MECH-25
3-32. RP Head Sensitivity Adjustment and Sensitivity Detection (25M Mode)
SPEC.
Sensitivity 100±10 (mV/
µ
m)
!
ATF (R/P-L)
TP6701 RF/CUE
"
H SW (R/P-L)
TP233 SERVO (F1)
TEST POINT
#
GND
TG6001 RF/CUE
VTR MODE
PLAYBACK
ADJUSTMENT
SERVO Adjustment Menu: “A14 : RPL GAIN 25”
TAPE
NTSC: VFM3581KM or VFM3581KL
(PAL: VFM3681KM or VFM3681KL)
Set the LISTA software in 25M Mode. 25M and 50M mode can be changed by “0” key.
1. Set the VTR in Service Mode to open the servo menu and select the item of “A14: RPL GAIN 25” in the “SERVO
ADJUST” menu.
2. Playback a LISTA alignment tape (VFM3581KM or VFM3581KL).
3. Select the LISTA (6) ATF Error Signal Monitor so that the screen of <ATF Error Signal monitor> appears (refer
to figure 3-32-2) Then press Enter to start the software.
4. When the picture is appeared as shown in figure 3-32-3, adjust ATF Gain (A14: RPL GAIN 25) so that the “Sens.
Value:” is in the Specification. To return the main menu, press ESC key.
5. Select Lista Main Menu “(1) Sensitivity Measurement” so that the screen of <ATF Error Signal monitor> appears
(refer to 3-32-2).
6. Playback a Lista alignment tape.
7. Press “Enter” to start the Sensitivity measurement.
8. Confirm that the sensitivity value is within the specification on the <Sensitivity Measurement Finish> screen.
(refer to figure 3-32-4).
9. If it is out of specification, return to item 3.
In case “ATF Error Signal Monitor”
or “sensitivity Measurement” is selected.
Select for sensitivity detection
Select for Linearity adjustment
Select for sensitivity
adjustment
Figure 3-32-1
Figure 3-32-2
Содержание AJ-D93MC
Страница 3: ... 3 ...
Страница 4: ... 4 AJ D93MC ...
Страница 5: ... 5 ...
Страница 6: ... 6 AJ YA93P AJ YA94G ...
Страница 8: ... 8 AJ SD93P E ...
Страница 9: ... 9 ...
Страница 10: ... 10 ...
Страница 11: ... 11 AJ YA93P AJ YA94G ...
Страница 12: ...FCD0409NTKK145E466E467 ...
Страница 31: ...INF 18 RF CUE Board COMPONENT SIDE SERVO Board COMPONENT SIDE TP6302 TP6502 TP4102 TP233 TP235 TG6001 ...
Страница 32: ...INF 19 11 INTERNAL SWITCH SETTING The switch setting on the AVIO board part of AJ YA93 is as shown below ...
Страница 65: ...INF 52 14 ERROR MESSAGES ...
Страница 66: ...INF 53 ...
Страница 67: ...INF 54 ...
Страница 68: ...INF 55 ...
Страница 110: ...MECH 32 Figure 3 35 2 Confirm this value ...
Страница 114: ...MECH 36 Figure 3 37 2 Confirm this value ...