8
OPERATING PROCEDURES
1. Power
Set the power switch on the pan/tilt head AC adapter to
the ON position, then set POWER ON/OFF Switch
w
on
the control panel to the ON position.
2. Pan/tilt Limiter Setting for Pan/tilt Head
If there are obstacles around the pan/tilt head, set the
limiters to limit the operating range (pan left and right
ends, tilt up and down ends) of the pan/tilt head.
Note: The switches on the pan/tilt head have been pre-
set before shipment from the factory on the assump-
tion that the pan/tilt head would be suspended from
the ceiling. If the pan/tilt head is mounted on a
board, for example, be sure to shift the mounting
direction switches on the pan/tilt head. Unless this
is done, pan/tilt directions will be reversed and
pan/head operation limiter data cannot be properly
stored in the memory. For details on shifting these
switches, refer to INSTALLATION OF PAN/TILT
HEAD at page 13 or the Operating Instructions for
Pan/tilt Head.
M E M O R Y
P R E S E T
2
1
3
4
5
6
7
8
9
1 0
q
On the AW-RP305, select a pan/tilt head with CON-
TROL Switch
r
.
w
Left Panning Limiter
Turn the pan/tilt head to the desired left panning limit
with PAN/TILT Lever
@0
, keep MEMORY Switch
o
depressed, and simultaneously press buttons [1] and [6]
of PRESET Switch
!0
for 5 seconds or more. When the
desired limit has been set, button [5] of PRESET Switch
!0
lights.
To reset the limit, keep the MEMORY switch
o
depressed, and simultaneously press buttons [1] and [6]
of PRESET Switch
!0
again for 5 seconds or more.
When the set limit is reset, button [10] of PRESET
Switch
!0
lights.
Up tilting limiter
Preset position selection switch
Left panning
limiter
Lights on
completion
of setting.
Preset
memory
switch
Lights on
completion
of resetting
Down tilting limiter
Right panning
limiter
e
Right Panning Limiter
Turn the pan/tilt head to the desired right panning limit
with PAN/TILT Lever
@0
, keep MEMORY Switch
o
depressed, and simultaneously press buttons [4] and [9]
of PRESET Switch
!0
for 5 seconds or more. When the
desired limit has been set, button [5] of PRESET Switch
!0
lights.
To reset the limit, keep the MEMORY Switch
o
depressed, and simultaneously press buttons [4] and [9]
of PRESET Switch
!0
again for 5 seconds or more.
When the set limit is reset, button [10] of PRESET
Switch
!0
lights.
r
Up Tilting Limiter
Turn the pan/tilt head to the desired up tilting limit with
PAN/TILT Lever
@0
, keep MEMORY Switch
o
depressed, and simultaneously press buttons [2] and [3]
of PRESET Switch
!0
for 5 seconds or more. When the
desired limit has been set, button [5] of PRESET Switch
!0
lights.
To reset the limit, keep the MEMORY switch
o
depressed, and simultaneously press buttons [2] and [3]
of PRESET Switch
!0
again for 5 seconds or more.
When the set limit is reset, button [10] of PRESET
Switch
!0
lights.
t
Down Tilting Limiter
Turn the pan/tilt head to the desired down tilting limit with
PAN/TILT Lever
@0
, keep MEMORY Switch
o
depressed, and simultaneously press buttons [7] and [8]
of PRESET Switch
!0
for 5 seconds or more. When the
desired limit has been set, button [5] of PRESET Switch
!0
lights.
To reset the limit, keep the MEMORY switch
o
depressed, and simultaneously press buttons [7] and [8]
of PRESET Switch
!0
again for 5 seconds or more.
When the set limit is reset, button [10] of PRESET
Switch
!0
lights.
y
Select one pan/tilt head after another with CONTROL
Switch
r
on the AW-RP305, and set the operating
range limiters of each pan/tilt head.