![Panasonic CS-E12HKEA Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/panasonic/cs-e12hkea/cs-e12hkea_service-manual_256778034.webp)
34
13 Servicing Mode
13.1. Auto Switch Operation
The below operations will be performed by pressing the “AUTO” switch.
1. AUTO OPERATION MODE
The Auto operation will be activated immediately once the Auto Switch is pressed and release before 5 sec..
2. TEST RUN OPERATION (FOR PUMP DOWN/SERVICING PURPOSE)
The Test Run operation will be activated if the Auto Switch is pressed continuously for more than 5 sec. to below 8 sec..
A “beep” sound will occur at the fifth sec., in order to identify the starting of Test Run operation.
3. HEATING TRIAL OPERATION
Press the AUTO switch continuously for more than 8 sec. to below 11 sec. and release when a “beep, beep” sound is heard at
eight sec. (However, a “beep” sound is occurred at fifth sec.) then press remote controller “A/C Reset” button once. Remote
controller signal will activate operation to force heating mode.
4. REMOTE CONTROLLER RECEIVING SOUND ON/OFF
The ON/OFF of remote controller receiving sound can be change over by following steps:
a. Press the AUTO switch continuously for more than 16 sec. to below 21 sec. a “beep, beep, beep, beep” sound will occur
at the sixteenth sec..
b. Press the “A/C Reset” button once. Remote controller signal will activate the remote controller sound setting mode.
c. Press the “Check” button once at remote controller. A “beep” sound will occur.
d. Press the AUTO switch once to select remote controller receiving sound ON/OFF. A “beep” sound indicates receiving
sound ON, and a long “beep” sound indicates receiving sound OFF.
13.2. Indicator Panel
Note:
• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation mode judgment, or
ON timer sampling.
• If Timer LED is blinking, there is an abnormality operation occurs.
• If Ionizer, LED is blinking, there is an abnormality of Ionizer occurs.
LED
POWER
TIMER
QUIET
POWERFUL
ION
ALLERGEN BUSTER
Color
Green
Orange
Orange
Orange
Green
Blue
Light ON
Operation ON
Timer Setting ON
Quiet Mode ON
Powerful Mode ON
Ion Mode ON
Operation ON
Light OFF
Operation OFF
Timer Setting OFF
Quiet Mode OFF
Powerful Mode OFF
Ion Mode OFF
Operation OFF
Содержание CS-E12HKEA
Страница 10: ...10 5 Dimensions 5 1 Indoor Unit ...
Страница 11: ...11 5 2 Outdoor Unit ...
Страница 13: ...13 7 Block Diagram ...
Страница 14: ...14 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Страница 15: ...15 8 2 Outdoor Unit ...
Страница 16: ...16 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Страница 17: ...17 9 2 Outdoor Unit ...
Страница 18: ...18 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Страница 19: ...19 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Panel ...
Страница 20: ...20 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board ...
Страница 23: ...23 3 For the embedded piping This can be used for left rear piping and left bottom piping also ...
Страница 39: ...39 ...
Страница 40: ...40 15 2 Indoor Cross Flow Fan and Fan Motor ...
Страница 41: ...41 ...
Страница 43: ...43 16 Technical Data 16 1 Operation Characteristics 16 1 1 CS E9HKEA CU E9HKEA ...
Страница 44: ...44 ...
Страница 45: ...45 ...
Страница 46: ...46 ...
Страница 47: ...47 16 1 2 CS E12HKEA CU E12HKEA ...
Страница 48: ...48 ...
Страница 49: ...49 ...
Страница 50: ...50 ...