9

Introduction

Main unit

(1)

MASTER Seal (master adaptor only)

Indicates which adaptor is pre-configured as the master adaptor.

(2)

PLC Indicator

Lights to indicate that the adaptor is connected to the HD-PLC network. For 
more information, see page 13.

(3)

LAN Indicator

Lights when a LAN cable is connected to the adaptor, and flashes when 
data is being sent or received. For more information, see page 13.

(4)

MASTER Indicator

Lights when the adaptor is configured as the master. For more information, 
see page 13.

(5)

SETUP Button

Used to register the adaptor (see page 15) or test the terminal’s network 
speed (see page 12).

(6)

Mode Selector

The position of this selector during registration (see page 15) determines 
whether the adaptor is configured as the master or as a terminal.

(7)

AC IN

Connects the adaptor to AC power as well as to the HD-PLC network.

(8)

FACTORY DEFAULT RESET Button

Used to reset the adaptor and erase its registration (see page 14).

(9)

LAN Jack

Connects the adaptor to a network device, such as a broadband router, hub, 
computer, etc. (see page 11).

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

Содержание BL-PA100KT

Страница 1: ...k 8 Main unit 9 Installation Placing the adaptors 10 Connecting adaptors to network devices 11 Useful Information Testing a terminal s network speed 12 Understanding the indicators 13 Resetting an ada...

Страница 2: ...hich means you can add additional adaptors whenever you need to add a network connection in another room of the house Simple network speed testing You can confirm the speed of each adaptor s HD PLC co...

Страница 3: ...is product can be used Abbreviations This product is referred to as the adaptor in this document Trademarks Linux is the registered trademark of Linus Torvalds in the U S and other countries All other...

Страница 4: ...ar the product and is easily accessible 6 Use only the included AC cord 7 The AC cord must remain connected at all times It is normal for this product to feel warm during use 8 To prevent the risk of...

Страница 5: ...s on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point...

Страница 6: ...electrical devices emit electrical noise If this noise is passed on to the electrical wiring in your home it may interfere with the performance speed and reliability of your adaptors For best results...

Страница 7: ...e following situations If you are concerned that another adaptor may have been accidentally registered to your master for example the adaptor of someone who lives in the same apartment building as you...

Страница 8: ...rk devices computers network printers network cameras etc When you re finished your network devices will be able to access the internet as well as each other Example of an integrated HD PLC network Ma...

Страница 9: ...e adaptor is configured as the master For more information see page 13 5 SETUP Button Used to register the adaptor see page 15 or test the terminal s network speed see page 12 6 Mode Selector The posi...

Страница 10: ...fore placing them where you plan to use them 1 Connect the AC cord of each adaptor to a wall outlet near where you plan to use it 2 Confirm that the PLC indicator of each adaptor lights in blue when y...

Страница 11: ...network 1 Confirm that each adaptor s AC cord is connected to the adaptor and plugged into a wall outlet 2 Connect a LAN cable sold separately to each adaptor s LAN jack The LAN indicator of each adap...

Страница 12: ...onnect the terminal to a different wall outlet and repeat the test Note At least one indicator Good network speed must be lit in order to use the terminal If you are not satisfied with the speed test...

Страница 13: ...stration Try again Red lit The adaptor is not functioning properly and cannot communicate over the HD PLC network Contact an authorised Panasonic service centre Off The adaptor is not plugged in The a...

Страница 14: ...e master You are registering an adaptor Note Resetting a terminal erases its registration to the master It must be registered to the master again in order to be used If the master is reset all termina...

Страница 15: ...TORY DEFAULT RESET button on the terminal for about 3 seconds see page 14 Check the position of the adaptor s mode selector see page 9 and make sure that you reset the terminal adaptor not the master...

Страница 16: ...ance issue is solved 1 Confirm that the AC cords of both the master and terminal adaptor are connected to the wall outlet If an adaptor s LAN indicator is not lit the adaptor is not receiving power 2...

Страница 17: ...the device to a different wall outlet does not resolve the performance issue connect the device to a noise filtering power strip with an AC cord that is at least 3 m long Troubleshooting note 3 Elimin...

Страница 18: ...DP Max 70 Mbps TCP 2 Max 42 Mbps 2 Using Linux FTP Maximum recommended no of adaptors per network 3 3 Performance may be affected as more adaptors are added to the network 16 including the master Maxi...

Страница 19: ...requency band 4 28 MHz Modulation Wavelet OFDM 16 PAM 2 PAM Transmission PHY rate Max 190 Mbps 1 1 This is the theoretical maximum data transmission speed of the HD PLC standard Access method CSMA CA...

Страница 20: ...s Reserved Copyright This material is copyrighted by Panasonic Communications Co Ltd and may be reproduced for internal use only All other reproduction in whole or in part is prohibited without the wr...

Отзывы: