CAUTION 

WARNING 

 

19. During installation, install the refrigerant piping properly before run the compressor. (Operation of compressor without fixing refrigeration piping 
      and valves at opened condition will caused suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc). 
20. During pump down operation, stop the compressor before remove the refrigeration piping. (Removal of compressor while compressor is 
      operating and valves are opened will cause suck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, 
      injury etc.) 
21. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant  
      contacts with fire. 

22. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire. 

23. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury. 

24. Must not use other parts except original parts described in catalog and manual. 

25. Using of refrigerant other than the specified type may cause product damage, burst and injury etc. 

 
 

 

1.   Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the  
      unit, it may cause fire. 

2.   Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage  
      the furniture. 

3.   Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare  
      may break and cause refrigerant gas leakage. 
4.   Do not touch outdoor unit air inlet and aluminium fin. It may cause injury. 

5.   Select an installation location which is easy for maintenance. 

6.   Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use 
      a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C). 
      Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 
7.   Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following 
      methods. 
      Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries, 
      permanent connection of this room air conditioner to the power supply is prohibited. 
      i. Power supply connection to the receptacle using a power plug. Use an approved 15/16A (3/4~1.75HP) or 16A (2.0HP) or 20A (2.5HP) or  
         25A (3.0HP) power plug with earth pin for the connection to the socket. 
      ii. Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A (3/4~2.0HP), 20A (2.5HP) or  
         25A (3.0HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap. 
8.   Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts. 
      Take care of the liquid refrigerant, it may cause frostbite. 

9.   Installation or servicing work: It may need two people to carry out the installation or servicing work. 

10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc. 

11. Do not sit or step on the unit, you may fall down accidentally. 

12. Do not touch the sharp aluminium fins or edges of metal parts. 
      If you are required to handle sharp parts during installation or servicing, please wear hand glove. 
      Sharp parts may cause injury. 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CS-E12NKEW

Страница 1: ...E12NKE 3 CU E15NKE CU E18NKE CU E21NKE PRECAUTION OF LOW TEMPERATURE In order to avoid frostbite be assured of no refrigerant leakage during the installation or repairing of refrigerant circuit This service information is designed for experienced repair technicians only and is not designed for use by the general public It does not contain warnings or cautions to advise non technical individuals of...

Страница 2: ... Timer Control 73 12 9 Auto Restart Control 73 12 10 Indication Panel 74 12 11 nanoe G Operation 74 12 12 Mild Dry Cooling Operation 76 12 13 AUTO COMFORT and ECO NAVI Operation 76 13 Operation Control For Multi Split Connection 85 13 1 Cooling operation 85 13 2 Soft Dry Operation 85 13 3 Heating Operation 85 13 4 Automatic Operation 86 13 5 Indoor Fan Motor Operation 86 13 6 Powerful Mode Operati...

Страница 3: ...ly recommended to install with Earth Leakage Circuit Breaker ELCB or Residual Current Device RCD Otherwise it may cause electrical shock and fire in case equipment breakdown or insulation breakdown 10 Do not use joint cable for indoor outdoor connection cable Use the specified indoor outdoor connection cable refer to installation instruction CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly...

Страница 4: ...in It may cause injury 5 Select an installation location which is easy for maintenance 6 Pb free solder has a higher melting point than standard solder typically the melting point is 50 F 70 F 30 C 40 C higher Please use a high temperature solder iron In case of the soldering iron with temperature control please set it to 700 20 F 370 10 C Pb free solder will tend to splash when heated too high ab...

Страница 5: ...5 46 Cooling Outdoor Noise H L Power Level dB 60 61 kW 0 75 2 80 4 00 0 85 3 40 5 00 BTU h 2560 9550 13600 2900 11600 17100 Capacity Kcal h 650 2410 3440 730 2920 4300 Running Current A 3 0 3 4 Input Power W 230 635 1 02k 240 735 1 30k W W 3 26 4 41 3 92 3 54 4 63 3 85 BTU hW 11 13 15 04 13 33 12 08 15 78 13 15 COP Kcal hW 2 83 3 80 3 37 3 04 3 97 3 31 Power Factor 92 94 dB A 38 25 20 40 27 20 Ind...

Страница 6: ...ft 3 min 10 9 385 11 3 400 Hi Heat m 3 min ft 3 min 11 4 400 11 7 415 Cool m 3 min ft 3 min 11 60 410 11 70 413 Indoor Airflow SHi Heat m 3 min ft 3 min 12 00 424 12 10 427 Cool m 3 min ft 3 min 33 9 1195 29 8 1050 Outdoor Airflow Hi Heat m 3 min ft 3 min 33 9 1195 29 8 1050 Control Device Check Valve Capillary Tube Check Valve Capillary Tube Refrigerant Oil cm 3 FV50S 320 FV50S 320 Refrigeration ...

Страница 7: ...ulb Wet Bulb Maximum 32 23 32 23 Cooling Minimum 16 11 16 11 Maximum 30 30 Indoor Operation Range Heating Minimum 16 16 Maximum 43 26 43 26 Cooling Minimum 5 4 5 4 Maximum 24 18 24 18 Outdoor Operation Range Heating Minimum 5 6 5 6 1 Cooling capacities are based on indoor temperature of 27 C Dry Bulb 80 6 F Dry Bulb 19 0 C Wet Bulb 66 2 F Wet Bulb and outdoor air temperature of 35 C DRY BULB 95 F ...

Страница 8: ... Cooling Outdoor Noise H L Power Level dB 63 64 kW 0 85 4 00 6 00 0 85 5 30 6 80 BTU h 2900 13600 20500 2900 18100 23200 Capacity Kcal h 730 3440 5160 730 4560 5850 Running Current A 4 3 6 6 Input Power W 245 930 1 71k 255 1 44k 1 94k W W 3 47 4 30 3 51 3 33 3 68 3 51 BTU hW 11 84 14 62 11 99 11 37 12 57 11 96 COP Kcal hW 2 98 3 70 3 02 2 86 3 17 3 02 Power Factor 94 95 dB A 42 33 20 43 35 29 Indo...

Страница 9: ...in ft 3 min 12 5 440 12 5 440 Hi Heat m 3 min ft 3 min 12 8 450 13 4 475 Cool m 3 min ft 3 min 13 10 463 13 30 470 Indoor Airflow SHi Heat m 3 min ft 3 min 13 30 470 13 60 480 Cool m 3 min ft 3 min 33 3 1175 33 3 1175 Outdoor Airflow Hi Heat m 3 min ft 3 min 33 3 1175 33 3 1175 Control Device Check Valve Capillary Tube Check Valve Capillary Tube Refrigerant Oil cm 3 FV50S 320 FV50S 400 Refrigerati...

Страница 10: ...lb Wet Bulb Maximum 32 23 32 23 Cooling Minimum 16 11 16 11 Maximum 30 30 Indoor Operation Range Heating Minimum 16 16 Maximum 43 26 43 26 Cooling Minimum 5 4 5 4 Maximum 24 18 24 18 Outdoor Operation Range Heating Minimum 5 6 5 6 1 Cooling capacities are based on indoor temperature of 27 C Dry Bulb 80 6 F Dry Bulb 19 0 C Wet Bulb 66 2 F Wet Bulb and outdoor air temperature of 35 C DRY BULB 95 F D...

