pressing the SET button If the timer is cancelled press SET to restore the previous setting Hints Press and hold the CLOCK for approximately 5 seconds to set either 12 hour am pm or 24 hour time indication To dim the indicator display To switch the temperature setti...

Страница 9: ... recommended to vacuum the filters every 6 months For best perfomance place the deodorizing filter under direct sunlight for at least six hours every six months Replace the filter every 3 years or replace any damaged filters Part no CZ SAD13P For extended non use Activate heating for 2 3 hours to thoroughly dry the unit Turn off the power supply Remove the remote control batteries Vacuum wash and ...

Страница 10: ...NDED NON USE Checking of remote control batteries No obstruction at inlet and outlet vents After 15 minutes of operation it is normal to have the following temperature difference between inlet and outlet vents Cooling 8 C Heating 14 C ...

Страница 11: ... conditions Abnormal noise during operation Circuit breaker switches off frequently Water foreign particles have entered the Remote Control Power cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly NON SERVICEABLE CRITERIAS ...

Страница 12: ...Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F565372 Printed in Malaysia OPSC0606 01 ...

Отзывы: