13 Servicing Mode
13.1. Auto OFF/ON Button
• The “Auto OFF/ON Button” (behind the front grille) is used to operate the air conditioner if remote control is misplaced or mal-
functioning.
• Forced cooling operation is possible by pressing the “Auto OFF/ON Button” for more than 5s where “beep” sound is heard then
release the button.
• User able to select remote control transmission code and toggle remote control signal receiving sound under various setting
mode.
• To enter various setting mode:
- Press the “Auto OFF/ON Button” continuously for 5s (beep sound is heard) and release.
- Within 20s, press the “Auto OFF/ON Button” continuously for 5s again (2 beep sound is heard) and release.
- Various setting mode has limit up to 20s. Then return to normal operation.
13.1.1. Toggle Remote Control Signal Receiving Sound
• Under various setting mode, press the “Auto OFF/ON Button” to toggle the remote control sound.
- Short “beep”: Turn ON remote control signal receiving sound.
- Long “beep”: Turn OFF remote control signal receiving sound.
• After “Auto OFF/ON Button” is pressed, the 20s counter for various setting mode is restarted.
13.1.2. Select Remote Control Transmission Code
• There are 4 type of remote control transmission code could be selected and stored in EEPROM of indoor unit. The indoor unit
will only operate when received signal with same transmission code from remote control. This could prevent signal interference
when there are 2 or more indoor unit installed nearby together.
• To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
• Under various setting mode, after select the transmission code combination of remote control, press any button of remote control
to transmit a signal to indoor unit. The transmission code will be stored in EEPROM.
• After signal is received, the various setting mode is cancelled and return to normal operation.
Remote Control Printed Circuit Board
Transmission Code Combination
J-A
J-B
Remote Control No.
* Short
Open
A (default)
Open
Open
B
Short
Short
C
Open
Short
D
Содержание CS-C28GKF
Страница 9: ...9 5 Dimensions 5 1 Indoor Unit ...
Страница 10: ...10 5 2 Outdoor Unit ...
Страница 11: ...11 6 Refrigeration Cycle Diagram ...
Страница 12: ...12 7 Block Diagram ...
Страница 13: ...13 8 Wiring Connection Diagram ...
Страница 14: ...14 9 Electronic Circuit Diagram ...
Страница 15: ...15 10 Printed Circuit Board 10 1 Main Printed Circuit Board ...
Страница 16: ...16 ...
Страница 17: ...17 10 2 Power Printed Circuit Board ...
Страница 18: ...18 10 3 Indicator panel ...
Страница 21: ...21 3 For the embedded piping This can be used for left rear piping and left bottom piping also ...
Страница 46: ...46 ...
Страница 47: ...47 ...
Страница 48: ...48 15 2 Indoor Fan Motor and Cross Flow Fan Removal Procedures ...
Страница 49: ...49 ...
Страница 50: ...50 16 Technical Data 16 1 Thermostat Characteristics 1 Characteristics of thermostat ...
Страница 51: ...51 16 2 Operation Characteristics ...
Страница 52: ...52 ...
Страница 54: ...54 ...