Panasonic AKHRP931P - RMT PANEL - AKHC930 Скачать руководство пользователя страница 15

15

Parts and their functions

R, G, B black controls [R, G, B FLARE]

Whether these controls are to be used to adjust the flare or
pedestal can be set on the menu.  They are used for the red
(R), green (G) and blue (B) black adjustments.  When the
auto black balance can be performed and the R, G or B
black control is turned, the flare or pedestal control value on
the LCD display changes.

H

DTL control [DTL]

This is used to increment or decrement (paint) the detail
control settings (H-DTL and V-DTL adjustment values which
are set on this panel’s LCD display).
By setting this panel’s DTL HD and SD switches, the effect of
the DTL control can be applied to the HDTV video output or
SDTV video output.

I

Iris joystick control range selector switch [FULL]

This is used to set the control range of the iris joystick to
FULL (when the switch lamp is lighted: from open to close).
When the switch lamp is off, the control range of the SENSE
control 

T

is used for control.

J

Auto iris switch [AUTO]

This is used to activate the auto iris function.  Its lamp lights
in the auto iris mode.
When the lamp is off, use the Iris/master pedestal control
joystick 

M

to control the lens iris.

K

IRIS

IRIS

ACTIVE

M-PEDACTIVE

ALARM

LENS

X0.8

PED

IRIS

EXT

CALL

SENSE

RANGE

PED

N

M

O

L

P

Q

R
S

V

W

U T

Tally indicators

The red tally indicator is at the top and the green tally
indicator is at the bottom.  They light when the respective
tally signals are input to the INCOM/tally connector on the
CCU.

L

Iris/master pedestal control joystick [IRIS/PED]

The iris level of the lens is adjusted by moving the joystick up
and down, and the master pedestal is adjusted by turning it.

When in the auto iris mode:

The iris can be adjusted manually.

When not in the auto iris mode:

The auto iris level is adjusted.

Since the master pedestal adjustment is independent of the
R, G and B pedestal adjustments, the R, G and B pedestal
adjustment values remain unchanged even when the master
pedestal is changed.

M

Iris active switch [IRIS ACTIVE]

This makes it possible to adjust the iris.  When its lamp is off,
the iris cannot be controlled from this panel.  If the switch is
set to ON and the iris priority is returned to this panel, the
panel can then exercise iris control.

N

Master pedestal active switch [M-PED ACTIVE]

This is used to activate the master pedestal control functions
of the joystick.  Its lamp lights when the functions are
activated.

O

Call switch [CALL]

This is pressed to call the camera.  While it is held down, the
lamp of the camera’s call switch lights and the buzzer
sounds.  After the switch is released, the buzzer stops.
If the call switch on the camera has been pressed, the lamp
of this switch remains lighted while that switch is held down.

P

Alarm display [ALARM]

This lights when optical transmission is not going
satisfactorily or when a problem has occurred in the camera,
CCU fan or power supply.

Q

Lens extender display [LENS EXT]

This lights when the setting of the lens extender is other than
1

a

.

Lighted:

The setting of the lens extender is other than 1

a

.

Off:

This indicates that the lens extender is not being
used or that the extender function is not available.

R

Lens ratio effect [

a

0.8]

This lights when the cross converter is inserted into the lens.

S

Iris sensitivity control [SENSE]

This is used to adjust the iris control range of the joystick.

T

Iris control range control [RANGE]

This is used to adjust the iris control position (shift the control
range) of the joystick.

U

Master pedestal level indicator

This indicates the master pedestal level in the range of -99 to
99.

V

Iris f-number indicator

This indicates the lens f-number.

W

R, G, B gain controls [R, G, B GAIN]

These are used for the red (R), green (G) and blue (B)
adjustments of the white balance.  When the auto white
balance can be performed and the R, G or B gain control is
turned, the gain control value on the LCD display changes.

G

Содержание AKHRP931P - RMT PANEL - AKHC930

Страница 1: ...AK HRP931P Before attempting to connect operate or adjust this product please read these instructions completely Remote Operation Panel ...

Страница 2: ...eil numérique de la classe A est conforme à la norme NMB 003 du Canada CAUTION TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE USE ONLY THE RECOMMENDED ACCESSORIES FCC Note This device complies with Part 15 of the FCC Rules To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications This equipment has been tested ...

Страница 3: ... the designated multi cable is used to connect the ROP and CCU the distance between these two components can be extended to a maximum of 50 meters Contents Overview 3 Accessories 3 Operating precautions 4 Parts and their functions 5 ROP operation panel 5 ROP connector panel 16 Connections 16 System component connections 16 Reference files 16 Calling reference files 16 Storing reference files 16 Ex...

Страница 4: ...F or above 104 F may adversely affect the internal parts Turn off the power before connecting or disconnecting the cables Do not use the ROP outdoors Maintenance Disconnect the multi cable and wipe the panels with a dry cloth To remove stubborn dirt soak a cloth in some diluted kitchen detergent and wring it out well and then wipe the panels gently Caution Avoid using benzine paint thinners and ot...

Страница 5: ... s operations are cancelled protected status when this switch is pressed while its lamp is lighted while the CCU s power and the camera s power is ON However even when the ROP ON switch lamp is off the panel s GAIN FLARE and DTL controls can be operated provided that the active indicator is lighted It is also possible to operate the iris close switch irrespective of the ROP ON switch setting provi...

Страница 6: ...ch CHARACTER This is used to set the characters to be displayed on the PM to ON or OFF 9 OPT FAN CABLE ALARM 1 2 3 1Optical transmission alarm indicator OPT ALARM This is the optical transmission warning indicator Lighted The indicator lights when the optical signals received in the transmission between the camera and CCU are too weak or when a CCU optical transmission receiver unit data error has...

Страница 7: ...D DTL OFF MODE This is used to cancel the detail enhancer function that enhances adjusts the relative hardness softness of the picture quality in the detailed parts of the HDTV video output Its lamp lights when the function is canceled SDTV detail OFF switch SD DTL OFF MODE This is used to cancel the detail enhancer function that enhances adjusts the relative hardness softness of the picture quali...

Страница 8: ... select the video signals targeted for black and white shading correction from among the R G and B signals The lamp of the selected switch lights 4Knee control switch KNEE CONTROL This is selected to adjust the knee slope and knee point When it is selected its lamp lights The menu is two tiered the adjustment items for the knee point are displayed on the first tier and the adjustment items for the...

Страница 9: ... where the white balance was attained in the range of 800 to 800 After the white balance is adjusted 0 is set as the adjustment value VDTL Vertical detail level This is used to adjust the amount of vertical detail HDTL Horizontal detail level This is used to adjust the amount of horizontal detail CRSP Crisp This is used to set the maximum amplitude of the very faint noise components which are remo...

Страница 10: ... to set whether or not to apply zebra to the areas where coring is applied as the skin tones to the Y signals in the PM output PHAS Skin tone area phase This is used to move the areas recognized as the skin tones in the range of 153 to 93 along the Q axis on the color vector display WIDTH Skin tone area width This is used to widen the areas recognized as the skin tones in the range of 1 to 20 alon...

Страница 11: ...ed to remove the very faint noise components below the level set from the skin tone detail components Matrix control switch MATRIX CONTROL This is pressed to change the correction amounts for the R G R B G R G B B R and B G chroma saturation R G R B G R G B 1 0 0 1 1 0 B R B G 0 0 M T X 1 2 G A I N P H A S E C y _ B 0 0 MTX 12 GAIN PHASE These are used to select the following 12 axis matrix adjust...

Страница 12: ...e R B or G shading switch has been selected ANLG CCU analog output setting This is used to set the analog output of the CCU to the HD or SD component O_SEL Output select This is used to set the analog output of the CCU to RGB or YPbPr SYNC Sync waveform addition setting This is used to select whether to add the sync waveform to the analog output TYPE Analog sync phase coarse adjustment This is use...

Страница 13: ...ene or the data in the adjustment data that can be transferred to another camera to be saved in or called from eight files that serve as scene files POWER FAN Fan power switch This is used to set the power of the camera head s fan to ON OFF or AUTO SPEED FAN Fan speed This is used to set the speed of the camera head s fan 2D M Component 2 dimensional low pass filter This is used to set whether to ...

Страница 14: ...e waveform monitor WFM and picture monitor The output mode can be changed by selecting the MSEL and MLINK settings on the fourth tier of the SYSTEM screen If MLINK is set to ON when BLACK SHADING and WHITE SHADING are to be adjusted the monitor display is also switched temporarily in linkage with the R G and B shading switches D Monitor selector switch R R R R R HDTV Y G P M SDTV Y G P M G G G G G...

Страница 15: ...d B pedestal adjustments the R G and B pedestal adjustment values remain unchanged even when the master pedestal is changed M Iris active switch IRIS ACTIVE This makes it possible to adjust the iris When its lamp is off the iris cannot be controlled from this panel If the switch is set to ON and the iris priority is returned to this panel the panel can then exercise iris control N Master pedestal ...

Страница 16: ...OP able be certain to set CCU s camera power switch to OFF This function stores data in the files containing the user s basic settings user files and calls the data from them It is also possible to call data from the file in which the initial camera settings were stored at the factory factory file Calling reference files 1Factory file Press scene file switch 4 while holding down CALL The file call...

Страница 17: ...ENS X0 8 PED IRIS EXT CALL SENSE RANGE G B R PED Remote Operation Panel AK HRP930P 17 Specifications External dimension drawings CCU control Control signals camera CCU control Power supply DC 12 V Tally control signals RCP control Control signals fader control Power supply DC 12 V PREVIEW control Control signals Maximum cable extension distance 50 meters Operating temperature range 32 F to 104 F 0...

Страница 18: ...os Angeles CA 90068 323 436 3500 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m EST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Panas...

Отзывы: