60 (E)
Setup (setting) menus
SYSTEM menu
<SYSTEM>
(continued)
Item
Setting
No.
Superimposed
No.
Superimposed
Description
display
display
17
SYS H
0000
FULL
RANGE
0001
FINE
18
SYS H
0000
–3
OFFSET
0001
–2
0002
–1
0003
0
0004
1
0005
2
0006
3
19
SYS SC/H
0000
REMOTE
0001
LOCAL
30
MENU
0000
OFF
LOCK
0001
ON
The underline on the setting item denotes the initial setting.
This selects the adjustable range for SYSTEM H during when
the ENCODER REMOTE is connected.
0:
±
8
µ
sec
1: –2.0 to +2.7
µ
sec
<Notes>
• If setting operation is performed, the setting value does not
return to factory (default) setting.
• FULL operation results regardless of this item’s setting if
SYSTEM H is varied using this unit instead of the encoder
remote controller.
System phase adjustment:
0: –13.4
µ
sec
1: –8.96
µ
sec
2: –4.52
µ
sec
3: 0 sec
4: +4.52
µ
sec
5: +8.96
µ
sec
6: +13.4
µ
sec
<Note>
Factory settings will remain unchanged even if an attempt is
made to perform a setting operation.
This sets whether the system phase is to be adjusted by the
unit or from the external encoder remote controller.
0: The system phase is adjusted from the external encoder
remote controller.
1: The system phase is adjusted by the unit.
<Note>
This setting does not take effect when LOCAL has been
selected as the SYSTEM menu item No. 10 (ENCODER SEL)
setting.
This selects whether the system file lock mode is to be
engaged or released.
0: The lock is released (file data can be changed).
1: The lock is engaged (file data cannot be changed).
<Note>
Setup menu No. 00 (WFM SEL) can be changed at any time
regardless of the setting selected for this menu item.
Video output signal adjustments
The video output signal adjustments are made by selecting the SYSTEM menu item No. 10 (ENCODER SEL) and
No. 19 (SYS SC/H) settings. A control matrix of the adjustments is shown below.
Setting Item
adjusted
VIDEO LEVEL
CHROMA LEVEL
BLACK LEVEL
CHROMA PHASE
SYSTEM menu item
17: SYS H RANGE
SYSTEM menu item
11: SYS SC
12: SYS H
SYSTEM menu item
19: SYS SC/H
SYSTEM menu item
10: ENCODER SEL
LOCAL
LOCAL
REMOTE
REMOTE
Unit
Unit
Always FULL
regardless of setting
REMOTE
FULL/FINE
Unit
External encoder
remote controller
External encoder
remote controller
LOCAL