- 19 -
Mounting
Lens mounting
Use the 2/3˝ bayonet type lens (such as the
AW-LZ17MD9AG and AK-LZ20M85G), available as an
optional accessory.
Use the AW-LZ17MD9AG lens when using the
camera mounted on the pan-tilt head AW-PH360.
Lenses other than the AW-LZ17MD9AG cannot be
used.
Do not mount the camera on the AW-PH360 when
the AK-LZ20M85G is installed.
Weight balance cannot be secured.
Note
Use the lens extension cable AW-CA12T12A if your IRIS
cable is too short.
1.
Rotate the lens fixing ring knob counterclockwise and
remove the lens mount cap.
2.
Mount the lens on the camera and rotate the lens
fixing ring knob clockwise in order to fix the lens
securely.
3.
Connect the IRIS cable to the IRIS connector on the
back panel of the camera.
When the pan-tilt head has been used
Connect the remote cable of the lens to the LENS IF (1)
terminal on the pan-tilt head.
When the SDI card (AW-HHD870) is installed
without using the pan-tilt head
Connect the remote cable of the lens to the
ZOOM/FOCUS terminal of the SDI card.
IRIS cable
Remote (for zoom/focus control) cable
(When the pan-tilt head is used, connect this
cable to the pan-tilt head)
To iris
connector
To lens I/F connector of pan-tilt head
Lens fixing
ring knob
To the ZOOM/FOCUS
terminal when the SDI
card is installed without
using the pan-tilt head
The connection and installation should be done by qualified service personnel
or system installers. Refer any servicing to qualified service personnel.