Page 5-5
Table 1: Min and Max Capture Combinations
Combination Result
1:
Max Capture
ON and Min
Capture OFF
The gage displays the active reading and the
maximum thickness reading in Measure
mode.
2:
Max Capture
ON and Min
Capture ON
The gage displays the active reading and the
minimum thickness reading in Measure
mode. The maximum thickness reading is
captured, but not displayed unless the user
presses [2
nd
F], [MIN] from the Measure
mode. The maximum thickness value will be
displayed briefly, and then the gage will
return to displaying the active reading and
minimum reading.
3:
Max Capture
OFF and Min
Capture ON
The gage displays the active reading and the
minimum thickness reading in Measure
mode.
4:
Max Capture
OFF and Min
Capture OFF
The gage displays the active reading only in
Measure mode. Remember that the user can
turn on the Min function at any time by
using the [MIN] key from the Measurement
mode.