Parts and their functions

SCCO (SDTV): Subcarrier phase coarse adjustment

This is used to coarsely adjust the phase of the subcarrier
signal in relation to the SDTV genlock sync signal.

SCFIN (SDTV): Subcarrier phase fine adjustment

This is used to finely adjust the phase of the subcarrier
signal in relation to the SDTV genlock sync signal.

SH_H: SD/HD horizontal phase

This is used to adjust the horizontal phase of the SDTV
output and HDTV output.

SH_V: SD/HD vertical phase 

This is used to set the vertical phase of the SDTV output
and HDTV output to line 0 and line 90 (advanced by 90H
for HDTV).

VER: ROP software version

This indicates the software version of this unit.

@

FUNC control switch

DCLK: Down-conversion link

This is used to decide whether to go with the down-
conversion system control based on the AUX external
input or set the down-conversion independently.

UCLK: Up-conversion link

This is used to decide whether to go with the up-
conversion system control that is linked to the down-
conversion system or set the up-conversion
independently.

PATHO: Pathological pattern output

This is used to forcibly output the pathological pattern.

SET: Color bar setup setting

This is used to set the color bar setup.

SD14: HD SD14 output selection

This is used to set the HD SD14 output of the CCU as the
PM or normal output.

MSEL: Monitor switch selection setting

This is used to set the monitor switch selection to PM,
WFM or the PM-WFM link mode.

MLINK: Shading link setting

This is used to set whether to link the monitor when the R,
B or G shading switch has been selected.

ANLG: CCU analog output setting

This is used to set the analog output of the CCU to the HD
or SD component.

O_SEL: Output select

This is used to set the analog output of the CCU to RGB
or YPbPr.

SYNC: Sync waveform addition setting

This is used to select whether to add the sync waveform to
the analog output.

TYPE: Analog sync phase coarse adjustment

This is used to set the sync waveform to be added to the
HD analog output to binary or tri-level.

H_CO (HDTV): Horizontal sync signal phase coarse

adjustment

This is used to coarsely adjust the phase in relation to the
HDTV genlock sync signal.

H_FIN (HDTV): Horizontal sync signal phase fine

adjustment

This is used to finely adjust the phase in relation to the
HDTV genlock sync signal.

H_CO (SDTV): Horizontal sync signal phase coarse

adjustment

This is used to coarsely adjust the phase in relation to the
SDTV genlock sync signal.

H_FIN (SDTV): Horizontal sync signal phase fine

adjustment

This is used to finely adjust the phase in relation to the
SDTV genlock sync signal.

ALC: Auto iris level

This is used to adjust the auto iris level of the lens.

SPED: Auto iris speed

This is used to set the feedback speed of the auto iris.

WNDW: Auto iris window

This is used to set the image detection area window of the
auto iris.

PEAK: Peak/average setting

This is used to set the ratio between the average and peak
values of the auto iris image detection.

ALC

SPED

WNDW

PEAK

0

0

1

4

POWER

SPEED

(FAN)

ON

LOW

2D-M

2D-E

COMB

OFF

OFF

LOW

AUTO SETUP MODE

OUTSIDE FULL

MPED

FSEL

3%

FCTRY

BRIGHT

CONT

2

30

DTL

CAMNO

ON

1

BUZZ

BLACK (PAINT)

SD

FLR

<CARD>

MODE

EXE

Содержание AKHRP931P - RMT PANEL - AKHC930

Страница 1: ...AK HRP931P Before attempting to connect operate or adjust this product please read these instructions completely Remote Operation Panel ...

Страница 2: ...eil numérique de la classe A est conforme à la norme NMB 003 du Canada CAUTION TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE USE ONLY THE RECOMMENDED ACCESSORIES FCC Note This device complies with Part 15 of the FCC Rules To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications This equipment has been tested ...

Страница 3: ... the designated multi cable is used to connect the ROP and CCU the distance between these two components can be extended to a maximum of 50 meters Contents Overview 3 Accessories 3 Operating precautions 4 Parts and their functions 5 ROP operation panel 5 ROP connector panel 16 Connections 16 System component connections 16 Reference files 16 Calling reference files 16 Storing reference files 16 Ex...

Страница 4: ...F or above 104 F may adversely affect the internal parts Turn off the power before connecting or disconnecting the cables Do not use the ROP outdoors Maintenance Disconnect the multi cable and wipe the panels with a dry cloth To remove stubborn dirt soak a cloth in some diluted kitchen detergent and wring it out well and then wipe the panels gently Caution Avoid using benzine paint thinners and ot...

