No.SX-DSV03335
Cate
Pr.
Parameter
Default
value
Cate
Pr.
Parameter
Default
value
Cate
Pr.
Parameter
Default
value
Cate
Pr.
Parameter
Default
value
Cate
Pr.
Parameter
Default
value
0
0 For Manufacturer use
1
1 For Manufacturer use
0
2
Real-time auto-gain tuning setup
1
3
Selection of machine stiffness at real-
time auto-gain tuning
Size A-C 13
Size D-H 11
4 Inertia ratio
250
5 No use
-
6 No use
-
7 No use
-
8 For Manufacturer use
0
9 For Manufacturer use
1
10 For Manufacturer use
1
11
Numerator of pulse output
division
2500
12
Reversal of pulse output logic/
output source selection
0
13 1st torque limit
500
14
Position deviation excess setup
100000
15 For Manufacturer use
1
16
External regenerative resistor
setup
Size A,B,G,H 3
Size C-F 0
17
Load factor of external
regenerative resistor selection
0
18 For Manufacturer use
0
PARAMETER
MODEL
*1 When checking directly value of parameter-file with a text data etc., it does not show the decimal point.
Ex) Pr6.24 Load change compensation filter
・・・
Value of Panaterm
:
0.53 / Value of parameter-file
:
53
* Parameter names in the table correspond to the DD motor (rotary type). For parameter names and setting values corresponding to linear motors, refer to the technical document.
MINAS-A6B(BL/BM) series
1/11