Coaxial cable
UL Listed NEC type CM or
CL2, RG-6/U type
Recommended distance: 20 m or less
Maximum distance: 100 m
Item
Use
For communication between iris
cameras and the control unit
Solder both ends with BNC plugs.
DC power cable
14
Item number/Recommended type
UL type SVT (2 line cores) or equivalents
*1
Necessary when supplying DC power
from the control unit to iris cameras
Maximum distance: 20 m
Solder both ends of the cable with M3
screw clamp terminals.
LAN cable
UL style 1666, CSA-FT4 or equivalents
10Base-T/100Base-TX (Category 5)
*2
Necessary for communication between
the administration PC and the control
unit
Anchor bolt
M8
Necessary for mounting the control unit
over the wall with the unicorn anchor
Unicorn anchor
UC-830 or equivalents
Necessary for mounting the control unit
over the wall
■
Preparation
Prepare the following items before the installation. The necessary items and their lengths differ depending on condition.
●
Preparing the necessary items
*
2
Cables with connector covers are unusable.
Note:
When you use the GATE 1, GATE 2, and/or ALARM OUT connectors you need another cable suited for the connectors of
the external device or control unit. Use the UL style 1571 or equivalents, AWG 22 -16 wire.
*
1
Flexible Metal Conduit (According to NEC)
Total area: 823.9 mm
2
/100 % {1.277 in.
2
/100 %}
Trade size: 31.75 mm {1-1/4 in.}
Total number of
iris cameras connected
1
2
Dimension and percent area of
conduit and tubing
437 mm
2
/53 % {0.677 in.
2
/53 %}
255 mm
2
/31 % {0.396 in.
2
/31 %}