– 127 –
Error Codes
When an error occurs in the unit for some reason or other, the following error codes appear in
the display window.
Emergency eject
If the cassette is not ejected even when the EJECT button is pressed, use a screwdriver or oth-
er implement to push down and simultaneously turn the EMERGENCY screw. This will enable
the cassette to be ejected.
1
Turn off the power of the VTR.
2
As shown in the figure, remove the rubber cap, and fit a Phillips head screwdriver into the
cross part of the EMERGENCY screw (red).
3
While pressing on the screwdriver, continue to turn the EMERGENCY screw in the counter-
clockwise direction until the cassette moves up.
4
Take out the cassette.
5
Return the rubber cap to its original position.
|
Note
{
1. Do not turn the EMERGENCY screw unless it is an emergency.
2. Do not turn the screw in the clockwise direction. After the cassette has moved up, do not turn
the screw any further. Otherwise, the mechanism may be damaged.
3. After the cassette has moved up, the cassette holder will not lock even when it is closed.
Before closing the cassette holder, be absolutely sure to turn the power off and back on
again to reset the mechanism’s operation.
Cassette holder
EMERGENCY screw
C
B
A
Turn off the power.
Push and turn
simultaneously.
Solenoid trouble
The servo is not locked.
Condensation has occurred.
Supply reel trouble
Take-up reel trouble
Capstan trouble
Cylinder trouble
Loading trouble
8
9
A
B
C
D
E
F
Contents
Code
No.