Страница 11: ...ooling Outdoor Noise H L Power Level dB 60 61 kW 0 75 2 80 4 00 0 85 3 40 5 00 BTU h 2560 9550 13600 2900 11600 17100 Capacity Kcal h 650 2410 3440 730 2920 4300 Running Current A 3 0 3 4 Input Power W 230 635 1 02k 240 735 1 30k W W 3 26 4 41 3 92 3 54 4 63 3 85 BTU hW 11 13 15 04 13 33 12 08 15 78 13 15 COP Kcal hW 2 83 3 80 3 37 3 04 3 97 3 31 Power Factor 92 94 dB A 38 25 20 40 27 20 Indoor No...

Страница 12: ...ft 3 min 10 9 385 11 3 400 Hi Heat m 3 min ft 3 min 11 4 400 11 7 415 Cool m 3 min ft 3 min 11 60 410 11 70 413 Indoor Airflow SHi Heat m 3 min ft 3 min 12 00 424 12 10 427 Cool m 3 min ft 3 min 33 9 1195 29 8 1050 Outdoor Airflow Hi Heat m 3 min ft 3 min 33 9 1195 29 8 1050 Control Device Check Valve Capillary Tube Check Valve Capillary Tube Refrigerant Oil cm 3 FV50S 320 FV50S 320 Refrigeration ...

Страница 13: ...b Wet Bulb Maximum 32 23 32 23 Cooling Minimum 16 11 16 11 Maximum 30 30 Indoor Operation Range Heating Minimum 16 16 Maximum 43 26 43 26 Cooling Minimum 5 4 5 4 Maximum 24 18 24 18 Outdoor Operation Range Heating Minimum 15 16 15 16 1 Cooling capacities are based on indoor temperature of 27 C Dry Bulb 80 6 F Dry Bulb 19 0 C Wet Bulb 66 2 F Wet Bulb and outdoor air temperature of 35 C DRY BULB 95 ...

Страница 14: ...B 58 dB A 48 Cooling Outdoor Noise H L Power Level dB 63 kW 0 85 4 40 6 70 BTU h 2900 15000 22800 Capacity Kcal h 730 3780 5760 Running Current A 5 1 Input Power W 245 1 09k 1 93k W W 3 47 4 04 3 47 BTU hW 11 84 13 76 11 81 COP Kcal hW 2 98 3 47 2 98 Power Factor 93 dB A 42 33 20 Indoor Noise H L QLo Power Level dB 58 dB A 50 Heating Outdoor Noise H L Power Level dB 65 Low Temp Capacity kW I Power...

Страница 15: ...ft 3 min 11 00 388 Cool m 3 min ft 3 min 12 5 440 Hi Heat m 3 min ft 3 min 12 8 450 Cool m 3 min ft 3 min 13 10 463 Indoor Airflow SHi Heat m 3 min ft 3 min 13 30 470 Cool m 3 min ft 3 min 31 0 1095 Outdoor Airflow Hi Heat m 3 min ft 3 min 31 0 1095 Control Device Check Valve Capillary Tube Refrigerant Oil cm 3 FV50S 320 Refrigeration Cycle Refrigerant Type g oz R410A 970 34 2 Height I D O D mm in...

Страница 16: ...nimum 16 Maximum 43 26 Cooling Minimum 5 4 Maximum 24 18 Outdoor Operation Range Heating Minimum 15 16 1 Cooling capacities are based on indoor temperature of 27 C Dry Bulb 80 6 F Dry Bulb 19 0 C Wet Bulb 66 2 F Wet Bulb and outdoor air temperature of 35 C DRY BULB 95 F Dry Bulb 24 C Wet Bulb 75 2 F Wet Bulb 2 Heating capacities are based on indoor temperature of 20 C Dry Bulb 68 F Dry Bulb and ou...

Страница 17: ... Cooling Outdoor Noise H L Power Level dB 61 62 kW 0 98 5 80 8 00 0 98 7 20 8 50 BTU h 3340 19800 27300 3340 24600 29000 Capacity Kcal h 840 4990 6880 840 6190 7310 Running Current A 6 9 9 4 Input Power W 340 1 54k 2 60k 340 2 10k 2 75k W W 2 88 3 77 3 08 2 88 3 43 3 09 BTU hW 9 82 12 86 10 50 9 82 11 71 10 55 COP Kcal hW 2 47 3 24 2 65 2 47 2 95 2 66 Power Factor 97 97 dB A 44 37 34 45 37 34 Indo...

Страница 18: ... 567 15 45 546 Cool m 3 min ft 3 min 16 3 575 17 3 610 Hi Heat m 3 min ft 3 min 17 9 630 18 5 655 Cool m 3 min ft 3 min 18 1 639 19 1 675 Indoor Airflow SHi Heat m 3 min ft 3 min 18 5 653 19 4 685 Cool m 3 min ft 3 min 39 2 1385 41 7 1470 Outdoor Airflow Hi Heat m 3 min ft 3 min 37 9 1340 40 4 1425 Control Device Expansion Valve Expansion Valve Refrigerant Oil cm 3 FV50S 450 FV50S 450 Refrigeratio...

Страница 19: ...b Wet Bulb Dry Bulb Wet Bulb Maximum 32 23 32 23 Cooling Minimum 16 11 16 11 Maximum 30 30 Indoor Operation Range Heating Minimum 16 16 Maximum 43 26 43 26 Cooling Minimum 5 4 5 4 Maximum 24 18 24 18 Outdoor Operation Range Heating Minimum 5 6 5 6 1 Cooling capacities are based on indoor temperature of 27 C Dry Bulb 80 6 F Dry Bulb 19 0 C Wet Bulb 66 2 F Wet Bulb and outdoor air temperature of 35 ...

Страница 20: ...s air conditioning of up to two separate rooms for CU 2E15LBE CU 2E18LBE o A single outdoor unit enables air conditioning of up to three separate rooms for CU 3E18LBE o A single outdoor unit enables air conditioning of up to four separate rooms for CU 4E23LBE CU 4E27CBPG ...

Страница 21: ...21 Outdoor Unit CU 2E15LBE Outdoor Unit CU 2E18LBE ...

Страница 22: ...22 Outdoor Unit CU 3E18LBE ...

Страница 23: ...23 Outdoor Unit CU 4E23LBE ...

Страница 24: ...24 ...

Страница 25: ...25 Outdoor Unit CU 4E27CBPG ...

Страница 26: ...26 ...

Страница 27: ... single split connection only Easy to use remote control Quality Improvement o Random auto restart after power failure for safety restart operation o Gas leakage protection o Prevent compressor reverse cycle o Inner protector to protect compressor o Noise prevention during soft dry operation Operation Improvement o Quiet mode to reduce the indoor unit operating sound o Powerful mode to reach the d...

Страница 28: ...28 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...

Страница 29: ...29 5 Dimensions 5 1 Indoor Unit 5 1 1 CS E7NK CS E9NK CS E12NK CS E15NK CS XE7NK CS XE9NK CS XE12NK CS XE15NK ...

Страница 30: ...30 5 1 2 CS E18NK CS E21NK CS XE18NK CS XE21NK ...

