Panasonic CS-A12CTP Скачать руководство пользователя страница 3

Indoor Unit

Sleep Mode Auto Control

• Indoor Fan operates refer to Indoor Fan

Speed.

• Operation stops after 8 hours.

Indoor Fan Speed Control

• High, Medium and Low.
• Automatic Fan Speed Mode

Heating : Fan speed varies from Me 

SSLo in accordance with
indoor heat exchanger.

Cooling : Fan rotates at Hi, Me and

SLo speed.

Soft Dry : Fan rotates at Lo- speed.

• Automatic air swing and manual adjusted

by remote control for vertical airflow.

• Manually adjusted by hand for horizontal

airflow.

Airflow Direction Control

Automatic Operation Button

• Press for < 5s to operate Automatic

operation mode.
(Used when the remote control cannot be used.)

• Press continuously for 5s or < 10s  to

operate Test Run/Pump down. “Beep”
sound will be heard at the 5th second.
(Used when test running or servicing.)

• Press continuously for 10s and above to

omit or resume the remote control signal
receiving sound. “Beep, beep” sound will
be heard at the 10th second.

AUTO

OFF / ON

Operation Indication Lamps (LED)

POWER

 

(Green) ......... Lights up in operation,

blinks in Automatic
Operation Mode judging,
deice operation and
hotstart.

SLEEP

 

(Orange) ......... Lights up in Sleep Mode

Operation.

TIMER

 (Orange) ....... Lights up in Timer

Setting.

AIR SWING

 

(Orange) ... Lights up in Auto Air

Swing Mode Operation.

Time Delay Safety Control

• Restarting is inhibited for appro. 3 minutes.

7 Minutes Time Save Control

• Cooling Operation only.

Anti-Dew Formation Control

• Anti-Dew Formation Control for indoor unit

discharge area.

Anti-Freezing Control

• Anti-Freezing control for indoor heat

exchanger. (Cooling and Soft Dry)

Random Auto Restart Control

• Operation is restarted randomly after

power failure at previous setting mode.

Operation Mode

• Heating, Cooling, Soft Dry and Automatic

Mode.

30 Minutes Time Save Control

• Heating Operation only.

Hot-Start Control

• At Heating Operation the indoor fan will

operate at SLo speed when indoor heat
exchanger temperature reaches 30°C.

Anti Cold Draft Control

• The indoor fan operates at SSLo when the

indoor heat exchanger temperature is low.
(During Heating mode thermal off)

3

CS-A12CTP CU-A12CTP5 / CS-A18CTP CU-A18CTP5 / CS-A24CTP CU-A24CTP5

Содержание CS-A12CTP

Страница 1: ...strial Corp Sdn Bhd 11969 T All rights reserved Unauthorized copying and distribution is a violation of law CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 11 Troubleshooting Guide 51 12 Technical Data 53 13 Exploded View 55 14 Replacement Parts List 56 15 Exploded View 57 16 Replacement Parts List 58 17 Exploded View 59 18 Replacement Parts List 60 19 Electronic Circuit Diagram 61 ...

Страница 2: ...h Fan Speed AUTO Automatic Fan Speed Airflow Direction Control TIMER 12 hour Timer Setting AIR SWING AUTO Automatic Airflow Direction Control MANUAL Airflow Direction Manual Control Heating Cooling Soft Dry Operation Temperature Setting 16 C to 30 C Automatic Operation Operation with 2 C higher than standard temperature Operation with standard temperature Operation with 2 C lower than standard tem...

Страница 3: ...Indication Lamps LED POWER Green Lights up in operation blinks in Automatic Operation Mode judging deice operation and hotstart SLEEP Orange Lights up in Sleep Mode Operation TIMER Orange Lights up in Timer Setting AIR SWING Orange Lights up in Auto Air Swing Mode Operation Time Delay Safety Control Restarting is inhibited for appro 3 minutes 7 Minutes Time Save Control Cooling Operation only Anti...

Страница 4: ...es to 15 5 C For Over heating Protection the Fan is switched ON or OFF depending on the piping temperature and the outdoor temperature A12CT 6 pole induction motor 1 speed CU A18CTP5 CU A24CTP5 4 Way Valve Control When the unit is switched to OFF during Heating Operation 4 way valve stays at Heating position for 5 minutes Overload Protection Control Outdoor fan stops when indoor heat exchanger tem...

Страница 5: ... Running Current A Cooling 5 1 5 2 Heating 5 0 5 1 EER W W 3 23 3 03 COP W W 3 70 3 51 Starting Current A 16 9 Piping Connection Port Flare piping inch inch G Half Union 1 2 L Half Union 1 4 G 3 way valve 1 2 L 2 way valve 1 4 Pipe Size Flare piping inch inch G gas side 1 2 L liquid side 1 4 G gas side 1 2 L liquid side 1 4 Drain Hose Inner diameter mm 20 Length m 0 6 Power Cord Length Number of c...

Страница 6: ... SUNISO 4GSI 410 Refrigerant R 22 g oz 920 32 5 Thermostat Electronic Control Protection Device Overload Protector Capillary Tube Length mm Cooling 630 Heating 455 Flow Rate l min Cooling 6 5 Heating 13 6 Inner Diameter mm Cooling 1 2 Heating 1 5 Air Filter Material Style P P Honeycomb Capacity Control Capillary Tube Compressor Capacitor µF VAC 30 µF 370VAC Fan Motor Capacitor µF VAC 1 5 µF 440VAC...

Страница 7: ...rent A Cooling 8 8 9 0 Heating 8 8 9 0 EER W W 2 80 2 62 COP W W 3 17 2 97 Starting Current A 44 Piping Connection Port Flare piping inch inch G Half Union 1 2 L Half Union 1 4 G 3 way valve 1 2 L 3 way valve 1 4 Pipe Size Flare piping inch inch G gas side 1 2 L liquid side 1 4 G gas side 1 2 L liquid side 1 4 Drain Hose Inner diameter mm 20 Length m 0 6 Power Cord Length Number of core wire m 1 8...

Страница 8: ...ry Tube Refrigeration Oil c c SUNISO 4GDID or ATMOS M60 700 Refrigerant R 22 kg oz 1 55 54 7 Thermostat Electronic Control Mecha Control Protection Device Inner Protector Capillary Tube Length mm 680 Flow Rate l min 11 5 Inner Diameter mm 1 5 Air Filter Material Style P P Honeycomb Capacity Control Capillary Tube Compressor Capacitor µF VAC 50 µF 370VAC Fan Motor Capacitor µF VAC 1 5 µF 440VAC 3 0...

Страница 9: ...oling 12 7 13 0 Heating 13 3 13 6 EER W W 2 46 2 34 COP W W 2 76 2 62 Starting Current A 66 Piping Connection Port Flare piping inch inch G Half Union 5 8 L Half Union 1 4 G 3 way valve 5 8 L 3 way valve 1 4 Pipe Size Flare piping inch inch G gas side 5 8 L liquid side 1 4 G gas side 5 8 L liquid side 1 4 Drain Hose Inner diameter mm 20 Length m 0 6 Power Cord Length Number of core wire m 1 8 3 2 ...

Страница 10: ... Tube Refrigeration Oil c c SUNISO 4GDID or ATMOS M60 1 130 Refrigerant R 22 kg oz 2 23 78 7 Thermostat Electronic Control Mecha Control Protection Device Inner Protector Capillary Tube Length mm 690 Flow Rate l min 20 0 Inner Diameter mm 1 9 Air Filter Material Style P P Honeycomb Capacity Control Capillary Tube Compressor Capacitor µF VAC 50 µF 370VAC Fan Motor Capacitor µF VAC 3 0 µF 440VAC 3 0...

Страница 11: ...3 Dimensions 11 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 12: ...12 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 13: ...4 Refrigeration Cycle Diagram 13 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 14: ...14 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 15: ...5 Block Diagram 15 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 16: ...16 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 17: ...6 Wiring Diagram 17 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 18: ...18 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 19: ...l start automatically if it has stopped for 7 minutes even if the room temperature is between the compressor ON temperature and OFF temperature If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and indoor heat exchanger is 2 5 C or less for 2 minutes compressor will stop and restart automatically Time Delay Safety Control is valid...

Страница 20: ... Safety Control is valid If the above phenomenon is repeated for 3 times the compressor will stop totally The above phenomenon is reset when there is a change to heating mode or stopped by Remote Control Switch When Automatic Fan Speed is selected at Remote Control during cooling operation Fan speed rotates in the range of Hi to Me 20 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 21: ...Cooling Operation Time Diagram 21 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 22: ...ft Dry operation is turned off it stops for 6 minutes Once the compressor stops it will not start for 3 minutes during Cooling operation Same as Anti Freezing Control for Cooling Mode operation For Soft Dry region 6 minutes waiting is valid during compressor stops Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation For Soft Dry region 6 minutes waiting is valid during...

Страница 23: ...Soft Dry Operation Time Diagram 23 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 24: ... of the Outdoor Heat Exchanger less than 3 C Outdoor Fan is ON The Outdoor Fan stop when Outdoor Heat Exchanger temperature is Tb or more according to Outdoor Air Temperature region as table below The Outdoor Fan restarts when the indoor heat exchanger temperature falls to 49 C During starting of Heating mode and after deice Outdoor Fan ON for 90 sec b Compressor high pressure protection If the in...

Страница 25: ... When Heating operation starts Indoor Fan will not start until the indoor heat exchanger reaches 30 C as diagram shown Hot Start is completed when indoor heat exchanger rises to 42 C or over 4 minutes This operation is to prevent the Cold Draft during Heating mode operation The operation will start when compressor OFF Thermo OFF during Heating operation For the first 30 sec from compressor OFF The...

Страница 26: ...is selected at Remote Control during heating operation Fan speed rotates in the range of Me SLo according to the heat exchanger temperature If use Manual Fan Speed at above diagram will operate with setting Fan Speed 26 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 27: ...an stops Overload Deicing During heating operation if the outdoor Fan OFF duration due to overload control is accumulated up to 60 minutes and after compressor starts for 1 minutes deicing starts Deicing ends when 1 12 minutes after deicing operation starts 2 TRS senses the outdoor piping temperature rises to 4 C TRS OPEN 3 Deicing will not end immediately as time delay Td is valid as shown below ...

Страница 28: ...Normal Deicing Time Diagram Overload Deicing Time Diagram 28 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 29: ... will start There is no detection during Outdoor Fan stops Overload Deicing During heating operation if the outdoor Fan OFF duration due to overload control is accumulated up to 60 minutes and after compressor starts for 1 minutes deicing starts Deicing ends when a 12 minutes after deicing operation starts b The outdoor piping temperature rises to about 12 C After deicing operation compressor stop...

Страница 30: ... 16 C Heating mode will immediate operate 2 Operation mode will be determine again after 1 hour of operation if the room temperature reaches to set temperature and compressor off time is over 7 minutes 30 seconds continuously The present operation mode will be continued if the room temperature does not reach to set temperature Compressor keeps running eventhough after 1 hour from automatic operati...

Страница 31: ...oling Judgement Not Applicable Judgement Heating 23 C Above Below 23 C O O Soft Dry 23 C Soft Dry Not Applicable Judgement Judgement Heating 23 C Above Below 23 C O O Heating Cooling Judgement Not Applicable Judgement 23 C Heating 23 C Above Below 23 C Automatic Set Temperature Refer 3 as below 3 Automatic Set Temperature For each operation set temperature will automatically set as shown below How...

Страница 32: ... of JX5 Refer Circuit Diagram 7 7 Delay ON Timer Control When the Delayed ON Timer is set by using the remote control the unit will start operate slightly before the set time so that the room will reach nearly to the set temperature by the desired time For Cooling and Soft Dry mode the operation will start 15 minutes before the set time For Heating mode the operation will start 30 minutes before t...

Страница 33: ...For heating As shown in the diagram at left the blow out angle changes according to the blow out temperature Angle of the left right louver is manually adjusted 7 9 Indoor Fan Speed Control Auto Fan Speed Control When set to Auto Fan Speed the fan speed is shifted automatically between Stop to SHi depend on each operation as shown below Manual Fan Speed Control Basic fan speed adjustment 3 setting...

