38
TALLY / REC
BATT
VTR
SAVE
1
4
2
3
Viewfinder lamp displays
1
TALLY/REC (recording) lamp
This lights up (red) during recording. It flashes
when a problem has occurred.
For details, refer to the section on the “Warning
system” (pages 107, 108).
2
BATT (battery) lamp
This starts flashing when the battery voltage has
dropped to the level where the battery will no longer
be usable in several minutes’ time, and it lights
when the battery is no longer usable. To prevent
operation from being interrupted, replace the
battery before the battery has discharged
completely.
For details, refer to the section on the “Warning
system” (pages 107, 108).
3
(abnormal operating status warning) lamp
This lights when the unit is set to an abnormal
operating status for any of the items set to “ON” on
the “!LED” screen of the setting menu.
For details on selecting the items targeted for the
lamp display, refer to the section on “Setting the
lamp displays” (next page).
4
VTR SAVE (VTR power-saving) lamp
This lights when the VTR SAVE/STBY switch is set
to SAVE. It goes off during recording.
<Note>
In the rec pause mode, the SAVE mode is
established automatically, and the lamp lights after
the time set for the pause timer (temporary stop
time) has elapsed.
After two minutes in the play pause mode, the
SAVE mode is established automatically, and the
lamp lights.
Viewfinder pictured here is the AJ-HVF27P
(For details concerning the viewfinder, refer to
the operating intructions of the viewfinder.)
Содержание AJ-HDC27VP
Страница 1: ...AJ P Camera VTR Operating Instructions ...