Cleaning and Maintenance Instructions
RECOMMENDATIONS
Cleaning Instructions
To ensure optimal performance of the system, cleaning has to be carried out at regular intervals. Consult an authorised dealer.
• Disconnect the power supply before cleaning.
• Do not use benzine, thinner or scouring powder.
• Use only soap (pH7) or neutral household detergent.
• Do not use water hotter than 40°C.
Indoor Unit
• Do not splash with water directly.
• Wipe the unit gently with a soft dry cloth.
Water Filter
• Clean the water filter at least once a year.
Failure to do so may cause the filter to clog up, which
may lead to system breakdown.
Consult an authorised dealer.
Outdoor Unit
• Do not obstruct the air inlet and outlet vents. Failure to
do so may result in low performance or system
breakdown. Remove any obstruction to assure the
ventilation.
• When it snows, clean and remove snow around the
outdoor unit to prevent the air inlet and outlet vents from
being covered with snow.
For extended non-use
• The water inside the Domestic Hot Water Tank should be
drained.
• Disconnect the power supply.
Non serviceable criteria
Switch off power supply then please consult an authorised
dealer under the following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the Remote
Controller.
• Water leaks from the indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes excessively warm.
Maintenance
User
In order to ensure optimal performance of the units, user may inspect and clear any obstruction on the air inlet and outlet
vents of the outdoor unit.
Installer/Engineer
• In order to ensure safety and optimal performance of the units, seasonal inspections on the units, functional check of
RCCB/ELCB, field wiring and piping have to be carried out at regular intervals by authorised installer/engineer
• Specific to the Domestic Hot Water Tank, it is important to service the Water Filter Set periodically and inspect the Anode
Bar annually. The Anode Bar* which protects the tank body will corrode, depending on water quality. When diameter is
approximate 8mm, the Anode Bar must be replaced.
• Users should not try to service or replace parts of the unit.
• Contact authorised dealer for scheduled inspection.
*Anode Bar is fitted to only certain cylinders in Ireland, NOT used in the UK.
Do not press or hit the glass cover using
hard and sharp objects. Failure to do so
may cause damage to the unit.
Ensure that the water pressure is between
0.05 and 0.3 MPa (0.1 MPa = 1 bar).
In case the water pressure is out of the
above range, consult an authorised dealer.
Water pressure gauge
All in one
- Inside indoor unit
Bi-Bloc
- Inside indoor unit
Monobloc
- Inside outdoor unit
17