Страница 31: ...31 5 2 Outdoor Unit 5 2 1 CU E7NKE CU E9NKE CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 5 2 2 CU E12NKE CU E15NKE ...

Страница 32: ...32 5 2 3 CU E18NKE CU E21NKE ...

Страница 33: ...33 6 Refrigeration Cycle Diagram 6 1 CU E7NKE CU E9NKE CU E12NKE CU E15NKE ...

Страница 34: ...34 6 2 CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...

Страница 35: ...35 6 3 CU E18NKE ...

Страница 36: ...36 6 4 CU E21NKE ...

Страница 37: ...37 7 Block Diagram 7 1 CU E7NKE CU E9NKE ...

Страница 38: ...38 7 2 CU E12NKE ...

Страница 39: ...39 7 3 CU E15NKE ...

Страница 40: ...40 7 4 CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...

Страница 41: ...41 7 5 CU E18NKE CU E21NKE ...

Страница 42: ...42 8 Wiring Connection Diagram 8 1 Indoor Unit ...

Страница 43: ...43 8 2 Outdoor Unit 8 2 1 CU E7NKE CU E9NKE ...

Страница 44: ...44 8 2 2 CU E12NKE ...

Страница 45: ...45 8 2 3 CU E15NKE ...

Страница 46: ...46 8 2 4 CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...

Страница 47: ...47 8 2 5 CU E18NKE CU E21NKE ...

Страница 48: ...48 9 Electronic Circuit Diagram 9 1 Indoor Unit ...

Страница 49: ...49 9 2 Outdoor Unit 9 2 1 CU E7NKE CU E9NKE ...

Страница 50: ...50 9 2 2 CU E12NKE ...

Страница 51: ...51 9 2 3 CU E15NKE ...

Страница 52: ...52 9 2 4 CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...

Страница 53: ...53 9 2 5 CU E18NKE CU E21NKE ...

Страница 54: ...54 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...

Страница 55: ...55 10 1 2 Indicator Printed Circuit Board 10 1 3 High Voltage Power Supply Printed Circuit Board 10 1 4 Comparator Printed Circuit Board ...

Страница 56: ...56 10 1 5 Human Activity Sensor Printed Circuit Board ...

Страница 57: ...57 10 2 Outdoor Unit 10 2 1 CU E7NKE CU E9NKE CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 ...

Страница 58: ...58 10 2 2 CU E12NKE CU E15NKE ...

Страница 59: ...59 10 2 3 CU E18NKE CU E21NKE ...

Страница 60: ...ructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do not place any obstacles which may cause a short circuit of the discharged air If piping length is over the piping length for additional gas additional refrigerant should be added as shown in the table Piping size Model Horse ...

Страница 61: ...s o Always mount the installation plate horizontally by aligning the marking off line with the thread and using a level gauge 2 Drill the piping plate hole with ø70 mm hole core drill o Line according to the left and right side of the installation plate The meeting point of the extended line is the center of the hole Another method is by putting measuring tape at position as shown in the diagram a...

Страница 62: ...62 11 2 3 1 For the right rear piping 11 2 3 2 For the right and right bottom piping 11 2 3 3 For the embedded piping This can be used for left rear piping and bottom piping also ...

Страница 63: ...3 Bind all the indoor and outdoor connection cable with tape and route the connection cable via the escapement 4 Remove the tapes and connect the connection cable between indoor unit and outdoor unit according to the diagram below Note o Secure the connection cable onto the control board with the holder o Ensure the colour of wires of outdoor unit and the terminal Nos are the same to the indoor s ...

Страница 64: ...pipe cutter and then remove the burrs 2 Remove the burrs by using reamer If burrs are not removed gas leakage may be caused Turn the piping end down to avoid the metal powder entering the pipe 3 Please make flare after inserting the flare nut onto the copper pipes ...

Страница 65: ...tighten the flare nut with fingers Further tighten the flare nut with torque wrench in specified torque as stated in the table Connecting the Piping to Outdoor Decide piping length and then cut by using pipe cutter Remove burrs from cut edge Make flare after inserting the flare nut located at valve onto the copper pipe Align center of piping to valves and then tighten with torque wrench to the spe...

Страница 66: ... OPEN using a hexagonal wrench 4 mm 8 Mount valve caps onto the 2 way valve and the 3 way valve o Be sure to check for gas leakage If gauge needle does not move from 0 cmHg 0 MPa to 76 cmHg 0 1 MPa in the step e above take the following measure If the leak stops when the piping connections are tightened further continue working from step e If the leak does not stop when the connections are retight...

Страница 67: ...vices Disconnecting means should have minimum 3 0 mm contact gap Earth wire shall be Yellow Green Y G in colour and longer than other AC wires for safety reason 11 3 5 Piping Insulation 1 Please carry out insulation at pipe connection portion as mentioned in Indoor Outdoor Unit Installation Diagram Please wrap the insulated piping end to prevent water from going inside the piping 2 If drain hose o...

Страница 68: ...ettings and the operation environment The final shifted value will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit 12 1 2 Cooling Operation 12 1 2 1 Thermostat control Compressor is OFF when Intake Air Temperature Internal Setting Temperature 1 5 C continue for 3 minutes Compressor is ON after waiting for 3 minutes if the...

Страница 69: ...t onwards o If indoor intake temperature remote control setting temperature 3 C if previous operate in DRY mode then continue in DRY mode otherwise COOL mode is decided o If 2 C indoor intake temperature remote control setting temperature 3 C maintain with previous mode o If indoor intake temperature remote control setting temperature 2 C HEAT mode is decided 12 2 Indoor Fan Motor Operation 12 2 1...

Страница 70: ...arts operation and it stops 30 seconds after compressor stops operation 12 4 Airflow Direction There are two types of airflow vertical airflow directed by horizontal vane and horizontal airflow directed by vertical vanes Control of airflow direction can be automatic angles of direction is determined by operation mode heat exchanger temperature and intake air temperature and manual angles of direct...

Страница 71: ...ection can be set using remote control the angles of the vane are as stated above and the positions of the vane are as Figure 2 below When the air conditioner is stopped using remote control the vane will shift to close position 12 4 2 Horizontal Airflow Automatic horizontal airflow direction can be set using remote control the vane swings left and right within the angles as stated below For heati...

Страница 72: ...off when on back quiet operation is not memorised Control contents o Fan speed is changed from normal setting to quiet setting of respective fan speed This is to reduce sound of Hi Me Lo for 3dB some models more than 3dB o Fan speed for quiet operation is reduced from setting fan speed 12 6 Quiet operation Heating Purpose o To provide quiet heating operation compare to normal operation Control con...

Страница 73: ...emote control the unit with timer set will start operate earlier than the setting time This is to provide a comfortable environment when reaching the set ON time 60 minutes before the set time indoor at fan speed of Lo and outdoor fan motor start operate for 30 seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting time From the ...

Страница 74: ... thermostat off etc nanoe G operation resume after indoor fan restarts o When indoor intake temperature 40 C nanoe G operation resume after indoor intake temperature 40 C continuously for 30 minutes Indoor fan control o During any operation mode combines with nanoe G operation fan speed follows respective operation mode However nanoe G system enabled when fan speed 500rpm to ensure proper negative...

