5. PLD Version Upgrade Procedure
This Model uses PLDs. When you upgrade version, use the special tool, connect to the connector for writing of
each PLD, and use the PLD writing software.
Circuit board
name
Name
Ref. No.
Connector for
writing
PLD maker
FPGA1
IC6400
MAIN P.C.B.
FPGA2
IC6600
P3605(P6104)
ALTERA
5-1. PLD Version up Method 1 (ALTERA)
A. Preparation
ITEM
REMARK
CPLD WRITER
VFK1590
VFK1590P2
D-sub 25pin-25pin Cable
Straight (Male - Female), Length : Within 1meter
Version Upgrade
Software
MAX+plus II Software ver9.6 or over ver9.6
(Please access to
www.altera.com/support/software/download/sof-download_center.html
) and
select “ASAP 2” in programming software portion in order to download it.
File NAME
jcf File (Included in “vvvsi xxxx” file).
(Copy all files of the VVVSI**** which is included " *.jct " file to floppy disk)
Personal Computer
WINDOWS 95
Ò
or 98
Ò
B. Connection
1.
Connect the D-sub Cable between CN201(for ALTERA) connector of the CPLD WRITER (VFK1590) and
Personal Computer (Printer port).
2.
Connect the CPLD WRITER Cable (VFK1590P2) between the connector for writing of each PLD (refer to
below) and P2 connector of CPLD WRITER.
3.
Turn on this model and Personal Computer (Windows mode).
Figure 12-3-1 Connection for CPLD writer
PC
D-SUB 25 pins
CABLE
CONNECTOR P201
(Altera)
VFK1590
VFK1590P2G
(Altera)
CONNECTOR
CN201
(Altera)
BT-LH900P