![Panasonic BMED500 - CAMERA CONTROL UNIT Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/panasonic/bmed500-camera-control-unit/bmed500-camera-control-unit_operating-instructions-manual_262651013.webp)
13
INSTALLATIONS AND SETTINGS
INSTALLATIONS
WARNING
The installations described in the figures should be made by qualified service personnel or system installers.
Caution:
This system must be installed within the protected promise in accordance with the National Electrical Code
(NFPA70), and the local authorities having jurisdiction.
■
Caution on Installation
Secure the control unit with the supplied mounting bracket to prevent vibration, dropping and injury.
Notes:
• Keep the unit:
·
in the temperature between 0 °C and 40 °C {between 32 °F and 104 °F} and the humidity between 30 % and 80 %.
• Keep the unit away from:
·
vibration. (It may cause invalid recognition or injury.)
·
noise. (for example, places near air conditioners or ventilators)
·
electricity.
• This unit is for indoor use only.
Coaxial cable (BNC)
Coaxial cable (BNC)
Camera power cable
General-purpose
power supply *
(24 V DC)
BM-ET500
(For recognition)
Camera 1
Camera 2
System Instruction (Maximum System)
OK
NG
BM-ET500
(For recognition)
In the case of Wiegand / RS-485 use
OK
NG
OK
NG
(For
enrollment)
Administration PC*
LAN
Electric lock*
Electric lock*
Door control box* Access server*
Camera 3
BM-ET500
BM-ED500
POWER
ALARM S3
S2
S1
Wiegand
or RS-485
* The use of the Administration PC was not evaluated by UL.
* The use of electric lock was not evaluated by UL.
* The use of door control box was not evaluated by UL.
* General-purpose power supply must be a UL Listed access control power limited device.