Chapter 5. Troubleshooting and Repair
138
PanaFlow™ MV80, MV82 & MV84 User’s Manual
5.5.3
Symptom: No Output (cont.)
OUTSIDE
INSIDE
OUTSIDE
Figure 123: Vortex Sensor Connector Pins
4.
With the sensor still disconnected, go to the first column of the hidden diagnostics and display the vortex
shedding frequency,
f
. Hold a finger on the three exposed pins on the analog board. The meter should read
electrical noise, 60 Hz for example. If all readings are correct, re-install the vortex sensor wires.
5.
Verify all meter configuration and troubleshooting steps previously described. There are many possible causes of
this problem. Consult Panametrics if necessary.
Содержание PanaFlow MV80
Страница 2: ......
Страница 4: ...ii no content intended for this page...
Страница 20: ...Chapter 1 Introduction 8 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 108: ...Chapter 3 Operating Instructions 96 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 140: ...Chapter 4 Serial Communications 128 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 166: ...Appendix A Product Specifications 154 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 168: ...Appendix B Approvals 156 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 176: ...Appendix C Flow Meter Calculations 164 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 180: ...Appendix D Glossary 168 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 182: ...Warranty 170 PanaFlow MV80 MV82 MV84 User s Manual no content intended for this page...
Страница 183: ......