Страница 75: ...n nanoe G check mode o To enable nanoe G check mode during nanoe G operation ON o If there is abnormal discharge nanoe G indicator blinks immediately Error detection control When nanoe G indicator blinks it indicates error listed below o nanoe G connector at main PCB open Judgment method During nanoe G operation nanoe G connector at main PCB is opened Troubleshooting method Connect the connector o...

Страница 76: ...n is pressed Mild Dry Cooling operation starts and Mild Dry Cooling indicators turns ON at remote control display Mild dry cooling operation is unavailable when the unit is operating Auto mode and Soft Dry model operation Mild dry cooling operation is cancelled when the unit turned OFF Mild Dry Cooling button is pressed again or when the operation mode changed from Cooling to other mode ECONAVI Po...

Страница 77: ... 3 70 seconds Repeat Step I to IV Indicator ON Indicator OFF 12 13 1 Human Activity Sensor Area of human availability activity level and absent is judged based on pulses by using 2 infrared sensors The internal setting temperature shift fan speed and horizontal airflow direction are adjusted in order to provide comfort environment while maintain the energy saving level AUTO COMFPRT ECO NAVI initia...

Страница 78: ...s o Non Living Area near windows wall etc 12 13 1 4 Human Position Analysis According to Area of Living frequency of activity and indoor unit intake temperature the system will analyze the human position away from the indoor unit 12 13 1 5 Target Area and Position Judgment The system will judge the indoor unit installation position according to human activity Non Living Area o Non Living Area at P...

Страница 79: ...irection louver steps at the targeted activity areas is judged Operation mode Activity level difference Louver stop time 1 level Higher Activity level 60 seconds Lower Activity level 30 seconds Cooling 2 levels Higher Activity level 60 seconds Lower Activity level 8 seconds When 3 activity areas have been detected according to Human Activity Level the timing of horizontal airflow louver steps at t...

Страница 80: ...s Infrared sensor Human Activity Sensor Sensor 1 Sensor 2 Left Center Right Vane position Fan speed 1 0 5 HI 1 1 Auto Swing HI 0 1 1 HI 0 0 Auto Swing LO The target area will maintain for 5 seconds before changeover to next detection If no activity detection the last action will maintain for 30 seconds before changeover to human absence status ...

Страница 81: ... reset When abnormality counter reached 4 times H59 occurred No TIMER indicator blinking When error code happened the unit is able to operate without AUTO COMF ECO NAVI 12 13 2 3 Infrared Sensor Check Mode To enable Infrared sensor abnormality check mode During ECO NAVI is ON when CHECK signal received if either sensors has abnormality the 4 times abnormality counter is ignored ECO NAVI Indicator ...

Страница 82: ...ight judgment is as following 12 13 3 1 Sunlight Intensity Reset The sunlight intensity will to reset to zero no sunlight condition when o Each time ECONAVI is activated o Setting temperature is changed o Operation mode is changed 12 13 3 2 Judge Sunlight Intensity Based on sunlight sensor output voltage the sunlight intensity value will be computed and logged to sunlight intensity database The su...

Страница 83: ...zed but it operation be ignored o During check mode if the sunlight sensor check code is retransmitted the 5 minutes counter will be reset o During check mode if sunlight sensor detected the sunlight intensity value above minimum level the ECONAVI indicator turns ON Else if sunlight sensor detected sunlight intensity value below minimum level the ECONAVI indicator is OFF To disable sunlight sensor...

Страница 84: ...tion error counter will increase by 1 time If the ECONAVI is OFF the 24 hours timer will be reset but the sunlight sensor disconnection error counter will not be reset Error Code judgment o When sunlight sensor disconnection error counter reached 15 times H70 occurred o No TIMER indicator or ECONAVI indicator blink When error code happened the unit is able to operate without sunlight sensor ...

Страница 85: ...etting temperature Capability supply OFF point 13 3 Heating Operation 13 3 1 Thermostat control Capability supply to indoor unit is OFF Expansion valve closed when Intake Air Temperature Internal setting temperature 1 0 C During this condition the indoor fan is stopped if compressor is ON Capability resume supply to indoor unit after waiting for 3 minutes if the Intake Air Temperature Internal set...

Страница 86: ... heating than remote control setting temperature the powerful operation continue until user cancel the Powerful operation by pressing powerful button again 13 7 Auto restart control When the power supply is cut off during the operation of air conditioner the compressor will re operate between three to four minutes 10 patterns to be selected randomly after power resume During multi split connection...

Страница 87: ...5 06 8 25 15 06 11 81 14 75 12 27 14 75 Cooling Soft Dry B 3 33 15 06 4 20 15 06 6 20 15 06 6 42 15 06 7 74 15 06 8 91 14 75 11 10 14 75 Heating 4 46 15 06 5 57 15 06 7 30 15 06 8 10 15 06 8 40 15 06 10 07 14 75 11 58 14 75 4 The first 30 minutes of cooling operation A will be applied 14 1 3 IPM Power transistor Prevention Control Overheating Prevention Control 1 When the IPM temperature rises to ...

Страница 88: ...door suction temperature indoor piping temperature is below 4 C o During Heating operations Indoor piping temperature indoor suction is under 5 C Control contents o Compressor stops and restart after 3 minutes o If the conditions above happen 2 times within 20 minutes the unit will Stop operation Timer LED blinks and F91 indicated 14 1 6 Low Frequency Protection Control 1 When the compressor opera...

Страница 89: ...door heat exchanger is higher than 5 C At the same time indoor fan speed will be higher than during its normal operation If indoor heat exchanger temperature is higher than 5 C for 5 minutes the fan speed will return to its normal operation 14 2 4 Freeze Prevention Control 2 Control start conditions o During Cooling operation and soft dry operation During thermo OFF condition indoor intake tempera...

Страница 90: ...or Air Temperature Control The Max current value is regulated when the outdoor air temperature rise above 16 C E7 15NK and 14 C E18 21NK in order to avoid compressor overloading 14 3 3 Overload Protection Control The compressor operating frequency is regulated in accordance to indoor heat exchanger temperature as shown below If the heat exchanger temperature exceeds 60 C compressor will stop 14 3 ...

Страница 91: ...ion 3 REMOTE CONTROL NUMBER SWITCH MODE The Remote Control Number Switch Mode will be activated if the Auto OFF ON button is pressed continuously for more than 11 seconds 3 beep sounds will occur at 11th seconds to identify the Remote Control Number Switch Mode is in standby condition and press AC RESET button and then press any button at remote control to transmit and store the desired transmissi...

Страница 92: ...emote Control Receiving Sound OFF ON Mode is restarted 15 2 Remote Control Button 15 2 1 SET Button To check remote control transmission code and store the transmission code to EEPROM o Press Set button continuously for 10 seconds by using pointer o Press Timer Set button until a beep sound is heard as confirmation of transmission code changed 15 2 2 RESET RC To clear and restore the remote contro...

Страница 93: ...nd a fan The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions the standard values for them are shown in the table on the right Normal Pressure and Outlet Air Temperature Standard Gas Pressure Mpa kg cm 2 G Outlet air Temperature C Cooling Mode 0 9 1 2 9 12 12 16 Heating Mode 2 3 2 9 23 29 36 45 Condition Indoor fan speed High Outdoor temperature 3...