Страница 34: ...ter that reactor will be turn OFF through RY L and in the same time RY C will turn OFF causes starting capacitor to be OFF 2 When the unit operation ON by remote controller or thermostat OFF ON the starter kit will be functioned 3 When the unit operation OFF ON by the inner protector the starter kit will be not function mean the unit will be ON as a normal operation 34 CS A12CTP CU A12CTP5 CS A18C...

Страница 35: ... used for a long period SAFETY PRECAUTIONS Before operating please read the following Safety Precautions carefully To prevent personal injury injury to others and property damage the following instructions must be followed Incorrect operation due to failure to follow instructions will cause harm or damage the seriousness of which is classified as follow Warning This sign warns of death or serious ...

Страница 36: ... power supply Setting Temperature Press 3 to increase or decrease the temperature The temperature can be set between 16 C 30 C Recommended temperature During AUTO Operation press 3 to select Operation with 2 C higher than the standard temperature Operation with the standard temperature Operation with 2 C lower than the standard temperature Standard Temperature Cooling Model Once the Automatic Oper...

Страница 37: ...ht up To cancel this operation press once more Sleep Mode Operation Details When the room temperature reaches the set temperature the airflow volume will change to low automatically Sleep Mode Operation time is 8 hours When used together with the timer the timer has a priority Cooling Model CARE AND MAINTENANCE Cleaning the Indoor Unit and Remote Control Wipe gently with a soft dry cloth Do not us...

Страница 38: ...cooling or heating performance will be reduced and electricity cost is wasted Outdoor Unit Do not block the air outlet vents Otherwise it will lower the cooling or heating performance Timer and Sleep Mode To prevent wastage of electricity use sleep mode when sleeping or Timer when going out Avoid Direct Sunlight Keep curtains or drapes closed to avoid direct sunlight during cooling operation Press...

Страница 39: ... installation is defective it will cause water leakage electrical shock or fire 3 Use the attached accessories parts and specified parts for installation Otherwise it will cause the set to fall water leakage fire or electrical shock 4 Install at a strong and firm location which is able to withstand the set s weight If the strength is not enough or installation is not properly done unit will drop a...

Страница 40: ...nit and select a location for easy maintenance 2 Power supply connection to the room air conditioner Connect the power supply cord of the room air conditioner to the mains using one of the following method Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency In some countries permanent connection of this room air conditioner to the p...

Страница 41: ...cles OUTDOOR UNIT If an awning is built over the unit to prevent direct sunlight or rain be careful that heat radiation from the condenser is not obstructed There should not be any animal or plant which could be affected by hot air discharged Keep the spaces indicated by arrows from wall ceiling fence or other obstacles Do not place any obstacles which may cause a short circuit of the discharged a...

Страница 42: ...tion on the wall The centre of installation plate should be at more than 710 mm at right and left of the wall The distance from installation plate edge to floor should more than 425 mm From installation plate left edge to unit s left side is 76 mm From installation plate right edge to unit s right is 76 mm 1 Mount the installation plate on the wall with 3 screws or more If mounting the unit on the...

Страница 43: ...door unit installation 1 Remove the Front Grille Remove 2 screws from the left and right corners Pull the upper left and right side of the intake grille toward you and it will stop at slightly tilted position Remove 2 screws Remove 3 screws cap then remove 3 screws Release 3 hooks as shown in the diagram Lift up the front grille 2a For installation on the ceiling 2b For installation on the wall 9 ...

Страница 44: ...nto two slots on the chassis and secure it to the chassis with the screw 9 2 6 PIPING AND DRAINAGE Cut off the Chassis with a nipper according to the inner surface for the Pipings Align the center of the pipings and sufficiently tighten the flare nut with fingers Finally tighten the flare nut with torque wrench ensure the direction for tightening follows the arrow on the wrench Wrap the tube joini...

Страница 45: ... 1 Align the center of the pipings and sufficiently tighten the flare nut with fingers 2 Finally tighten the flare nut with torque wrench until the wrench clicks When tightening the flare nut with torque wrench ensure the direction for tightening follows the arrow on the wrench Pipe size Torque Liquid Side 1 4 18 N m Gas Side 1 2 55 N m Gas Side 5 8 65 N m 9 3 OUTDOOR UNIT 9 3 1 SELECT THE BEST LO...