Страница 5: ... s operations are cancelled protected status when this switch is pressed while its lamp is lighted while the CCU s power and the camera s power is ON However even when the ROP ON switch lamp is off the panel s GAIN FLARE and DTL controls can be operated provided that the active indicator is lighted It is also possible to operate the iris close switch irrespective of the ROP ON switch setting provi...

Страница 6: ...ch CHARACTER This is used to set the characters to be displayed on the PM to ON or OFF 9 OPT FAN CABLE ALARM 1 2 3 1Optical transmission alarm indicator OPT ALARM This is the optical transmission warning indicator Lighted The indicator lights when the optical signals received in the transmission between the camera and CCU are too weak or when a CCU optical transmission receiver unit data error has...

Страница 7: ...D DTL OFF MODE This is used to cancel the detail enhancer function that enhances adjusts the relative hardness softness of the picture quality in the detailed parts of the HDTV video output Its lamp lights when the function is canceled SDTV detail OFF switch SD DTL OFF MODE This is used to cancel the detail enhancer function that enhances adjusts the relative hardness softness of the picture quali...

Страница 8: ... select the video signals targeted for black and white shading correction from among the R G and B signals The lamp of the selected switch lights 4Knee control switch KNEE CONTROL This is selected to adjust the knee slope and knee point When it is selected its lamp lights The menu is two tiered the adjustment items for the knee point are displayed on the first tier and the adjustment items for the...

Страница 9: ... where the white balance was attained in the range of 800 to 800 After the white balance is adjusted 0 is set as the adjustment value VDTL Vertical detail level This is used to adjust the amount of vertical detail HDTL Horizontal detail level This is used to adjust the amount of horizontal detail CRSP Crisp This is used to set the maximum amplitude of the very faint noise components which are remo...

Страница 10: ... to set whether or not to apply zebra to the areas where coring is applied as the skin tones to the Y signals in the PM output PHAS Skin tone area phase This is used to move the areas recognized as the skin tones in the range of 153 to 93 along the Q axis on the color vector display WIDTH Skin tone area width This is used to widen the areas recognized as the skin tones in the range of 1 to 20 alon...

Страница 11: ...ed to remove the very faint noise components below the level set from the skin tone detail components Matrix control switch MATRIX CONTROL This is pressed to change the correction amounts for the R G R B G R G B B R and B G chroma saturation R G R B G R G B 1 0 0 1 1 0 B R B G 0 0 M T X 1 2 G A I N P H A S E C y _ B 0 0 MTX 12 GAIN PHASE These are used to select the following 12 axis matrix adjust...

Страница 12: ...e R B or G shading switch has been selected ANLG CCU analog output setting This is used to set the analog output of the CCU to the HD or SD component O_SEL Output select This is used to set the analog output of the CCU to RGB or YPbPr SYNC Sync waveform addition setting This is used to select whether to add the sync waveform to the analog output TYPE Analog sync phase coarse adjustment This is use...

Страница 13: ...ene or the data in the adjustment data that can be transferred to another camera to be saved in or called from eight files that serve as scene files POWER FAN Fan power switch This is used to set the power of the camera head s fan to ON OFF or AUTO SPEED FAN Fan speed This is used to set the speed of the camera head s fan 2D M Component 2 dimensional low pass filter This is used to set whether to ...

Страница 14: ...e waveform monitor WFM and picture monitor The output mode can be changed by selecting the MSEL and MLINK settings on the fourth tier of the SYSTEM screen If MLINK is set to ON when BLACK SHADING and WHITE SHADING are to be adjusted the monitor display is also switched temporarily in linkage with the R G and B shading switches D Monitor selector switch R R R R R HDTV Y G P M SDTV Y G P M G G G G G...

Страница 15: ...d B pedestal adjustments the R G and B pedestal adjustment values remain unchanged even when the master pedestal is changed M Iris active switch IRIS ACTIVE This makes it possible to adjust the iris When its lamp is off the iris cannot be controlled from this panel If the switch is set to ON and the iris priority is returned to this panel the panel can then exercise iris control N Master pedestal ...

Страница 16: ...OP able be certain to set CCU s camera power switch to OFF This function stores data in the files containing the user s basic settings user files and calls the data from them It is also possible to call data from the file in which the initial camera settings were stored at the factory factory file Calling reference files 1Factory file Press scene file switch 4 while holding down CALL The file call...

Страница 17: ...ENS X0 8 PED IRIS EXT CALL SENSE RANGE G B R PED Remote Operation Panel AK HRP930P 17 Specifications External dimension drawings CCU control Control signals camera CCU control Power supply DC 12 V Tally control signals RCP control Control signals fader control Power supply DC 12 V PREVIEW control Control signals Maximum cable extension distance 50 meters Operating temperature range 32 F to 104 F 0...

Страница 18: ...os Angeles CA 90068 323 436 3500 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m EST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Panas...