10.
•
When connecting the piping, do not not use any existing (R22) pipes and flare nuts. Using such same may cause
abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A
materials.
•
Thickness of copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm.
•
It is desirable that the amount of residual oil is less than 40 mg/10 m. (only for models: CS/CU-V7CK, V9CK, V12CK,
W7CK, W9CK, W12CK)
11. Do not modify the length of the power supply cord or use of the extension cord, and do not share the single outlet with
other electrical appliances. Otherwise, it will cause fire or electrical shock.
1.
This equipment must be earthed. It may cause electrical shock if grounding is not perfect.
2.
Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at
surrounding of the unit, it may cause fire.
3.
Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the
furniture.
1.
Selection of the installation location and installation.
Select a installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance.
2.
Power supply connection to the room air conditioner.
Connect the power supply cord of the room air conditioner to the mains using one of the following method.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency.
In some countries, permanent connection of this room air conditioner to the power supply is prohibited.
1.
Power supply connection to the socket using a power plug.
Use an approved 15A/16A power plug with earth pin for (C12CT, A12CT, V12CT, W12CT, C18CT, A18CT, V18CT, W18CT) and
20A for (C24CT, A24CT, V24CT, W24CT) for the connection to the socket.
2.
Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for C12CT, A12CT,
V12CT, W12CT, C18CT, A18CT, V18CT, W18CT and 20A for C24CT, A24CT, V24CT, W24CT for the permanent connection. It
must be a double pole switch with a minimum 3 mm contact gap.
3.
Do not release refrigerant.
Do not release refrigerant during piping work for installation, re-installation and during repairing a refrigeration parts. Take care of the
liquid refrigerant, it may cause frostbite.
4.
Installation work.
It may need two people to carry out the installation work.
5.
Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
40
CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5
Содержание CS-A12CTP
Страница 11: ...3 Dimensions 11 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 12: ...12 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 13: ...4 Refrigeration Cycle Diagram 13 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 14: ...14 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 15: ...5 Block Diagram 15 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 16: ...16 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 17: ...6 Wiring Diagram 17 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 18: ...18 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 21: ...Cooling Operation Time Diagram 21 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 23: ...Soft Dry Operation Time Diagram 23 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 53: ...12 Technical Data 53 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 55: ...13 Exploded View 55 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 69: ...How to use electronic circuit diagram 69 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 71: ...19 1 REMOTE CONTROL 71 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...
Страница 73: ...73 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 MAICO Printed in Malaysia ...