Страница 46: ...mHg 0 1 MPa Then evacuate the air approximately ten minutes 4 Close the valve at the charging set and turn off the vacuum pump Make sure that the needle in the gauge does not move after approximately five minutes Note BE SURE TO TAKE THIS PROCEDURE IN ORDER TO AVOID REFRIGERANT GAS LEAKAGE 5 Disconnect the charging hose from the vacuum pump and from the service port of the 3 way valve 6 Tighten th...

Страница 47: ...until it stops 2 Air Purging The air which contains a moisture is remaining in the Refrigeration cycle may cause a malfunction on the Compressor 1 To purge the air push the pin on the Gas side 3 way valve for three seconds using with a Hexagonal wrench and set it free for one minute Repeat this three times 2 To balance the refrigerant close the low pressure side valve on the Manifold gauge and rel...

Страница 48: ...e drain water freezes and the fan will not rotate 1 Tape the Pipings and Connecting cable from down to up 2 From the pipings gathered by taping along the exterior wall and the trap is required to prevent water from entering the room 3 Fix the pipings onto the wall by saddle or equivalent Refer to the left side diagram 9 3 6 CONNECT THE CABLE TO THE OUTDOOR UNIT 1 Remove the control board cover fro...

Страница 49: ...sly for 10 sec and above A pep pep sound will occur at the tenth sec in order to indicate the ON OFF change over of remote control receiving sound CHECK ITEMS Is there any gas leakage at flare nut connections Has the heat insulation been carried out at flare nut connection Is the connecting cable being fixed to terminal board firmly Is the connecting cable ends being clamped firmly Is the drainage...

Страница 50: ...ntrols cut a jumper wire at the remote control printed circuit board A B and cut a jumper wire at the indoor printed circuit board JX4 It is possible to select from 4 types of transmission codes including one at time of delivery condition 0 10 Servicing Information Caution Pb free solder has a higher melting point than standard solder Typically the melting point is 50 70 F 30 40 C higher Please us...

Страница 51: ...blems include insufficient insulation problem with the power source malfunction of a compressor and a fan The normal outlet air temperature and pressure of the refrigeration cycle depends on various conditions the standard values for them are shown in the table on the right 11 Troubleshooting Guide 51 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 52: ...nd 4 way valve Nature of fault Symptom Electric current during operation becomes approximately 20 lower than the normal value Insufficient compressing of a compressor The discharge tube of the compressor becomes abnormally hot normally 70 to 90 C The difference between high pressure and low pressure becomes almost zero Electric current reaches a high level abnormally and the value exceeds the limi...

Страница 53: ...12 Technical Data 53 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 54: ...7 3 83 2 38 220V Outdoor Temp C Indoor wet bulb temp 30 35 40 46 TC SHC IP TC SHC IP TC SHC IP TC SHC IP 17 0 C 5 26 3 99 1 73 4 91 3 82 1 86 4 57 3 67 1 99 4 16 3 49 2 15 19 0 C 5 30 1 89 19 5 C 5 77 4 17 1 76 5 40 4 01 1 90 5 02 3 86 2 03 4 56 3 67 2 19 22 0 C 6 29 4 33 1 80 5 88 4 16 1 93 5 47 4 01 2 07 4 97 3 83 2 23 230V Outdoor Temp C Indoor wet bulb temp 30 35 40 46 TC SHC IP TC SHC IP TC S...

Страница 55: ...13 Exploded View 55 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 56: ... COMPLETE 1 CWH40C1023 18 TAP DRAIN TRAY 1 CWH401031 19 DISCHARGE GRILLE COMPLETE 1 CWE20C2223 CWE20C2189 20 DISCHARGE GRILLE 1 CWE201046 21 VANE AIR SWING 1 CWE241124 22 CONNECTING BAR 2 CWE261052 23 CONNECTING BAR 2 CWE261053 24 VANE 14 CWE241126 O 25 AIR SWING MOTOR 1 CWA981085 O 26 INDICATOR COMP 1 CWE39C1069 27 LEAD WIRE INDICATOR 1 CWA67C4433 28 CONTORL BOARD CASING ASSY 1 CWH13K1009 31 INTA...

Страница 57: ...ew Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts 57 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 58: ...DS371306CPNA 30µF 370VAC 0 26 HOLDER CAPACITOR 1 CWH30057 27 CAPACITOR FAN MOTOR 1 CWA31618 2 0µF 450VAC 0 28 CABINET SIDE PLATE L 1 CWE041031A 29 CABINET SIDE PLATE R 1 CWE041033A 30 CABINET FRONT PLATE 1 CWE06K1034 31 WIRE NET 1 CWD041023A 32 CABINET TOP PLATE 1 CWE031014A 33 PLATE C B COVER 1 CWH131088 34 CONTROL BOARD COVER 1 CWH131092 35 HANDLE 1 CWE161010 36 OPERATION INSTRUCTIONS 1 CWF56386...

Страница 59: ...ew Note The above exploded view is for the purpose of parts disassembly and replacement The non numbered parts are not kept as standard service parts 59 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 60: ...43C2005 0 21 TERMINAL COVER 1 CWH171012 22 NUT TERMINAL COVER 1 CWH7080300 23 CONTROL BOARD 1 CWH10K1019 24 CAPACITOR FAN MOTOR 1 F0GAH305A002 0 25 CAPACITOR COMPRESSOR 1 DS371506CPNA 0 26 HOLDER CAPACITOR 1 CWH30060 27 TERMINAL BOARD ASS Y 1 CWA28K1021 28 ELECTRONIC CONTROLLER 1 CWA743072 30 SENSOR COMPLETE 1 CWA50C618 31 HOLDER SENSOR 1 CWH32089 32 CABINET FRONT PLATE 1 CWE06K034B 33 CABINET REA...

Страница 61: ... 01µ C20 0 01µ R12 10k R59 1k R30 150k R09 10k C03 0 01µ C23 0 01µ R58 10k R56 10k 4 7k 10k b e c Q01 C02 0 01µ C08 0 1µ AIR SWING MOTOR 16 1 14 15 3 2 8 a b c g f e d 9 5 12 6 11 7 10 4 13 RY PWR RY HOT R44 43 2W R43 43 2W A52A2003GR 3 1 RS D0 D1 R B CS SK 4 Vcc GND JX5 IC02 2 6 8 5 7 X01 4 00MHz 47pF x 2 R55 10k R60 R61 C101 22µF 10V R103 1k R102 1k R101 1k IC101 A742945 BZ101 BZ AUTO SW101 D101...

Страница 62: ... 50 49 48 47 40 39 38 37 36 35 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 P70 P67 P66 P72 P73 P71 P65 P64 P63 P62 P61 P60 P54 P52 P51 P53 34 10 R70 1k R69 1k R68 1k R38 R37 C15 0 01µ C27 0 1µ D12 D11 D10 D09 D08 D07 D06 D05 R26 R25 R24 R23 R22 R21 R20 R19 R27 24k R66 10k R71 1k R08 1k R28 1k R73 1k R72 1k C19 0 1µ R10 10k R29 10k TEST R32 20k C04 0 1µ SC...

Страница 63: ...1 C21 10µ 50V Q05 Q06 4 7k 10k b e c SSR02 1 3 2 CN FB PH3 R47 1 82k D13 D14 CT01 SSR02 ZNR02 RY HOT C07 10µ 50V C09 100µ 16V 3 4 1 2 PC02 C10 0 1µ C24 0 1µ C06 0 01µ R34 51k IC03 R35 10k R46 47k2W R45 47k2W c e b Q04 R06 4 7k R04 3 9k R05 820 3 4 1 2 PC01 R33 15k C05 0 1µ 5V O G I IC04 12V O G I C18 220µ 16V C16 470µ 25V C17 3300µ 35V DB01 T01 4 7 5 1 R03 510 R02 39k 2W R36 1k 63 CS A12CTP CU A12...

Страница 64: ...H R01 39k 2W SSR01 ZNR03 511U OUTDOOR UNIT TERMINAL INDOOR UNIT TERMINAL 1 2 3 4 1 2 3 4 COIL REVERSING VALVE ELECTROLYTIC CAPACITOR BL B BL BL FAN MOTOR CAPACITOR CAPACITOR OVER LOAD PROTECTOR COMPRESSOR TRS BL BL 3 3 1 4 4 1 2 8 2 8 6 7 5 6 7 BL B MAGNETIC RELAY BL GR GR GR Y B B R B A R O Y B B B R B BR MAGNETIC RELAY SCHEMATIC DIAGRAM 4 4 64 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP ...

