45
12.1.4 Heating
Operation
12.1.4.1 Thermostat
control
Compressor is OFF when Intake Air Temperature - Internal Setting Temperate > +2.0°C.
Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature <
Compressor OFF point.
12.1.5 Automatic
Operation
This mode can be set using remote control and the operation is decided by remote control setting temperature,
remote control operation mode and indoor intake air temperature.
During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect the
indoor intake air temperature.
Every 10 minutes, the indoor temperature is judged.
For the 1st judgment
o
If indoor intake temperature - remote control setting temperature
≥
2°C, COOL mode is decided.
o
If
-2°C
≤
indoor intake temperature - remote control setting temperature < 2°C, DRY mode is decided.
o
If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.
For the 2nd judgment onwards
o
If indoor intake temperature - remote control setting temperature
≥
3°C, if previous operate in DRY mode,
then continue in DRY mode. otherwise COOL mode is decided.
o
If
-2°C
≤
indoor intake temperature - remote control setting temperature < 3°C, maintain with previous mode.
o
If indoor intake temperature - remote control setting temperature < -2°C, HEAT mode is decided.
12.1.6 Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
i. Manual Fan Speed
[Cooling, Dry]
Fan motor’s number of rotation is determined according to remote control setting.
Remote
Control
O O O O O
Tab (rpm)
Hi
Me+
Me
Me-
Lo
[Heating]
Fan motor’s number of rotation is determined according to remote control setting.
Remote
Control
O O O O O
Tab (rpm)
Shi
Me+
Me
Me-
Lo
ii. Auto Fan Speed
[Cooling, Dry]
According to room temperature and setting temperature, indoor fan speed is determined automatically.
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Содержание CS-E12QD3EAW
Страница 22: ...22 5 Dimensions 5 1 Indoor Unit AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 23: ...23 5 2 Outdoor Unit AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 24: ...24 6 Refrigeration Cycle Diagram AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 25: ...25 7 Block Diagram AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 26: ...26 8 Wiring Connection Diagram 8 1 Indoor Unit AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 28: ...28 9 Electronic Circuit Diagram 9 1 Indoor Unit AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 29: ...29 9 2 Outdoor Unit AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 39: ...39 11 1 6 1 WIRE STRIPPING AND CONNECTING REQUIREMENT AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 57: ...57 15 4 Error Codes Table AMP Air Conditioning www ampair co uk sales ampair co uk ...