INF-39
Item Set
value
No.
SUPER
DISP.
No.
SUPER
DISP.
Setting contents and
outline function explanation
BACK
-UP
Remarks
P61
Q61
EQ STB
0
1
OFF
ON
ON/OFF setting for the automatic standby detection function
Automatic standby detection function:
When the playback envelope is not detected for several
seconds, the mode automatically shifts to standby mode (the
mode where playback processing is stopped and the VCO center
frequency is adjusted automatically).
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
Factory use only
P62
Q62
AEQ MODE
0
1
OFF
ON
Setting of the Adaptive EQ function of the adaptive equalization filter
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No Use for electrical adjustment
P63
Q63
AEQ HOLD
0
1
OFF
ON
ON/OFF setting for the function for temporary holding of adaptive
equalization control during the transitional period when the relative
speed changes.
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
Factory use only
P64
Q64
FLT MODE
0
1
OFF
ON
ON/OFF setting for the fault detection function
Fault detection function:
When the adaptive filter or the PLL drops into a divergent state
at the time of mode switching like search etc., and a status is
detected where no normal signal can be detected over a period
of 5 tracks or more, this function pulls the status of the adaptive
filter or the PLL to the initial status.
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
Factory use only
P65
Q65
PLL MONI
0
1
OFF
ON
ON/OFF setting for PLL frequency monitor control
Frequency monitor control:
When a status is detected where the playback clock frequency at
the time of mode switching during playback is outside the
permissible range set by MONI LIM PB1 for the specified time or
longer, this function automatically pulls the frequency back to the
reference frequency corresponding to the relative speed.
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
Factory use only
P66
Q66
MONI KINDSEL 1
2
3
ENV
EYEE
EYEO
Selection of monitor signal
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No Use for electrical adjustment
P67
Q67
MONI CHSEL
0
1
2
3
4
OFF
PBL
PBR
RPL
RPR
Selection of monitor channel(Head)
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No Use for electrical adjustment
P68
Q68
ECC MODE
0
1
2
ALL ON
OT OFF
AL OFF
Setting of error correction control
0: Error correction for INNER and OUTER.
1: Error correction only for INNER, but not for OUTER.
2: No error correction for INNER and OUTER.
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
P69
Q69
CONCEAL MOD 0
1
ON
OFF
Setting of error revision control
0: Error revision is performed.
1: Error revision is not performed.
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
P70
Q70
ERROR MODE 0
1
FAST
SLOW
Setting of the error sampling time
0: FAST mode
1: SLOW mode
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
P71
Q71
TRACKING
MOD
0
1
ATF
CTL
Tracking mode setting
0: ATF tracking
1: CTL tracking
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
P72
Q72
TRACKING VAL -128
|
0
|
127
-128
|
0
|
127
Offset value setting for CTL tracking
• Effective only at the time of TRACKING MOD = CTL.
• The setting is held until exit from 50M ADJUST, 25M ADJUST.
No
P73
Q73
ATF HEAD
0
1
PB
RP
Head selection for ATF tracking
0: PB head
1: RP head
No
Содержание AJ-D93MC
Страница 3: ... 3 ...
Страница 4: ... 4 AJ D93MC ...
Страница 5: ... 5 ...
Страница 6: ... 6 AJ YA93P AJ YA94G ...
Страница 8: ... 8 AJ SD93P E ...
Страница 9: ... 9 ...
Страница 10: ... 10 ...
Страница 11: ... 11 AJ YA93P AJ YA94G ...
Страница 12: ...FCD0409NTKK145E466E467 ...
Страница 31: ...INF 18 RF CUE Board COMPONENT SIDE SERVO Board COMPONENT SIDE TP6302 TP6502 TP4102 TP233 TP235 TG6001 ...
Страница 32: ...INF 19 11 INTERNAL SWITCH SETTING The switch setting on the AVIO board part of AJ YA93 is as shown below ...
Страница 65: ...INF 52 14 ERROR MESSAGES ...
Страница 66: ...INF 53 ...
Страница 67: ...INF 54 ...
Страница 68: ...INF 55 ...
Страница 110: ...MECH 32 Figure 3 35 2 Confirm this value ...