No. SX-DSV03335 - 36-
R2.0
Industrial Device Solution Business Unit, Panasonic Corporation
Size E 200 V
Pin No.
Symbol
Name
Description
XA
5
L1
Main power input
terminal
200 V
3 phase 200 - 240 V
+ 10 %
- 15 %
50/60 Hz
4
L2
3
L3
2
L1C
Control power input
terminal
200 V
Single-phase 200 - 240 V
+ 10 %
50/60 Hz
1
L2C
- 15 %
XC
4
P
Regenerative resistor
connecting terminal
Normally, short out the circuit between B and RB.
To use an external regenerative resistor (customer prepared), open between RB
and B and connect an external regenerative resistor between P and B.
In addition, parameter setting is required for the regenerative resistor.
For details, refer to "Technical Reference - Functional Specification ".
Do not connect anything to the N terminal.
3
RB
2
B
1
N
XB
3
U
Motor output terminal
Connect each phase of the motor wiring.
U
:
U phase, V
:
V phase, W
:
W phase
2
V
1
W
Earth
Earth terminal for grounding