![Panasonic BT-LH900P Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/panasonic/bt-lh900p/bt-lh900p_service-manual_272920008.webp)
INF-3
2. Service menu
2-1. Service Menu Operation Method
1. While simultaneously pressing the [INPUT] and [MENU/EXIT] button and the [HD ZOOM/ ] button, switch on
the unit's power
.
2.
Press the [MENU/EXIT] button once again. The service menu appears on the LCD. Press the [
button and
[ ] button to select the item, then press [ENTER]. The screen to change the item appears.
3. Turn off the power and turn it back on to cancel a service menu display.
Setting items
Options
Content and descriptions
GPI CHECK
Checks the function of the GPI terminal.
ADC CHECK
Sets the automatic adjustment of the ADC value.
INITIALIZE
ALL/
SET UP/
HOUR METER/
GAMMA/
ADC
Initialize the each data.
ALL: SET UP and HOUR METER data.
SET UP: menu, function button, image controls data.
HOUR METER: hour meter data.
GAMMA: Not used
ADC
: Not used
TIME
Displays and clears the time on each hour meter.
OPERATION :Displays the operation time.(Can not reset)
LCD
:Displays the LCD operation time.(Can be reset)
BACKLIGHT :Displays the BACKLIGHT operation time.(Can be
reset)
BRIGHT MODE
NORMAL/
CONNECT
Controls the operation of the image controls.
NORMAL: Normal operation
CONNECT: Connects with the BACKLIGHT
ENGINEER PAGE
Not used
SOFT VER
---
Shows the version of the software.
FPGA REV
---
Shows the revision of the FPGA1.
FPGA REV
---
Shows the revision of the FPGA2.
[SERVICE MENU]
GPI CHECK
ADC CHECK
INITIALIZE
TIME
BRIGHT MODE
ENGINEER PAGE
SOFT VER.
FPGA1 REV.
FPGA2 REV.
ALL
NORMAL
1.0.10
13
14
Содержание BT-LH900P
Страница 4: ...HCD0310NYNK102 ...
Страница 28: ...BLOCK DIAGRAMS CONTENTS BLOCK DIAGRAM BLK 1 ...