Страница 94: ...ation Low Pressure High Pressure Electric current during operation Insufficient refrigerant gas leakage Ô Ô Ô Ô Ô Ô Clogged capillary tube or Strainer Ô Ô Ô Ò Ò Ò Short circuit in the indoor unit Ô Ô Ô Ò Ò Ò Heat radiation deficiency of the outdoor unit Ò Ò Ò Ô Ô Ô Inefficient compression Ò Ô Ô Ò Ô Ô Carry out the measurement of pressure electric current and temperature fifteen minutes after an op...

Страница 95: ...To Display Memorized Error Code Protective Operation 1 Turn power on 2 Press the CHECK button on the remote controller continuously for 5 seconds 3 will be displayed on the remote controller display Note Display only for No transmitting signal no receiving sound and no Power LED blinking 4 Press the TIMER or button on the remote controller The code H00 no abnormality will be displayed and signal w...

Страница 96: ...96 16 3 Error Codes Table ...

Страница 97: ...97 ...

Страница 98: ...transmission is checked whether it is normal Malfunction Caused Faulty indoor unit PCB Faulty outdoor unit PCB Indoor unit outdoor unit signal transmission error due to wrong wiring Indoor unit outdoor unit signal transmission error due to breaking of wire in the connection wires between the indoor and outdoor units Indoor unit outdoor unit signal transmission error due to disturbed power supply w...

Страница 99: ...are interconnected Malfunction Caused Wrong models interconnected Wrong indoor unit or outdoor unit PCBs mounted Indoor unit or outdoor unit PCBs defective Indoor outdoor unit signal transmission error due to wrong wiring Indoor outdoor unit signal transmission error due to breaking of wire 3 in the connection wires between the indoor and outdoor units Troubleshooting ...

Страница 100: ...ction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the indoor intake air temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 101: ...n Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor compressor temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 102: ...tions A current transformer CT is detected by checking the compressor running frequency rated frequency and CT detected input current less than 0 65A for continuously 20 seconds Malfunction Caused CT defective Outdoor PCB defective Compressor defective low compression Troubleshooting ...

Страница 103: ...determine abnormal fan motor feedback of rotation 2550rpm or 50rpm Malfunction Caused Operation stops due to short circuit inside the fan motor winding Operation stops due to breaking of wire inside the fan motor Operation stops due to breaking of fan motor lead wires Operation stops due to Hall IC malfunction Operation error due to faulty indoor unit PCB Troubleshooting ...

Страница 104: ... Decision Conditions During startup and operation of cooling and heating the temperatures detected by the indoor heat exchanger temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 105: ...ction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor air temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 106: ...ction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor pipe temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 107: ...ction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor discharge pipe temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 108: ...unction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor heat exchanger temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 109: ...Malfunction Decision Conditions The supply power is detected for its requirement by the indoor outdoor transmission Malfunction Caused Wrong models interconnected Wrong indoor unit and outdoor unit PCBs used Indoor unit or outdoor unit PCB defective Troubleshooting ...

Страница 110: ...nction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor heat sink temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 111: ... Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor gas pipe temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 112: ...nction Decision Conditions During startup and operation of cooling and heating the temperatures detected by the outdoor liquid pipe temperature sensor are used to determine sensor errors Malfunction Caused Faulty connector connection Faulty sensor Faulty PCB Troubleshooting ...

Страница 113: ...eration is used to determine abnormal fan motor Malfunction Caused Operation stops due to short circuit inside the fan motor winding Operation stops due to breaking of wire inside the fan motor Operation stops due to breaking of fan motor lead wires Operation stops due to Hall IC malfunction Operation error due to faulty outdoor unit PCB Troubleshooting ...

Страница 114: ...ature detected by the indoor pipe temperature sensor is above 60 C Malfunction Caused Air short circuit at indoor unit Clogged indoor unit air filter Dust accumulation on the indoor unit heat exchanger 2 3 way valve closed Faulty indoor unit fan motor Excessive refrigerant Clogged expansion valve or strainer Faulty indoor pipe temperature sensor Faulty indoor unit PCB Troubleshooting ...

Страница 115: ...l takes place when indoor pipe temperature is lower than 2 C Malfunction Caused Air short circuit at indoor unit Clogged indoor unit air filter Dust accumulation on the indoor unit heat exchanger 2 3 way valve closed Faulty indoor unit fan motor Refrigerant shortage refrigerant leakage Clogged expansion valve or strainer Faulty indoor pipe temperature sensor Faulty indoor unit PCB Troubleshooting ...

Страница 116: ...Conditions When heating operation when indoor pipe temperature is below 10 C When cooling operation when indoor pipe temperature is above 45 C Malfunction Caused Connector in poor contact Faulty sensor Faulty outdoor unit PCB 4 way valve defective Troubleshooting ...

Страница 117: ...erature and indoor pipe temperature is above 10 C or indoor pipe temperature is below 1 0 C Remark When the indoor standby unit is freezing the outdoor unit transfers F17 error code to the corresponding indoor unit and H39 to other indoor unit s Malfunction Caused Wrong wiring connection Faulty sensor Faulty expansion valve Troubleshooting ...

Страница 118: ...operation of cooling and heating when Power Factor Correction PFC protection circuitry at the outdoor unit main PCB senses abnormal high DC voltage level Malfunction Caused DC voltage peak due to power supply surge DC voltage peak due to compressor windings not uniform Faulty outdoor PCB Troubleshooting ...

Страница 119: ...king the CT detected input current value and the compressor running frequency During startup and operating of cooling and heating input current 8 78 256 A Hz x compressor running frequency 0 25 Gas shortage detection 2 A gas shortage is detected by checking the difference between indoor pipe temperature and indoor intake air temperature during cooling and heating Malfunction Caused Faulty indoor i...

Страница 120: ...tion Decision Conditions A compressor rotation failure is detected by checking the compressor running condition through the position detection circuit Malfunction Caused Compressor terminal disconnect Faulty Outdoor PCB Faulty compressor Troubleshooting ...

Страница 121: ...ture data 61 C is detected by the outdoor pipe temperature sensor Malfunction Caused Air short circuit at indoor unit Dust accumulation on the indoor unit heat exchanger 2 3 way valve closed Faulty outdoor unit fan motor Excessive refrigerant Clogged expansion valve or strainer Faulty outdoor pipe temperature sensor Faulty outdoor unit PCB Troubleshooting ...

Страница 122: ...ted o Heat Sink Overheating During operation of cooling and heating when heat sink temperature data 90 C is detected by the heat sink temperature sensor Malfunction Caused IPM overheats due to short circuit of hot discharge air flow IPM overheats due to defective of outdoor fan motor IPM overheats due to defective of internal circuitry of IPM IPM overheats due to defective IPM temperature sensor M...

Страница 123: ...ling and heating when compressor tank temperature data 112 C is detected by the compressor tank temperature sensor Malfunction Caused Faulty compressor tank temperature sensor 2 3 way valve closed Refrigerant shortage refrigerant leakage Faulty outdoor unit PCB Faulty compressor Troubleshooting ...

