20
Connections
(continued)
■
System example 1 (connection with commercially available controller,
RS-232C daisy-chain connection)
RS-232C
connector
RS-232C
connector
Commercially
available
controller
AW-HN40/AW-HN38*
Supplied AC adaptor
Supplied AC adaptor
Supplied AC adaptor
Up to 7
* You can connect up to seven cameras to a single controller.
●
Configure the service switches at the bottom of the unit.
For details on the service switches, see “Service switch settings” (page 42).
SW1
Camera address
setting (standard
serial communication)
Set to AUTO or 1 to 7.
(Set address numbers so that they do not duplicate each other.)
SW2
SW3
SW4
Communication
format
Enable standard serial communication (ON).
SW7
Communication baud
rate
Set to 9600 bps (OFF) or 38400 bps (ON) based on your commercially
available controller.
SW8
Communication
connector
Set to RS-232C (ON).
●
Configure the following items in the camera menu.
1.
Display [System] menu
[Protocol]
[Model Select].
2.
Select [SEVIHD1], [SBRC300], or [SBRCZ330] for the protocol type.