Страница 65: ...C20 0 01 R12 10k R59 1k R30 150k R09 10k C03 0 01 C23 0 01 R58 10k R56 10k 4 7k 10k b e c Q01 C02 0 01 C08 0 1 AIR SWING MOTOR 16 1 14 15 3 2 8 a b c g f e d 9 5 12 6 11 7 10 4 13 RY PWR RY HOT R44 43 2W R43 43 2W A52A2003GR 3 1 RS D0 D1 R B CS SK 4 Vcc GND JX5 IC02 2 6 8 5 7 X01 4 00MHz 47pF x 2 R55 10k R60 R61 C101 22 F 10V R103 1k R102 1k R101 1k IC101 A742945 BZ101 BZ AUTO SW101 D101 D102 D103...

Страница 66: ...51 50 49 48 47 40 39 38 37 36 35 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 9 8 7 6 5 4 3 2 1 P70 P67 P66 P72 P73 P71 P65 P64 P63 P62 P61 P60 P54 P52 P51 P53 34 10 R70 1k R69 1k R68 1k R38 R37 C15 0 01 C27 0 1 D12 D11 D10 D09 D08 D07 D06 D05 R26 R25 R24 R23 R22 R21 R20 R19 R27 24k R66 10k R71 1k R08 1k R28 1k R73 1k R72 1k C19 0 1 R10 10k R29 10k TEST R32 20k C04 0 1 SCHE...

Страница 67: ... ZD01 C21 10 50V Q05 Q06 4 7k 10k b e c SSR02 1 3 2 CN FB PH3 R47 1 82k D13 D14 CT01 SSR02 ZNR02 RY HOT C07 10 50V C09 100 16V 3 4 1 2 PC02 C10 0 1 C24 0 1 C18 220 16V C06 0 01 R34 51k IC03 R35 10k R46 47k2W R45 47k2W c e b Q04 R06 4 7k R04 3 9k R05 820 3 4 1 2 PC01 R33 15k C05 0 1 5V O G I IC04 12V O G I C16 470 25V C17 3300 35V DB01 T01 4 7 5 1 R03 510 R02 39k 2W R36 1k 67 CS A12CTP CU A12CTP5 C...

Страница 68: ...TERMINAL 1 2 3 4 1 2 3 4 BLU VLT RED BLU BLU BRW or YLW FAN MOTOR ORG WHT WHT COMPRESSOR CAPACITOR RED GRY BLK BLK BLU RED RY HOT 1 2 3 4 RY DEICE YLW COIL 4 WAYS VALVE ELECTRONIC CONTROLLER COMP VLT T01 DB02 DB01 T 2A L 250V FM2 ORG FM1 BRW ZNR03 ZNR04 ZNR02 ZNR01 CR02 RY H L RY OFF CN TH WHT SENSOR PIPE TEMP SENSOR AIR TEMP T02 AC1 WHT HOT 1 RED HOT 2 BLK DEICE GRY CAPACITOR FUSE SCHEMATIC DIAGR...

Страница 69: ...How to use electronic circuit diagram 69 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 70: ...e Waiting 1 hr 6 sec Random Auto Restart Control 0 62 sec 0 6 2 sec 4 Way Valve 5 min 30 sec After Deice Ended 30 sec 3 sec Comp OFF after deice 2 0 2 5 Hp Hotstart Delay Times 4 min 0 sec 2 0 2 5 Hp Hotstart Finish Times 2 min 0 sec 2 0 2 5 Hp Deice Operation Occurs 1 5 HP 60 min 6 sec 60 min after previous deice 4 min 24 sec Continuously 4 min Comp ON 50 sec 0 sec TRS ON continuously for 50 sec ...

Страница 71: ...19 1 REMOTE CONTROL 71 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 72: ...19 2 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD 72 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 ...

Страница 73: ...73 CS A12CTP CU A12CTP5 CS A18CTP CU A18CTP5 CS A24CTP CU A24CTP5 MAICO Printed in Malaysia ...