Страница 124: ...ion of cooling and heating when an input over current X value in Total Running Current Control is detected by checking the input current value being detected by current transformer CT with the compressor running Malfunction Caused Excessive refrigerant Faulty outdoor unit PCB Troubleshooting ...

Страница 125: ...ubleshooting Checking the power transistor Never touch any live parts for at least 10 minutes after turning off the circuit breaker If unavoidable necessary to touch a live part make sure the power transistor s supply voltage is below 50V using the tester For the UVW make measurement at the Faston terminal on the board of the relay connector Tester s negative terminal Power transistor UVW Power tr...

Страница 126: ...harged sufficiently before proceeding with repair work Failure to heed this caution may result in electric shocks 17 1 CS E7NK CS E9NK CS E12NK CS E15NK CS XE7NK CS XE9NK CS XE12NK CS XE15NK 17 1 1 Indoor Electronic Controllers Cross Flow Fan and Indoor Fan Motor Removal Procedures 17 1 1 1 To remove front grille 17 1 1 2 To remove power electronic controller ...

Страница 127: ...127 17 1 1 3 To remove discharge grille ...

Страница 128: ...128 17 1 1 4 To remove control board 17 1 1 5 To remove cross flow fan and indoor fan motor ...

Страница 129: ...129 ...

Страница 130: ...0 17 2 CS E18NK CS E21NK CS XE18NK CS XE21NK 17 2 1 Indoor Electronic Controllers Cross Flow Fan and Indoor Fan Motor Removal Procedures 17 2 1 1 To remove front grille 17 2 1 2 To remove horizontal vane ...

Страница 131: ...131 17 2 1 3 To remove power electronic controller ...

Страница 132: ...132 17 2 1 4 To remove discharge grille 17 2 1 5 To remove control board 1 17 2 1 6 To remove cross flow fan and indoor fan motor ...

Страница 133: ...133 ...

Страница 134: ...en handling electronic controller be careful of electrostatic discharge 1 Remove the 3 screws of the Top Panel Fig 1 2 Remove the 6 screws of the Front Panel Fig 2 3 Remove the screw of the Terminal Board Cover 4 Remove the Top Cover of the Control Board by 4 hooks Fig 3 5 Remove the Control Board as follows Fig 4 Fig 5 Fig 6 ...

Страница 135: ...ul of electrostatic discharge 1 Remove the 5 screws of the Top Panel Fig 1 2 Remove the 8 screws of the Front Panel Fig 2 3 Remove the screw of the Terminal Board Cover 4 Remove the Top Cover of the Control Board by 4 hooks Fig 3 5 Remove the Control Board as follows Fig 4 Fig 5 Fig 6 ...

Страница 136: ...2 Remove the 10 screws of the Front Panel Fig 2 3 Remove the Top Cover of the Electronic Controller Fig 3 4 Remove the Control Board Fig 4 5 Remove the 8 screws of the Electronic Controller Fig 5 Caution When handling electronic controller be careful of electrostatic discharge ...

Страница 137: ...Outdoor Air Temperature C Outlet Air Tempeature C 230 1 700 1 900 2 100 2 300 2 500 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 1 100 1 300 1 500 1 700 1 900 2 100 2 300 2 500 2 700 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 790 0 890 0 990 1 090 1 190 5 7 9 11 13 15 17 19 21 23 25 27 29 ...

Страница 138: ...8 9 10 11 12 13 14 15 Piping Length m Cooling Capacity kW 2 180 2 190 2 200 2 210 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 1 080 1 090 1 100 1 110 1 120 1 130 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 18 400 18 600 18 800 19 000 19 200 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 139: ... Outdoor Air Temperature C Outlet Air Tempeature C 230 1 800 2 000 2 200 2 400 2 600 2 800 3 000 3 200 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 2 500 2 700 2 900 3 100 3 300 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 2 000 2 200 2 400 2 600 2 800 3 000 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas Side Piping Pressure...

Страница 140: ...9 10 11 12 13 14 15 Piping Length m Heating Capacity kW 2 920 2 940 2 960 2 980 3 000 3 020 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 2 600 2 620 2 640 2 660 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 31 900 32 000 32 100 32 200 32 300 32 400 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 141: ...utlet Air Tempeature C 230 2 100 2 300 2 500 2 700 2 900 3 100 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 1 300 1 500 1 700 1 900 2 100 2 300 2 500 2 700 2 900 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 790 0 890 0 990 1 090 1 190 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 ...

Страница 142: ...8 9 10 11 12 13 14 15 Piping Length m Cooling Capacity kW 2 480 2 490 2 500 2 510 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 1 070 1 080 1 090 1 100 1 110 1 120 1 130 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 17 100 17 300 17 500 17 700 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 143: ... 4 5 6 7 8 9 10 Outdoor Air Temperature C Outlet Air Tempeature C 230 2 200 2 700 3 200 3 700 4 200 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 2 900 3 100 3 300 3 500 3 700 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 1 800 2 000 2 200 2 400 2 600 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas Side Piping Pressure MPa ...

Страница 144: ...9 10 11 12 13 14 15 Piping Length m Heating Capacity kW 3 320 3 340 3 360 3 380 3 400 3 420 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 2 340 2 360 2 380 2 400 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 34 400 34 500 34 600 34 700 34 800 34 900 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 145: ...C Outlet Air Tempeature C 230 3 000 3 200 3 400 3 600 3 800 4 000 4 200 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 2 000 2 500 3 000 3 500 4 000 4 500 5 000 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 680 0 780 0 880 0 980 1 080 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Out...

Страница 146: ...8 9 10 11 12 13 14 15 Piping Length m Cooling Capacity kW 3 800 3 900 4 000 4 100 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 0 920 0 930 0 940 0 950 0 960 0 970 0 980 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 15 200 15 400 15 600 15 800 16 000 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 147: ...10 Outdoor Air Temperature C Outlet Air Tempeature C 230 2 600 3 100 3 600 4 100 4 600 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 3 700 3 900 4 100 4 300 4 500 4 700 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 2 300 2 400 2 500 2 600 2 700 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas Side Piping Pressure MPa ...

Страница 148: ...1 12 13 14 15 Piping Length m Heating Capacity kW 4 300 4 320 4 340 4 360 4 380 4 400 4 420 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 2 440 2 460 2 480 2 500 2 520 2 540 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 34 200 34 300 34 400 34 500 34 600 34 700 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 149: ...r Air Temperature C Outlet Air Tempeature C 230 3 600 4 100 4 600 5 100 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 2 900 3 900 4 900 5 900 6 900 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 640 0 740 0 840 0 940 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperatu...

Страница 150: ...10 11 12 13 14 15 Piping Length m Cooling Capacity kW 5 400 5 500 5 600 5 700 5 800 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 0 870 0 880 0 890 0 900 0 910 0 920 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 14 000 14 100 14 200 14 300 14 400 14 500 14 600 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 151: ...ature C Outlet Air Tempeature C 230 3 400 3 900 4 400 4 900 5 400 5 900 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 5 600 5 800 6 000 6 200 6 400 6 600 6 800 7 000 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 2 300 2 400 2 500 2 600 2 700 2 800 2 900 3 000 3 100 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas Side Piping Pre...

