CARE & CLEANING

Raise and pull to remove. 
Wash and dry.

Wipe gently.

Vacuum, wash and dry.

Clean with cotton 
bud.

Remove

Remove

Vacuum the super 
alleru-buster 

fi

 lter.

Vacuum, wash and 
dry the frame.

Remove

•  Wipe the unit gently with a soft, dry 

cloth.

INDOOR UNIT

• Air 

fi

 lters cleaning is needed every 

two weeks.

• Replace any damaged 

fi

 lters.

  Part no: CWD001144

AIR FILTER

•  It is recommended to clean this 

fi

 lter 

every 6 months.

• Replace the 

fi

 lter every 3 years or 

replace any damaged 

fi

 lters. 

  Part no: CZ-SA13P

SUPER ALLERU-BUSTER

 

Washing Instructions

•  Do not use benzene, thinner or 

scouring powder.

•  Use only soaps or neutral household 

detergent (

pH7).

•  Do not use water hotter than 40°C.

•  Ionizer cleaning is recommended 

every 6 months.

IONIZER

 

Hints

• Clean the 

fi

 lter regularly for best 

performance and to reduce power 
consumption.

•  Please consult your nearest dealer 

for seasonal inspection.

 

For extended non-use

•  Activate heating for 2~3 hours to thoroughly dry the unit.
•  Turn off the power supply and unplug.
•  Remove the remote control batteries.

FRONT PANEL

FRONT PANEL

FRONT PANEL

AIR FILTER

AIR FILTER

AIR FILTER

SUPERSONIC AIR 

PURIFYING DEVICE

SUPERSONIC AIR 

SUPERSONIC AIR 

PURIFYING DEVICE

PURIFYING DEVICE

INDOOR UNIT

INDOOR UNIT

INDOOR UNIT

IONIZER

IONIZER

IONIZER

Switch off the power supply 

Switch off the power supply 

before cleaning

before cleaning

Switch off the power supply 

Switch off the power supply 

before cleaning

before cleaning

Содержание CS-E15EKEA

Страница 1: ...ze gebruiksinstructies grondig na en bewaar ze voor toekomstig gebruik 26 33 PORTUGUÊS Antes de ligar a unidade leia cuidadosamente este manual de utilização e guarde o para futura referência 34 41 EΛΛΗΝΙΚΆ Προτού θέσετε τη μονάδα σε λειτουργία διαβάστε προσεκτικά αυτές τις οδηγίες χρήσης και φυλάξτε τις για μελλοντική αναφορά 42 49 БЪЛГАРСКИ Преди да задействате климатика прочетете внимателно инс...

Страница 2: ...m infants and small children to prevent them from accidentally swallowing the batteries Do not install remove and reinstall the unit by yourself improper installation will cause leakage electric shock or fire Please consult an authorized dealer or specialist for the installation work This equipment must be earthed and installed with ELCB It may cause electrical shock or fire in case of malfunction...

Страница 3: ...rrect waste handling This dismantling and disposal of refrigerant oil and other parts must be done by a qualified installer in accordance with relevant local and national regulations Air conditioners must be treated at a specialized treatment facility for re use recycling and recovery and should not be disposed of in the municipal waste stream Please contact your installer dealer or local authorit...

Страница 4: ...e event of an error the unit will stop and the timer indicator will blink 1 Press for 5 seconds 2 Press until you hear beep sound then jot down the error code Notes The unit may be operable with 4 beeps on a limited basis depending on the error F 1 SET 3 Press for 5 seconds to quit checking 4 Turn the unit off and reveal the error code to your nearest dealer C Air intake Airflow direction louver I...

Страница 5: ...n all modes Press again to stop the operation Start the operation Troubleshooting FAN SPEED AIR SWING AUTO HEAT COOL DRY ION OFF ON TEMP MODE QUIET AIR SWING TIMER ON SET OFF CANCEL AC RC RESET SET CHECK CLOCK INVERTER 1 3 2 POWERFUL FAN SPEED ion M 2 2 2 ED 3 3 3 1 1 1 N PEED AIR S ON Hint A temperature setting 1 C higher in cooling operation or 2 C lower in heating operation than the desired tem...

Страница 6: ...G operation the air blows horizontally for a while then starts to blow downwards Keeps the room ventilated There are 5 options for vertical horizontal airflow direction Do not adjust the vertical and horizontal louvers by hand AIR SWING The room has a peculiar odour This may be a damp smell emitted by the wall carpet furniture or clothing Indoor fan stops occasionally during automatic fan speed se...

Страница 7: ... consumption close the curtains when operating air conditioner to prevent the sunlight and heat from coming in To provide a quiet environment This setting provides fresh air effect by producing negative ion Ion operation can be activated independently Press to turn off the operation Noisy during operation The unit may have been installed at an incline or the front panel is not closed properly Oper...

Страница 8: ... set If there is a power failure you can restore the previous setting once power is resumed by pressing the button If the timer is cancelled press to restore the previous setting Troubleshooting Timer indicator always on The timer setting repeats daily once set Remote control does not work The batteries are inserted incorrectly or need replacing The unit does not work The circuit breaker is trippe...

Страница 9: ...l household detergent pH7 Do not use water hotter than 40 C Ionizer cleaning is recommended every 6 months IONIZER Hints Clean the filter regularly for best performance and to reduce power consumption Please consult your nearest dealer for seasonal inspection For extended non use Activate heating for 2 3 hours to thoroughly dry the unit Turn off the power supply and unplug Remove the remote contro...

Страница 10: ... de batterijen van de afstandsbediening Controleer de inlaat en uitlaatopeningen op obstructies Het is normaal dat na 15 minuten gebruikstijd het temperatuurverschil tussen de inlaat en uitlaatopeningen als volgt is Bij koelen 8 C Bij verwarmen 14 C INSPECÇÃO SAZONAL APÓS UM PERÍODO DE INACTIVIDADE PROLONGADO Verifique as pilhas do controlo remoto Os orifícios de entrada e saída devem estar desobs...

Страница 11: ...standsbediening De stroomdraad wordt onnatuurlijk warm binnengedrongen De schakelaars of knoppen werken niet zoals het hoort Er lekt water uit de binneneenheid OMSTANDIGHEDEN WAARIN U HULP MOET INROEPEN Se si verifica una delle seguenti condizioni spegnere immediatamente l interruttore generale e chiamare il rivenditore autorizzato Durante il funzionamento si sentono rumori anomali L interruttore ...

Страница 12: ...Matsushita Electric Industrial Co Ltd Web Site http www panasonic co jp global F565136 Printed in Malaysia OPSC0512 01 ...

Отзывы: