PanaFlow™ MV80, MV82 & MV84 User’s Manual
157
Appendix C. Flow Meter Calculations
Appendix C. Flow Meter Calculations
C.1
In-Line Flow Meter Calculations
C.1.1
Volume Flow Rate
Qv
f
K
---
=
C.1.2
Mass Flow Rate
Q
M
Q
V
=
C.1.3
Flowing Velocity
V
f
Q
V
A
-----
=
Where:
A
= Cross sectional area of the pipe (ft
2
)
f
= Vortex shedding frequency (pulses/sec)
K
= Meter factor corrected for thermal expansion (pulses/ft
3
)
Q
M
= Mass flow rate (lbm/sec)
Q
V
= Volume flow rate (ft
3
/sec)
V
f
= Flowing velocity (ft/sec)
= Density (lbm/ft
3
)
Содержание PanaFlow MV80
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 20: ...Chapter 1 Introduction 8 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 108: ...Chapter 3 Operating Instructions 96 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 140: ...Chapter 4 Serial Communications 128 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 166: ...Appendix A Product Specifications 154 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 168: ...Appendix B Approvals 156 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 176: ...Appendix C Flow Meter Calculations 164 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 180: ...Appendix D Glossary 168 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 182: ...Warranty 170 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 183: ......