Страница 152: ...6 7 8 9 10 11 12 13 14 15 Piping Length m Heating Capacity kW 6 400 6 500 6 600 6 700 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 2 870 2 890 2 910 2 930 2 950 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 38 200 38 300 38 400 38 500 38 600 38 700 38 800 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 153: ...Air Temperature C Outlet Air Tempeature C 230 1 700 1 900 2 100 2 300 2 500 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 1 100 1 600 2 100 2 600 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 790 0 890 0 990 1 090 1 190 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Tempe...

Страница 154: ...8 9 10 11 12 13 14 15 Piping Length m Cooling Capacity kW 2 180 2 190 2 200 2 210 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 1 080 1 090 1 100 1 110 1 120 1 130 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 18 400 18 600 18 800 19 000 19 200 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 155: ... Outdoor Air Temperature C Outlet Air Tempeature C 230 1 800 2 000 2 200 2 400 2 600 2 800 3 000 3 200 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 2 500 2 700 2 900 3 100 3 300 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 2 000 2 200 2 400 2 600 2 800 3 000 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas Side Piping Pressure...

Страница 156: ...3 14 15 Piping Length m Heating Capacity kW 2 920 2 940 2 960 2 980 3 000 3 020 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 2 600 2 610 2 620 2 630 2 640 2 650 2 660 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 31 900 32 000 32 100 32 200 32 300 32 400 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 157: ...Outlet Air Tempeature C 230 2 100 2 300 2 500 2 700 2 900 3 100 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 1 300 1 500 1 700 1 900 2 100 2 300 2 500 2 700 2 900 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 790 0 890 0 990 1 090 1 190 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43...

Страница 158: ...12 13 14 15 Piping Length m Cooling Capacity kW 2 480 2 490 2 500 2 510 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 1 070 1 080 1 090 1 100 1 110 1 120 1 130 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 17 100 17 200 17 300 17 400 17 500 17 600 17 700 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 159: ... 10 Outdoor Air Temperature C Outlet Air Tempeature C 230 2 200 2 400 2 600 2 800 3 000 3 200 3 400 3 600 3 800 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 2 900 3 100 3 300 3 500 3 700 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 1 800 2 000 2 200 2 400 2 600 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas Side Piping Press...

Страница 160: ...3 14 15 Piping Length m Heating Capacity kW 3 320 3 340 3 360 3 380 3 400 3 420 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 2 340 2 350 2 360 2 370 2 380 2 390 2 400 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 34 400 34 500 34 600 34 700 34 800 34 900 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 161: ... C Outlet Air Tempeature C 230 3 000 3 200 3 400 3 600 3 800 4 000 4 200 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 2 100 2 600 3 100 3 600 4 100 4 600 5 100 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 680 0 780 0 880 0 980 1 080 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Ou...

Страница 162: ...11 12 13 14 15 Piping Length m Cooling Capacity kW 4 080 4 090 4 100 4 110 4 120 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 0 920 0 930 0 940 0 950 0 960 0 970 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 14 900 15 000 15 100 15 200 15 300 15 400 15 500 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 163: ...8 9 10 Outdoor Air Temperature C Outlet Air Tempeature C 230 2 800 3 300 3 800 4 300 4 800 5 300 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 4 300 4 500 4 700 4 900 5 100 5 300 5 500 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 1 900 2 100 2 300 2 500 2 700 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas Side Piping Pressure...

Страница 164: ...2 13 14 15 Piping Length m Heating Capacity kW 4 980 5 000 5 020 5 040 5 060 5 080 5 100 5 120 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Current A 2 420 2 440 2 460 2 480 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Gas Side Piping Pressure MPa 35 100 35 200 35 300 35 400 35 500 35 600 3 4 5 6 7 8 9 10 11 12 13 14 15 Piping Length m Outlet Air Temperature C 230 ...

Страница 165: ... 35 37 39 41 43 Outdoor Air Temperature C Outlet Air Tempeature C 230 4 200 4 700 5 200 5 700 6 200 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 3 100 4 100 5 100 6 100 7 100 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 860 0 880 0 900 0 920 0 940 0 960 0 980 1 000 5 7 9 11 13 15 17 19 21 23...

Страница 166: ...0 11 12 13 14 15 16 17 18 19 20 Piping Length m Cooling Capacity kW 6 580 6 590 6 600 6 610 6 620 6 630 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Current A 0 900 0 910 0 920 0 930 0 940 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Gas Side Piping Pressure MPa 15 200 15 300 15 400 15 500 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Outlet Air...

Страница 167: ...2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Outlet Air Tempeature C 230 4 100 4 600 5 100 5 600 6 100 6 600 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 5 700 6 200 6 700 7 200 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 2 200 2 300 2 400 2 500 2 600 2 700 2 800 2 900 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas ...

Страница 168: ... 11 12 13 14 15 16 17 18 19 20 Piping Length m Heating Capacity kW 6 870 6 880 6 890 6 900 6 910 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Current A 2 770 2 775 2 780 2 785 2 790 2 795 2 800 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Gas Side Piping Pressure MPa 36 600 36 700 36 800 36 900 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Outle...

Страница 169: ... 41 43 Outdoor Air Temperature C Outlet Air Tempeature C 230 5 300 5 800 6 300 6 800 7 300 7 800 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Cooling Capacity kW 4 700 5 700 6 700 7 700 8 700 9 700 10 700 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 Outdoor Air Temperature C Current A 0 820 0 840 0 860 0 880 0 900 0 920 0 940 0 960 5 7 9 11 13 15 1...

Страница 170: ...9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Cooling Capacity kW 9 870 9 890 9 910 9 930 9 950 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Current A 0 850 0 860 0 870 0 880 0 890 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Gas Side Piping Pressure MPa 14 800 14 900 15 000 15 100 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Outlet Air Te...

Страница 171: ... 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Outlet Air Tempeature C 230 5 100 5 600 6 100 6 600 7 100 7 600 8 100 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Heating Capacity kW 7 700 8 200 8 700 9 200 9 700 10 200 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Current A 2 400 2 600 2 800 3 000 3 200 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 Outdoor Air Temperature C Gas ...

Страница 172: ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Heating Capacity kW 9 360 9 380 9 400 9 420 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Current A 3 010 3 020 3 030 3 040 3 050 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Gas Side Piping Pressure MPa 37 700 37 800 37 900 38 000 38 100 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Piping Length m Outlet ...

Страница 173: ...5 40 46 Indoor wet bulb temp TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17 0 C 3 47 2 63 0 79 3 24 2 52 0 85 3 02 2 43 0 91 2 74 2 30 0 98 19 0 C 3 50 0 86 19 5 C 3 81 2 76 0 80 3 56 2 65 0 86 3 31 2 55 0 92 3 01 2 43 1 00 22 0 C 4 15 2 86 0 82 3 88 2 75 0 88 3 61 2 65 0 94 3 28 2 53 1 01 CU E12NKE 3 230V Outdoor Temp C 30 35 40 46 Indoor wet bulb temp TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17 0 C 3...

