background image

2

For Your Safety

FCC Note:
This device complies with Part 15 of the
FCC Rules. To assure continued
compliance follow the attached instal-
lation instructions and do not make any
unauthorized modifications.

This equipment has been tested and
found to comply with the limits for a Class
A digital device, pursuant to Part 15 of
the FCC Rules. These limits are de-
signed to provide reasonable protection
against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates,
uses, and can radiate radio frequency
energy and, if not installed and used in
accordance with the instruction manual,
may cause harmful interference to radio
communications. Operation of this equip-
ment in a residential area is likely to
cause harmful interference in which case
the user will be required to correct the
interference at his own expense.

1

 is the safety information.

CAUTION

CAUTION:

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE

COVER (OR BACK).

NO USER SERVICEABLE PARTS INSIDE.

REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL.

RISK OF ELECTRIC SHOCK

DO NOT OPEN

The lightning flash with
arrowhead symbol, within an
equilateral triangle, is intended to
alert the user to the presence of
uninsulated “dangerous voltage”
within the product’s enclosure
that may be of sufficient
magnitude to constitute a risk of
electric shock to persons.

The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and main-
tenance (servicing) instructions
in the literature accompanying
the appliance.

CAUTION:

TO REDUCE THE RISK OF FIRE OR
SHOCK HAZARD AND ANNOYING
INTERFERENCE, USE THE RECOM-
MENDED ACCESSORIES ONLY.

WARNING:

TO REDUCE THE RISK OF FIRE OR
SHOCK HAZARD, DO NOT EXPOSE
THIS EQUIPMENT TO RAIN OR
MOISTURE.

The serial number of this product may
be found on the bottom of the unit.

This class A digital apparatus complies
with Canadian ICES-003.
Cet appareil numérique de la classe A
est conforme à la norme NMB-003 du
Canada.

For CANADA

12 Volt Class 

II

 Power Supply Only.

(For Example: AW-PS505P)

For Your Safety

Содержание AKHRP900P - CAMERA CONTROLLER HC

Страница 1: ...Before attempting to connect operate or adjust this product please read these instructions completely and save this manual for future use Model AK HRP900P Camera Controller...

Страница 2: ...K DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER TO SERVICING TO QUALIFIED SERVICE PERSONNEL RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash with arrowhead symbol within an...

Страница 3: ...ction in the case of no swivel stand 13 Multi purpose digital camera control system configuration 1 14 Multi purpose digital camera control system configuration 2 15 Multi purpose digital camera contr...

Страница 4: ...PS505P is used for power supply Handle the unit with care If dropped or given a strong shock it may cause a trouble or accident Use the unit in a temperature range of 32oF to 104oF 0oC to 40oC If used...

Страница 5: ...5 6 7 8 9 1 Power indication LED POWER It is lighted green when the power control switch 2 is ON It goes out when the power control switch 2 is OFF 2 Power control switch POWER ON OFF With this switch...

Страница 6: ...ch is lighted while being pressed Zoom operation lever ZOOM TELE WIDE Used for zoom operation of the lens The zoom speed changes with the shifting angles of the lever With the zoom operation lever dir...

Страница 7: ...camera is output Auto white start switch AUTO WHITE With this switch pressed the white balance is automatically adjusted During the operation WHTE LED blinks and it goes out when the adjustment is nor...

Страница 8: ...itch set to AUTO the lens is shifted to auto iris mode and the iris is automatically adjusted according to the amount of light coming into the lens With the switch set to MANU the lens iris can be mov...

Страница 9: ...put connector P T CONT RJ 45 Connects the swivel stand control signal output of the pan tilt control panel AW RP301 O Monitor signal output connector Y G Pb B Pr R BNCk3 Outputs the analog signal from...

Страница 10: ...breaker operates to cut off the power in case of over current S DC12V input connector DC12V IN XLR4 pin Connects the AC adapter We recommend that the AW PS505P option is used 1 2 3 4 Controls and thei...

Страница 11: ...e operating direction does not match the indication on the panel In that case use the attached seal for proper indication U Focus adjust direction change switch FOCUS REVERSE Used to change the direct...

Страница 12: ...emote zoom focus cable to the swivel stand see the illustration below For the connection system of each unit refer to pages 14 to 16 BREAKER ZOOM FOCUS SDI OUT 1 2 1 F G L I N Pb OUT Pr SDI OUT Y VIDE...

Страница 13: ...it by turning the lens fixing ring knob clockwise 3 Connect the iris control cable to the lens connector 4 Connect the remote zoom focus control cable to the zoom focus connector on the rear panel No...

Страница 14: ...16 1 4 SHUTTER OFF SYNCRO STEP GAIN 0 S1 S2 S3 9dB 18dB AUTO WHITE BLACK GAIN BLACK AUTO M PED I R I S CHECK Multi cable 17ft AK HDMLTCA05 Camera controller AK HRP900P D SUB 15 pin D SUB 15 pin HD mo...

Страница 15: ...200 CROSS 6300 4300 ND FLTER 1 1 32 1 16 1 4 SHUTTER OFF SYNCRO STEP GAIN 0 S1 S2 S3 9dB 18dB AUTO WHITE BLACK GAIN BLACK AUTO M PED I RIS CHECK Swivel stand AW PH300A Multi purpose digital camera AK...

Страница 16: ...4300 ND FLTER 1 1 32 1 16 1 4 SHUTTER OFF SYNCRO STEP GAIN 0 S1 S2 S3 9dB 18dB AUTO WHITE BLACK GAIN BLACK AUTO M PED I R I S CHECK Swivel stand AW PH300A Multi purposedigitalcamera AK HC900P Multi c...

Страница 17: ...and change the DIP SW on the board and adjust it to the communication speed of the camera SW3 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 5 6 7 8 Change the communication report by the combination of...

Страница 18: ...How to rack mount Install the main body on the rack as shown below Remove the rack mount bracket screw when installing Rack mount bracket Attached screw Coupler Coupler fitting holes Example of Rack M...

Страница 19: ...e three screws on the bottom to remove the blank panel When installing take care so that the internal wires are not caught by the panel 3 Install the rear panel on the bottom with the three screws Scr...

Страница 20: ...F SD CARD OPERATE ALARM SCENE MODE PRE CAM BAR TEST USER1 USER2 Camera Controller TALLY MENU ON MENU SPEED ZOOM TELE WIDE FAR NEAR FOCUS 1 2 3 4 5 PRESET CC FLTER 3200 CROSS 6300 4300 ND FLTER 1 1 32...

Страница 21: ...t ND filter select CC filter select gain select shutter select lens iris auto manual select indication change zoom operation lever direction change focus adjust direction change Iris lens iris zoom fo...

Страница 22: ...22 Memo...

Страница 23: ...23 Memo...

Страница 24: ...es CA 90068 323 436 3500 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m EST 800 334 4881 24 Hr Fax 800 334 48...

Отзывы: