67
•
Error Detection Control
When e-ion indicator blink, it indicates error listed below:
o
Active e-ion Air Purifying system PCB main connector open:
Judgment
Method
•
During e-ion operation (include during Patrol operation), Active e-ion Air Purifying system main
connector to PCB is opened.
Troubleshooting
Methods
•
Connect the connector or stop operation (include during Patrol operation) to cancel the blinking.
o
Abnormal Discharge error:
Judgment
Method
•
During e-ion operation, feedback voltage is-Lo (at microcontroller) is detected, it is judged abnormal
discharge and stops power supplies to the Active e-ion Air Purifying system.
•
Abnormal discharge is caused by ionizer or filter’s high voltage power supply short-circuits due to
water or dust adhesion, and so forth.
•
When abnormal discharge occurred, every 30 minutes the unit supplies power to the Active e-ion Air
Purifying system.
•
When abnormal discharge occurs for 24 times continuously, e-ion indicator blinks (not applicable for
e-ion Check Mode, where the error will shows immediately despite the 24 times counter)
Troubleshooting
Method
•
Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation and check the Active e-ion
Air Purifying system main connector to PCB.
•
After that, press “e-ion” button again to confirm the e-ion indicator not blinking.
•
The 24 times counter will be clear after 10 minutes of normal operation or when operation stops.
Error
Reset
Method
•
Press “OFF/ON” button to OFF the operation.
•
Press AUTO OFF/ON button at indoor unit to OFF the operation.
•
OFF Timer activates
•
Power supply reset
o
Active e-ion Air Purifying system breakdown error:
Judgment
Method
•
When hi-feedback voltage (at microcontroller) supplied to filter during e-ion stop, Active e-ion Air
Purifying system breakdown error shows immediately.
•
It is due to indoor PCB or filter’s high voltage power supply damage.
•
Operations except e-ion continue. Both Timer indicator and e-ion indicator blink.
Troubleshooting
Method
•
Press “PATROL/e-ion” button or “OFF/ON” button to stop the operation.
•
Change main circuit board or filter’s high voltage power supply.
•
When lo-feedback voltage supplied to Active e-ion Air Purifying system during e-ion operation, e-ion
indicator and Timer indicator stop blinking.
Содержание CS-C12KKF-2
Страница 10: ...10 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Страница 11: ...11 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C12KKF 2 ...
Страница 12: ...12 5 1 2 CS C18KKF 2 CS C24KKF 2 CS C28KKF 2 ...
Страница 13: ...13 5 2 Outdoor Unit 5 2 1 CU C12KKF 2 CU C18KKF 2 ...
Страница 14: ...14 5 2 2 CU C24KKF 2 CU C28KKF 2 ...
Страница 16: ...16 7 Block Diagram 7 1 1 CS C12KKF 2 CU C12KKF 2 ...
Страница 17: ...17 7 1 2 CS C18KKF 2 CU C18KKF 2 CS C24KKF 2 CU C24KKF 2 ...
Страница 18: ...18 7 1 3 CS C28KKF 2 CU C28KKF 2 ...
Страница 23: ...23 9 Electronic Circuit Diagram 9 1 CS C12KKF 2 CU C12KKF 2 ...
Страница 24: ...24 9 2 CS C18KKF 2 CU C18KKF 2 ...
Страница 25: ...25 9 3 CS C24KKF 2 CU C24KKF 2 ...
Страница 26: ...26 9 4 CS C28KKF 2 CU C28KKF 2 ...
Страница 27: ...27 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Страница 28: ...28 10 1 2 Power Printed Circuit Board 10 1 2 1 CS C12KKF 2 ...
Страница 29: ...29 10 1 2 2 CS C18KKF 2 CS C24KKF 2 CS C28KKF 2 ...
Страница 50: ...50 13 1 2 Cooling Operation Time Diagram For CS C18KK CU C18KK CS C24KK CU C24KK and CS C28KK CU C28KK ...
Страница 52: ...52 13 2 2 Soft Dry Operation Time Diagram For CS C18KK CU C18KK CS C24KK CU C24KK and CS C28KK CU C28KK ...
Страница 80: ...80 Figure 3 Figure 4 Figure 5 17 1 1 3 To remove discharge grille Figure 6 ...
Страница 82: ...82 Figure 10 Figure 11 ...
Страница 84: ...84 17 2 1 3 To remove power electronic controller Figure 14 Figure 15 Figure 16 Figure 17 ...
Страница 86: ...86 Figure 21 Figure 22 Figure 23 ...
Страница 88: ...88 17 3 1 3 To remove power electronic controller Figure 26 Figure 24 Figure 25 Figure 27 ...
Страница 90: ...90 Figure 31 Figure 32 Figure 33 ...
Страница 100: ...100 19 2 CS C18KKF 2 CU C18KKF 2 Cooling Capacity Performance Data 220V Cooling Capacity Performance Data 240V ...
Страница 101: ...101 19 3 CS C24KKF 2 CU C24KKF 2 Cooling Capacity Performance Data 220V Cooling Capacity Performance Data 240V ...
Страница 102: ...102 19 4 CS C28KKF 2 CU C28KKF 2 Cooling Capacity Performance Data 220V Cooling Capacity Performance Data 240V ...