15
Indoor
Model
CS-RZ35TKR
POS (EAN)
5025232871353
Outdoor
Model
CU-RZ35TKR
POS (EAN)
5025232871544
Dimension
Unit
Height (ID / OD)
mm (inch)
290 (11.7/16) / 542 (21-11/32)
Width (ID / OD)
mm (inch)
799 (31-15/32) / 780 (30-23/32)
Depth (ID / OD)
mm (inch)
197 (7-25/32) / 289 (11-13/32)
PCKG.
(Stacking
Condition)
Height (ID / OD)
mm (inch)
234 (9-7/32) / 603 (23-3/4)
Width (ID / OD)
mm (inch)
871 (34-5/16) / 891 (35-3/32)
Depth (ID / OD)
mm (inch)
354 (13-15/16) / 396 (15-19/32)
Weight
Net (I/D / O/D)
kg (lb)
8 (18) / 32 (71)
Gross (I/D / O/D)
kg (lb)
9 (20) / 34 (75)
Stacking No. (CS / CU / CZ)
Actual Stacking Quantity (12 / 6 / -)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch
6.35 (1/4) / 9.52 (3/8)
Standard Length
m (ft)
5.0 (16.4)
Length Range ( min - max)
m (ft)
3 (9.8) ~ 20 (65.6)
I/D & O/D Height Different
m (ft)
15 (49.2)
Additional Gas Amount
g/m (oz/ft)
10 (0.1)
Length for Additional (Gas)
m (ft)
7.5 (24.6)
Drain Hose
Inner Diameter
mm
16.7
Length
mm
650
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coat)
Fin Type
Slit Fin
Row x Stage x FPI
2 x 15 x 21
Size ( W x H x L)
mm
610 x 315 x 25.4
Outdoor Heat
Exchanger
Fin Material
Aluminium (Blue Coat)
Fin Type
Corrugated Fin
Row x Stage x FPI
2 x 24 x 17
Size ( W x H x L)
mm
36.4 x 504 x 713:684
Air Filter
Material
Polypropelene
Type
One-touch
Power Supply
Outdoor Power Supply
Power Supply Cord
NIL
Thermostat
Electronic Control
Protection Device
Electronic Control
Dry Bulb
Wet Bulb
Indoor Operation Range
Cooling
Maximum °C (°F)
32 (89.6)
23 (73.4)
Minimum °C (°F)
16 (60.8)
11 (51.8)
Heating
Maximum °C (°F)
30 (86.0)
-
Minimum °C (°F)
16 (60.8)
-
Outdoor Operation Range
Cooling
Maximum °C (°F)
46 (114.8)
26 (78.8)
Minimum °C (°F)
5 (41.0)
-
Heating
Maximum °C (°F)
24 (75.2)
18 (64.4)
Minimum °C (°F)
-15 (5.0)
-
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Specifications are subjected to change without prior notice for further improvement.
Содержание 5025232871346
Страница 36: ...36 7 Refrigeration Cycle Diagram 7 1 CS RZ25TKR CU RZ25TKR CS RZ35TKR CU RZ35TKR ...
Страница 147: ...147 Figure 9 Figure 10 ...
Страница 151: ...151 Figure 9 Figure 10 ...
Страница 153: ...153 18 3 2 CU RZ50TKR CU RZ60TKR Caution When handling electronic controller be careful of electrostatic discharge ...