file:///E:/BT-S1315DA_BT-S1315DAD_BT-S1415DA_BT-S1415DAD/SVC/s0104000000.html
1.4 X-Radiation
Warnings:
The potential sources of X-Radiation in the monitor are the high voltage section and the picture tube.
When using a picture tube test jig for service, check that the jig is capable of handling 28.5 kV
without causing X-Radiation.
Note:
It is important to use an accurate, periodically calibrated high-voltage meter (electrostatic type).
1. Turn the BRIGHT and CONTRAST controls counterclockwise fully.
2. Check that the high voltage is 23.5 kV±1.5 kV. If not, immediate service and correction is
required to prevent a possibility of premature component failure.
3. To prevent an X-Radiation possibility, it is essential to use the specified picture tube.
•@