Temperature (°C)
Resistance (kΩ)
40
3.615
35
4.375
30
5.326
25
6.523
20
8.044
15
9.980
10
12.443
5
15.604
0
19.70
-5
25.05
-10
32.10
-15
41.45
-20
53.92
-25
70.53
-30
93.05
-35
124.24
-40
167.82
For optional pump.
Power supply: AC230V/50Hz, <500W
Recommended part: Yonos 25/6: made by Wilo
For optional mixing valve.
Power supply: AC230V/50Hz (input open/output
close)
Operating time: 30s~120s
Recommended part: 167032: made by Caleffi
WARNING
This section is for authorized and licensed electrician/water
system installer only. Work behind the front plate secured by
screws must only be carried out under supervision of qualified
contractor, installation engineer or service person.
Network Adaptor Installation (Optional)
Remove the Control Board Cover, then
connect the cable included with this adaptor to
the CN-CNT connector on the printed circuit
board.
o
Pull the cable out of the Tank Unit so that
there is no pinching.
o
If an Optional PCB has been installed in the
Tank Unit, connect to the CN-CNT connector
of the Optional PCB.
Connection examples: H series
Without Optional PCB
With Optional PCB
Insert a flat head screwdriver into the slot on
the top of the adaptor and remove the cover.
Connect the other end of the CN-CNT cable
connector to the connector inside the adaptor.
CN-CNT cable
CN-CNT cable
Slot
Connector