Страница 174: ...0 5 55 3 93 1 50 5 16 3 79 1 61 4 69 3 61 1 73 CU E21NKE 230V Outdoor Temp C 30 35 40 46 Indoor wet bulb temp TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17 0 C 6 25 4 74 2 02 5 84 4 54 2 18 5 43 4 37 2 33 4 94 4 15 2 51 19 0 C 6 30 2 21 19 5 C 6 86 4 96 2 06 6 41 4 77 2 22 5 97 4 59 2 37 5 42 4 37 2 56 22 0 C 7 48 5 14 2 10 6 99 4 95 2 26 6 50 4 77 2 42 5 91 4 55 2 61 TC Total Cooling Capacity kW SHC...

Страница 175: ... Indoor Unit 19 1 1 CS E7NKEW CS E9NKEW CS E12NKEW CS E15NKEW CS XE7NKEW CS XE9NKEW CS XE12NKEW CS XE15NKEW Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts ...

Страница 176: ...ECO SENSOR 1 CWA746206 20 ELECTRONIC CONTROLLER COMPARATOR 1 CWA746653 21 LEAD WIRE PCB ECO 1 CWA67C9785 22 CONTROL BOARD CASING FOR PCB ECO 1 CWD933407 23 CONTROL BOARD TOP COVER 1 CWH131467 24 INDICATOR HOLDER 1 CWD933406 25 CONTROL BOARD FRONT COVER CO 1 CWH13C1247 26 DISCHARGE GRILLE COMPLETE 1 CWE20C3235 27 BACK COVER CHASSIS 1 CWD933233 28 FULCRUM 1 CWH621131 29 VERTICAL VANE 8 CWE241374 30 ...

Страница 177: ...177 52 SHOCK ABSORBER R 1 CWG713387 53 C C CASE 1 CWG567354 NOTE All parts are supplied from PAPAMY Malaysia Vendor Code 00029488 O marked parts are recommended to be kept in stock ...

Страница 178: ... ECO SENSOR 1 CWA746206 20 ELECTRONIC CONTROLLER COMPARATOR 1 CWA746653 21 LEAD WIRE PCB ECO 1 CWA67C9785 22 CONTROL BOARD CASING FOR PCB ECO 1 CWD933407 23 CONTROL BOARD TOP COVER 1 CWH131467 24 INDICATOR HOLDER 1 CWD933406 25 CONTROL BOARD FRONT COVER CO 1 CWH13C1247 26 DISCHARGE GRILLE COMPLETE 1 CWE20C3234 27 BACK COVER CHASSIS 1 CWD933233A 28 FULCRUM 1 CWH621131 29 VERTICAL VANE 8 CWE241374 3...

Страница 179: ...179 52 SHOCK ABSORBER R 1 CWG713387 53 C C CASE 1 CWG567354 NOTE All parts are supplied from PAPAMY Malaysia Vendor Code 00029488 O marked parts are recommended to be kept in stock ...

Страница 180: ...80 19 1 2 CS E18NKEW CS E21NKEW CS XE18NKEW CS XE21NKEW Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts ...

Страница 181: ...1 CWA746653 21 LEAD WIRE PCB ECO 1 CWA67C9934 22 CONTROL BOARD CASING FOR PCB ECO 1 CWD933407A 23 CONTROL BOARD TOP COVER 1 CWH131467 24 INDICATOR HOLDER 1 CWD933406 25 CONTROL BOARD FRONT COVER CO 1 CWH13C1247 26 DISCHARGE GRILLE COMPLETE 1 CWE20C3242 CWE20C3244 27 BACK COVER CHASSIS 1 CWD933031 CWD933031A 28 FULCRUM 2 CWH621138 29 VERTICAL VANE 11 CWE241374 30 CONNECTING BAR RIGHT 1 CWE261257 31...

Страница 182: ...182 52 SHOCK ABSORBER R 1 CWG713403 53 C C CASE 1 CWG567454 NOTE All parts are supplied from PAPAMY Malaysia Vendor Code 00029488 O marked parts are recommended to be kept in stock ...

Страница 183: ...oor Unit 19 2 1 CU E7NKE CU E9NKE CU E7NKE 3 CU E9NKE 3 CU E12NKE 3 Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts ...

Страница 184: ... COVER 1 CWH7080300J 22 SOUND PROOF BOARD 1 CWH151172 23A SOUND PROOF MATERIAL 1 CWG302443 CWG302293 24 SENSOR CO COMP TEMP 1 CWA50C2205 o 25 CONTROL BOARD COVER TOP 1 CWH131264 26 ELECTRONIC CONTROLLER MAIN 1 CWA73C6653R CWA73C6655R o 27 TERMINAL BOARD ASSY 1 CWA28K1110J o 28 CABINET SIDE PLATE CO RIGHT 1 CWE04C1116 29 SENSOR CO AIR TEMP AND PIPE TEMP 1 CWA50C2764 o 30 CABINET SIDE PLATE LEFT 1 C...

Страница 185: ...F BOARD 1 CWH151172 23A SOUND PROOF MATERIAL 1 CWG302316 23B SOUND PROOF MATERIAL 1 CWG302317 23C SOUND PROOF MATERIAL 1 CWG302315 24 SENSOR CO COMP TEMP 1 CWA50C2205 o 25 CONTROL BOARD COVER TOP 1 CWH131264 26 ELECTRONIC CONTROLLER MAIN 1 CWA73C6654R CWA73C6656R CWA73C6658R o 27 TERMINAL BOARD ASSY 1 CWA28K1110J o 28 CABINET SIDE PLATE CO RIGHT 1 CWE04C1116 29 SENSOR CO AIR TEMP AND PIPE TEMP 1 C...

Страница 186: ...186 19 2 2 CU E12NKE CU E15NKE Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts ...

Страница 187: ...SOUND PROOF BOARD 1 CWH151274 23A SOUND PROOF MATERIAL 1 CWG302317 23B SOUND PROOF MATERIAL 1 CWG302726 23C SOUND PROOF MATERIAL 1 CWG302701 24 SENSOR CO COMP TEMP 1 CWA50C2830 o 25 CONTROL BOARD COVER TOP 1 CWH131473 26 ELECTRONIC CONTROLLER MAIN 1 CWA73C6657R CWA73C6659R o 27 TERMINAL BOARD ASSY 1 CWA28K1110J o 28 CABINET SIDE PLATE CO 1 CWE04C1296 29 SENSOR CO AIR TEMP AND PIPE TEMP 1 CWA50C282...

Страница 188: ...188 19 2 3 CU E18NKE CU E21NKE Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts ...

Страница 189: ...R TEMP AND PIPE TEMP 1 CWA50C2656 o 30 SENSOR CO PIPING AIR TEMP 1 CWA50C2517 o 31 REACTOR 1 G0C203J00003 o 33 TERMINAL BOARD ASSY 1 CWA28K1110J o 38 ELECTRONIC CONTROLLER MAIN 1 CWA73C6407R CWA73C6408R o 40 CONTROL BOARD COVER TOP 1 CWH131333 41 CABINET SIDE PLATE LEFT 1 CWE041520A 42 HANDLE 1 CWE161010 43 CABINET SIDE PLATE CO RIGHT 1 CWE041555A 45 CABINET FRONT PLATE CO 1 CWE06K1077 46 WIRE NET...

Отзывы: