Panamax M5510 Скачать руководство пользователя страница 11

9

USA & Canada (800) 472-5555  •  (707) 283-5900  •  Fax (707) 283-5901

FEATURE DETAILS

SignalPerfect

A/V Signal Line Protection

In the event of a power surge, system components plugged into different AC receptacles and/or circuits can create voltage
differentials that result in "rogue" surges on the signal lines.  These "backdoor" surges can be as damaging to your equip-
ment as an externally generated surge.  Equipment that typically provides “backdoor” access for damaging surges includes,
ceiling mounted video projectors or powered subwoofers located away from the main system components.  The MAX

®

5510

provides four line-level protection circuits that are optimized for audio and video signals.  The clamping level is 6.5 VDC.
Although the circuits are individually labeled for video and audio signals (Y, PR, PB, SUB), performance is identical and they
may be used for any combination of audio or video signal lines.

Power Cord

The MAX 5510 comes equipped with a UL recognized, 10 foot, IEC320 power cord rated for 120V, 15-Amps, minimum 14
gauge wire and the cord secured to the enclosure with a cord retention bracket. The cord is not intended to be removed.

SignalPerfect

Coaxial Line Protection

Panamax’s exclusive SignalPerfect™ Technology provides application-specific protection for your satellite and cable TV
equipment.  The satellite connections are for coaxial cables connected to a DBS (single or dual LNB) satellite dish.  The
antenna connection is for a non-amplified rooftop antenna or cable TV line.  It may also be used to protect the equipment
plugged into the MAX

®

5510 from “backdoor” surges in situations where the video signal runs to another room for an addi-

tional television.

Cable TV (Including HDTV) 

– TV tuners operate at approximately 10 millivolts  (0.01 V) and utilize the frequency spec-

trum of 50Mhz to 950Mhz.  The clamping level of the MAX

®

5510’s cable TV protection circuitry is 700 millivolts (0.7 volts).

That’s less than 1 volt above normal operating levels.  The circuitry is shielded to prevent interference and has been opti-
mized to have less than 1dB of signal loss throughout the entire 50Mhz to 950Mhz range.

Satellite

- Satellite dish LNB’s can require up to 24 volts to operate and utilize the frequency range of 950Mhz to 2.2Ghz.

The clamping level of the MAX

®

5510’s satellite protection circuitry is 27 volts - just 3 volts above the maximum operating

voltage.  The circuitry is shielded to prevent interference and has been optimized to have less than 1dB of signal loss
throughout the entire 950Mhz to 2.2Ghz range.

SignalPerfect

Telephone Line Protection

Satellite TV receivers require a telephone line connection for Pay-Per-View services.  The MAX

®

5510 also provides surge

protection for this line.  One pair of RJ-11/45 compatible telephone jacks is provided for this.  The circuitry utilizes auto-
resetting PTCRs and solid-state SIDACtors™ for reliability and unsurpassed protection.  The clamping level of the MAX

®

5 5 1 0 ’s telephone protector is 260 volts.  This will allow typical ring voltage (90-130VAC) and operating battery voltage 
(-48DC) to pass through the circuit and still protect the modem in your satellite receiver from damage.

Please note

:

The protection circuitry will not work if the phone lines are reversed.  The incoming phone cable

must be connected to the "LINE" jack and the cable to the audio/video equipment must be connected to the
"EQUIP" jack.

Please note

:

All coaxial cable sheaths from outdoors must be grounded to the building grounding electrode

system where they enter the building (per applicable NEC/CEC code).  A driven ground rod is not adequate and
may be dangerous.

Содержание M5510

Страница 1: ...MAX 5510 ACRegenerator Owner s Manual 1690 Corporate Circle Petaluma CA 94954 www panamax com ...

Страница 2: ... center that meets the power quality needs for each piece of equipment in your entertainment system This is truly a Firewall for Noise With power this clean you ll wonder how you ever used your system without it Performance alone makes this a world class product but we didn t stop there The understated elegance of the MAX 5510 s styling complements and completes even the most sophisticated Audio V...

Страница 3: ...tection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Balanced vs Isolated Power 12 Frequently Asked Questions 13 TABLE OF CONTENTS USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 1 MAX 5510 ACRegenerator 1 RJ 11 Telephone Cable 3 Coax Cables for Satellite TV Cable TV and or Antennas 1 Convenience Lamp with 5W halogen ...

Страница 4: ... to you Level 2 for Analog Components The second level in the Tri Power Filtration system features two banks of independently filtered outlets 2 outlets per bank for analog components These outlet banks utilize Balanced Double L filter circuits that are far superior to any other design in filtering out all forms of electromagnetic and radio frequency interference in both common and normal modes Cr...

Страница 5: ...USA Canada 800 472 5555 707 283 5900 Fax 707 283 5901 3 CONNECTION DIAGRAM Tri Power Filtration System ...

Страница 6: ... optimized for Cable TV or non amplified Rooftop Antenna signal line protection Telephone Jacks In Out connections for telephone line or pay per view line protection Isolation Transformer Circuit Breaker Opens in the event that equipment connected to the Isolated Outlets exceeds 4 amps current draw When white is visible the breaker has opened Reduce the load and push to reset Voltmeter Backlit ana...

Страница 7: ...ear panel receptacles at the same time This will overload the lamp s power supply and cause damage not covered by the MAX 5510 s warranty 2 USE ONLY A 12V DC 5W HALOGEN BAYONET BASE ANSI T 3 REPLACEMENT BULB Use USHIO JC12V 5W BA9S or equivalent A higher rated bulb will overload the lamp power supply and cause damage not covered by the warranty 3 Make sure the protruding lamp does not interfere wi...

Страница 8: ...dition This light will flash quickly when the MAX 5510 is first plugged into the wall outlet Isolated Power Green LED When this light is ON it indicates that the Isolated Power Mode has been selected for the power supply to the digital source components Balanced Power Green LED When this light is ON it indicates that the Balanced Power Mode has been selected for the power supply to the digital sou...

Страница 9: ...lines between the power utility s generating plant and the wall outlet This contaminated power feeds the isolation trans former s primary winding and is regenerated through electromagnetic induction as clean power on the isolated secondary winding The outlets are connected to the secondary winding which has no conductive connection to the primary winding This isolates your digital source equipment...

Страница 10: ...gged into a switched outlet on the receiver may also be used if a 12VDC trigger is not built in The MAX 5510 Voltage Sense Trigger input uses standard 3 5 mm mono mini plug jacks These jacks have electrically isolated switches built in If nothing is inserted into the input jacks the voltage sense is bypassed and the MAX 5510 Switched Outlets button on the front panel controls the startup shutdown ...

Страница 11: ...V tuners operate at approximately 10 millivolts 0 01 V and utilize the frequency spec trum of 50Mhz to 950Mhz The clamping level of the MAX 5510 s cable TV protection circuitry is 700 millivolts 0 7 volts That s less than 1 volt above normal operating levels The circuitry is shielded to prevent interference and has been opti mized to have less than 1dB of signal loss throughout the entire 50Mhz to...

Страница 12: ...ge threshold 95VAC the MAX 5510 will perform the following tasks until line voltage returns to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The MAX 5510 requires line voltage to return to within the safe operating range for 10 seconds before returning to normal operating mode This is...

Страница 13: ...CTION UL 1449 Surge Suppression Rating 330V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC Max Current Rating 15A 1800 Watts Thermal Fuse YES Over Under Voltage Protection YES Over voltage shutoff threshold Response time 137 4 VAC 10 milliseconds Und...

Страница 14: ... field radiation from connected power cords through cur rent phase cancellation 1 Radiated electrical fields can still be evident but to a much lesser degree than with grounded neutral power unless the impedances from L G and N G in the connect ed equipment are equal With Balanced Power the asymmetric zero volt N G reference at the panel is replaced by a symmetric ground reference between line and...

Страница 15: ...f the lighting is turned ON or OFF If the control knob is turned OFF turn it ON and continue turning until you have reached the desired light level If the control knob is turned ON and there is no light turn the knob to maximum If you still have no light call Panamax Customer Service for help ____ I connected the 5W Convenience Lamp and the lamp will not work What is the problem 1 Check to see if ...