background image

 

 

 

PRIMUSBUSINESS.CA

 

PRIMUS BUSINESS SERVICES 

|

 HOSTED PBX 

|

 

PANASONIC A406 REPEATER QUICK SETUP 

GUIDE

 

Optimizing Placement of the Repeater

 

The TGP600 base unit and A406 repeater has a maximum range of 50 meters. 
However, for optimal synchronization between the base unit and the repeater, or 
between two repeaters, the devices are recommended to be placed within a 
maximum of 40m to 50m of each other. Range may vary depending on environment. 

For maximum coverage and noise-free communications, place your repeater: 

 

at a convenient, high, and central location, such as on a wall, with no 
obstructions between your phones and the repeater; 

 

away from electronic appliances such as TVs, radios, personal computers, 
wireless devices or other phones; 

 

away from radio transmitters such as external antennas of mobile phone cell 
stations (avoid putting the repeater on a bay window or near a window); 

 

away from objects that could interfere with reception such as wire fences, 
thick walls, radiators, and metal shelving. 

The repeater is for indoor use only. 

To optimize the placement of your repeater: 

1. 

Use the signal strength indicator on the TGP600/TPA60 cordless handset to 
determine a viable location where you wish to extend the range of your base 
unit. The signal strength should still be strong where the repeater will be 
placed. 
 

 

 

2. 

Once a suitable location for the repeater is found, turn on the repeater by 

connecting the AC adaptor. If the 

 indicator on the repeater turns 

red

 

or 

amber

, this indicates that the signal strength is too weak for the repeater to 

function. Re-position the repeater to a place where the indicator turns 

green

 

3. 

Check that that repeater is providing adequate coverage for your needs. 
Using the signal strength indicator on the TGP600/TPA60 cordless handset, 

Содержание A406

Страница 1: ...vices Hosted PBX service from Primus Business Services Before you Start Your Panasonic base unit and cordless phone must be setup turned on and functioning prior to installing the repeater Please refer to the Panasonic TGP600 TPA60 TPA65 Quick Setup Guide available at www primus ca hpbxguide for more information Registering the Repeater to the TGP600 Base Unit 1 Plug the AC adapter into the repeat...

Страница 2: ... repeat the step The next step must be completed within 90 seconds 3 Plug the AC adaptor of the repeater to an electrical outlet 4 On the repeater the STATUS indicator and indicator will turn amber for 2 seconds When both indicator lights turn solid green the repeater is registered to the base unit and is ready to use 5 On the base unit exit registration mode by pressing the Handset locator button...

Страница 3: ... For wall mount instructions see Panasonic DECT Repeater Installation Manual for the KX A406 available at http primus ca business hpbxguide For additional troubleshooting tips please review the Hosted PBX Small Office Basic Troubleshooting Guide available at http primus ca business hpbxguide If the configuration process was interrupted or if you need assistance please contact Primus HPBX Technical...

Страница 4: ...to the same ID On the destination repeater 1 First check the ID of the repeater you are attempting to register to destination repeater With the destination repeater turned on and functioning normally press the PROGRAM button located under the destination repeater Note the number of times the indicator flashes green This is the ID of the destination repeater one flash indicates the ID as 1 two flas...

Страница 5: ...STATUS indicator and the indicator will turn amber for 2 seconds and then the STATUS indicator will start flashing red indicating that the repeater is waiting to be found On the base unit 7 On the base unit press and hold the Handset locator button for 4 seconds until the STATUS indicator flashes red 8 Once the destination repeater finds the origin repeater the STATUS indicator on the origin repea...

Страница 6: ...tennas of mobile phone cell stations avoid putting the repeater on a bay window or near a window away from objects that could interfere with reception such as wire fences thick walls radiators and metal shelving The repeater is for indoor use only To optimize the placement of your repeater 1 Use the signal strength indicator on the TGP600 TPA60 cordless handset to determine a viable location where...

Страница 7: ...NASONIC A406 REPEATER QUICK SETUP GUIDE walk to various areas where you may be using the phone and confirm there is adequate signal strength If not you may need to adjust the position of the repeater or install another repeater to further extend coverage area ...

Страница 8: ...rate in maintenance mode 1 Press and hold the power key on the cordless handset until the background of the display screen is light grey 2 Release the power key and press and hold the talk key for about 10 seconds until the background of the display screen turns dark grey 3 Release the talk key and press the following keys in sequence Left soft key 8 1 The display will show Maintenance Mode with t...

Страница 9: ...cription of the values are as follows PS refers to the handset 6 Walk around to confirm the service area If the readings are acceptable the display will remain green If the display turns red and the signal is weak install the repeater in the area right before it starts turning red 7 Once the site survey is complete revert the handset back to normal operation First turn off the handset 8 Go into Ma...

Страница 10: ...10 PRIMUSBUSINESS CA PRIMUS BUSINESS SERVICES HOSTED PBX PANASONIC A406 REPEATER QUICK SETUP GUIDE 11 Turn the handset off and then turn it back on The handset will be in normal operation mode ...

Страница 11: ...ase unit or another repeater if connected in series Flashing Red The repeater is not registered to the base unit Off The repeater power is off Signal Strength ID Indicator Solid Green Signal strength of the base unit is strong Flashing Green The base unit is in repeater range The number of flashes indicates the current ID of the repeater When it flashes once the ID is 1 Solid Amber Signal strength...

Отзывы: